System Impacts
Financial Impact
Within the federal sector alone, estimates put annual expenditures for water and sewer services between $500 million and $1 billion. Similar estimates predict the government could save as much as $240 million per year through moderate gains in water efficiency and operations.1
For a high-level overview, watch DOE Better Buildings' The Business Case for High-Performance Buildings.
Findings and Case Studies
Finding: Plumbing fixture replacements yield a saving of over 25 million gallons or $271,000 annually, providing a payback of only three years.
Scope: U.S. Department of Energy Y-12 National Security Complex over 7-year period – BMP1: Water Management PlanningSource: http://energy.gov/sites/prod/files/2013/10/f3/y12_lessonslearned.pdf
Finding: Through water conservation measures water use was reduced more than 50 percent.
Scope: U.S. Army Fort Huachuca: BMP 2: Information and Education ProgramsSource: http://energy.gov/sites/prod/files/2013/10/f3/fthuachuca_watercs.pdf
Finding: Saved 179 million gallons each year, valued at $330,000 annually provided a 1.75 percent payback per year.
Scope: Kirtland Air Force Base: BMP 3 – Distribution System Audits, Leak Detection, and RepairSource: http://energy.gov/sites/prod/files/2013/10/f3/water_cs_kirtland.pdf
Finding: $30,000 in reduced wastewater fees from reclaiming cooling pond water.
Scope: Pacific Northwest National Lab: BMP 4/5Source: http://energy.gov/sites/prod/files/2013/10/f3/water_pnnl.pdf
Finding: Reduced plumbing fixture water use by thirty percent.
Scope: NASA Marshall Space Flight Center – BMP 6Source: http://energy.gov/sites/prod/files/2013/10/f3/nasa-msfc_watercs2_.pdf
Finding: Saved 1,538,000 gallon of water each year with only a project cost of $3,500, resulting in annual savings of $12,900 and a payback period of less than 2 months.
Finding: Saved 19,574 Kgal of water and 1,109,888 MBtu of energy for savings of about three million dollars in FY11.
Scope: Naval Air Station Oceana – Boiler Upgrades and Decentralizing Steam Systems – BMP 8Source: http://energy.gov/sites/prod/files/2013/10/f3/oceana_water_cs.pdf
Finding: Reduced water/sewer bill by $5,650 and electric bill by $27,399.
Scope: NASA Marshall Flight Center – BMP 10Source: http://energy.gov/sites/prod/files/2013/10/f3/nasa-msfc_watercs2_.pdf
Finding: 5.4% reduction in water consumption and 70 billion reduction in Btu, equaling $2.7 million in savings.
Scope: DoD Exchange Facilities – BMP 11Source: http://energy.gov/sites/prod/files/2013/10/f3/dodexchange_watercs.pdf
Finding: Between $2,000 and $9,200 in annual savings of water and sewer costs.
Scope: Various EPA Sites – BMP 12Source: http://energy.gov/sites/prod/files/2013/10/f3/epa_watercspdf.pdf
Finding: 18% reduction in total potable water consumption, resulting in $160,000 savings annually.
Scope: Sandia National Laboratories – BMP 13Source: http://energy.gov/sites/prod/files/2013/10/f3/water_sandia.pdf
Finding: 16% reduction in water use, or $35,000 through use of an air handler condensate recovery system.
Scope: EPA Science and Ecosystem Support Division – BMP 14Source: http://energy.gov/sites/prod/files/2013/10/f3/water_sandia.pdf
Finding: Saving $682,000 annually by offsetting over 303 million gallons with water reclamation and reuse.
Scope: U.S. Army Fort Carson – BMP 14Source: http://energy.gov/sites/prod/files/2013/10/f3/epa-scesd_watercs.pdf
Did You Know?
Within the federal sector, expenditures for water run between $0.5 billion and $1 billion.Source: Whole Building Design Guide
A typical federal employee uses 15 gallons of water per day (gpd) at work.http://www.energy.gov/sites/prod/files/2013/10/f3/waterefficiency_fedoffices.pdf
Source: http://www.nrel.gov/docs/fy02osti/31303.pdf
Federal facilities use sixty billion Btu of energy annually to process, heat, and distribute water throughout the building. Source: WBDG - Water Conservation