Architectural ID |
Title |
JPEG |
CAD |
DATE POSTED |
A-SK08-00 |
Access Panel Detail - Type - 1 |
(148KB) jpg
|
(44KB) zip
|
2/3/12 |
A-SK10-00 |
Bumper Rail Detail - Type - 1 |
(137KB) jpg |
(38KB) zip
|
2/3/12 |
A-SK10-01 |
Corner Guard Detail 01 |
(124KB) jpg
|
(36KB) zip
|
2/3/12 |
A-SK10-02 |
Corner Guard Detail 02 |
(155KB) jpg
|
(39KB) zip
|
2/3/12 |
A-SK11-00 |
Detail At Drip Groove (TYP) |
(136KB) jpg
|
(35KB) zip
|
2/3/12 |
A-SK11-01 |
Epoxy Sink Detail |
(126KB) jpg
|
(35KB) zip
|
2/3/12 |
A-SK11-02 |
Detail At Drip Groove (TYP) 02 |
(128KB) jpg
|
(34KB) zip
|
2/3/12 |
A-SK12-00 |
Peninsula Shelf Detail |
(169KB) jpg
|
(47KB) zip
|
2/3/12 |
A-SK12-01 |
Shelf Bracket Detail |
(121KB) jpg
|
(36KB) zip
|
2/3/12 |
A-SK12-02 |
Typical Countertop Detail |
(138KB) jpg
|
(39KB) zip
|
2/3/12 |
A-SK12-03 |
Typical Peninsula Casework Detail |
(206KB) jpg
|
(66KB) zip
|
2/3/12 |
to top |
|
|
|
|
Electrical ID |
Title |
JPEG |
CAD |
DATE POSTED |
|
Normal Power |
|
|
|
E-20-01 |
Interstitial Space Panel Mounting |
(160KB) jpg
|
(164KB) zip
|
1/3/13 |
|
Emergency Power |
|
|
|
E-30-01 |
Separately Derived Generator System Grounding |
(176KB) jpg
|
(142KB) zip
|
1/3/13 |
|
Site |
|
|
|
E-40-01 |
Typical Handhole Detail |
(94KB) jpg
|
(233KB) zip
|
6/27/12 |
E-40-02 |
Typical Electrical Manhole |
(123KB) jpg
|
(148KB) zip
|
6/27/12 |
E-40-03 |
Typical Communications Manhole |
(257KB) jpg
|
(176KB) zip
|
6/27/12 |
E-40-04 |
Manhole Cover Detail |
(198KB) jpg
|
(145KB) zip
|
6/27/12 |
E-40-05 |
Manhole Cable Rack Detail |
(179KB) jpg
|
(155KB) zip
|
6/27/12 |
E-40-06 |
Ductbank Section |
(211KB) jpg
|
(216KB) zip
|
6/27/12 |
E-40-07 |
4-Way Ductbank |
(199KB) jpg
|
(204KB) zip
|
6/27/12 |
E-40-08 |
6-Way Ductbank |
(213KB) jpg
|
(240KB) zip
|
6/27/12 |
E-40-09 |
10-Way Ductbank |
(240KB) jpg
|
(276KB) zip
|
6/27/12 |
E-40-10 |
12-Way Ductbank |
(248KB) jpg
|
(280KB) zip
|
6/27/12 |
E-40-11 |
Tele-LAN Ductbank Elevation |
(171KB) jpg
|
(260KB) zip
|
6/27/12 |
|
Raceways, Conduit & Boxes |
|
|
|
E-50-01 |
Vertical Busduct Floor Penetration Detail |
(180KB) jpg
|
(320KB) zip
|
1/4/13 |
E-50-02 |
Conduit Installation in Concrete Construction |
(197KB) jpg
|
(205KB) zip
|
1/4/13 |
E-50-03 |
Pipe Sleeve Thru Wall Detail |
(165KB) jpg
|
(147KB) zip
|
1/4/13 |
E-50-04 |
Caste In Place Sleeve for Raceway |
(168KB) jpg
|
(150KB) zip
|
1/4/13 |
E-50-05 |
Electrical Wiring Through Fire & Fire Smoke Barriers |
(158KB) jpg
|
(143KB) zip
|
1/4/13 |
E-50-06 |
Piping Support Above Ceiling |
(200KB) jpg
|
(146KB) zip
|
1/4/13 |
E-50-07 |
Piping Support at Roof |
(167KB) jpg
|
(140KB) zip
|
1/4/13 |
E-50-08 |
Surface Metal Raceway Assembly Detail |
(276KB) jpg
|
(197KB) zip
|
1/4/13 |
E-50-09 |
Surface Metal Raceway Wiring Detail |
(299KB) jpg
|
(198KB) zip
|
1/4/13 |
E-50-10 |
Receptacle Installation Detail |
(154KB) jpg
|
(157KB) zip
|
1/4/13 |
E-50-11 |
Recessed Cast Box Installation Detail |
(168KB) jpg
|
(141KB) zip
|
1/4/13 |
E-50-12 |
Electrical Wiring Configuration - System Furniture |
(274KB) jpg
|
(188KB) zip
|
2/4/13 |
|
Power Quality & Grounding |
|
|
|
E-60-01 |
Dry Type Transformer 600V or Less Grounding |
(153KB) jpg
|
(146KB) zip
|
1/4/13 |
E-60-02 |
Building Grounding Electrode System |
(257KB) jpg
|
(152KB) zip
|
1/4/13 |
E-60-03 |
Building Electrical System Ground Bus |
(211KB) jpg
|
(154KB) zip
|
1/4/13 |
E-60-04 |
Building Telecommunication System Ground Bus |
(194KB) jpg
|
(148KB) zip
|
1/4/13 |
E-60-05 |
Isolated Ground Receptacle Wiring Diagram |
(185KB) jpg
|
(179KB) zip
|
1/4/13 |
|
Lighting |
|
|
|
E-70-01 |
Pole Base Detail |
(233KB) jpg
|
(221KB) zip
|
6/27/12 |
E-70-02 |
Extended Pole Base Detail |
(240KB) jpg
|
(222KB) zip
|
6/27/12 |
E-70-03 |
BSL3 Lab Lighting Installation |
(176KB) jpg
|
(228KB) zip
|
6/27/12 |
E-70-04 |
Typical Lighting Fixture Installation Detail |
(194KB) jpg
|
(264KB) zip
|
6/27/12 |
|
Miscellaneous |
|
|
|
E-80-01 |
Flat Surface Air Terminal Mounting |
(170KB) jpg
|
(229KB) zip
|
6/27/12 |
E-80-02 |
Adjustable Point-Base & Air Terminal |
(158KB) jpg
|
(226KB) zip
|
6/27/12 |
E-80-03 |
Exhaust Discharge Stack Lighting Protection |
(170KB) jpg
|
(223KB) zip
|
6/27/12 |
E-80-04 |
Down Lead to Ground Connection |
(185KB) jpg
|
(270KB) zip
|
6/27/12 |
E-80-05 |
Ground Rod Structural Steel Connection |
(139KB) jpg
|
(225KB) zip
|
6/27/12 |
E-80-06 |
Lightning Conductor Down Lead Penetration |
(188KB) jpg
|
(233KB) zip
|
6/27/12 |
E-80-07 |
Typical Lab Bench Elevation |
(154KB) jpg
|
(145KB) zip
|
1/4/13 |
to top |
|
|
|
|
General ID |
Title |
JPEG |
CAD |
DATE POSTED |
G-SR01-SB |
Signature Review Stamp Block |
|
(159KB) zip
|
11/23/11 |
G-TB01-8.5X11 |
Division of Techinical Resources Title Block 8.5X11 |
|
(313KB) zip
|
11/23/11 |
G-TB01-11X17 |
Division of Techinical Resources Title Block 11X17 |
|
(415KB Zip)
|
11/23/11 |
G-TB01-24X36 |
Division of Techinical Resources Title Block 24X36 |
|
(151KB) zip
|
11/23/11 |
G-TB01-30X42 |
Division of Techinical Resources Title Block 30X42 |
|
(138KB) zip
|
11/23/11 |
to top |
|
|
|
|
Mechanical ID |
Title |
JPEG |
CAD |
DATE POSTED |
|
Air Side |
|
|
|
M-A2-1 |
Duct Penetration through Masonry or Concrete |
(216KB) jpg
|
(292KB) zip
|
1/4/13 |
M-A2-2 |
Duct Penetration through Stud Wall |
(201KB) jpg
|
(432KB) zip
|
1/4/13 |
M-A4-1 |
Air Terminal (Shut-Off) Unit Installation |
(242KB) jpg
|
(123KB) zip
|
11/22/11 |
M-A7-2 |
Conical Duct Fitting |
(140KB) jpg
|
(183KB) zip
|
12/21/12 |
M-A8-1 |
Exhaust Air Terminal Unit Detail |
(149KB) jpg
|
(136KB) zip
|
1/4/13 |
M-A9-1 |
Freeze Protection Thermostat Installation |
(269KB) jpg
|
(333KB) zip
|
11/22/11 |
|
Control |
|
|
|
M-C1-1 |
Fan Coil Unit Control Diagram |
(210KB) jpg
|
(186KB) zip
|
1/4/13 |
|
Equipment |
|
|
|
M-E4-1 |
End Suction Pump |
(241KB) jpg
|
(406KB) zip
|
12/21/12 |
M-E4-2 |
Horizontal Split Case Pump |
(263KB) jpg
|
(319KB) zip
|
12/21/12 |
M-E4-3 |
In Line Pump Piping Installation |
(162KB) jpg
|
(115KB) zip
|
11/22/11 |
M-E4-4 |
In Line Pump with Redundancy Piping Installation |
(171KB) jpg
|
(116KB) zip
|
11/22/11 |
M-E8-1 |
Exhaust Fan Stack Detail |
(247KB) jpg
|
(165KB) zip
|
12/21/12 |
M-E10-1 |
Exposed Cabinet Type Fancoil Unit Piping Detail |
(246KB) jpg
|
(187KB) zip
|
1/4/13 |
M-E11-1 |
Electric Condensate Return Unit |
(252KB) jpg
|
(177KB) zip
|
12/21/12 |
|
Steam |
|
|
|
M-S1-1 |
End of Run Steam Drip Trap Assembly |
(186KB) jpg
|
(117KB) zip
|
11/22/11 |
M-S1-2 |
Drip at end of steam supply |
(173KB) jpg
|
(116KB) zip
|
11/22/11 |
M-S2-1 |
HP Vertical - Flash Tank Piping |
(194KB) jpg
|
(120KB) zip
|
11/22/11 |
M-S2-2 |
Low Pressure Horizontal-Flash Tank Piping |
(174KB) jpg
|
(160KB) zip
|
12/21/12 |
M-S2-3 |
MP Vertical - Flash Tank Piping |
(194KB) jpg
|
(120KB) zip
|
11/22/11 |
M-S2-4 |
Vertical Flash Tank With Steam Recovery |
(241KB) jpg
|
(194KB) zip
|
1/4/13 |
M-S9-1 |
LP Duct Mounted Steam Humidifier Piping |
(209KB) jpg
|
(119KB) zip
|
11/22/11 |
M-S10-1 |
Steam Condensate Lift to Overhead Return |
(165KB) jpg
|
(180KB) zip
|
1/4/13 |
|
Water Side |
|
|
|
M-W2-1 |
Multiple Chilled Water Coil - Piping detail |
(219KB) jpg
|
(123KB) zip
|
11/22/11 |
M-W3-1 |
HW Reheat Coil Piping (2-way valve) |
(157KB) jpg
|
(133KB) zip
|
11/22/11 |
M-W3-2 |
HW Reheat Coil Piping (3-way valve) |
(163KB) jpg
|
(144KB) zip
|
11/22/11 |
M-W3-3 |
Preheat Glycol Solution HW Coil Piping Detail |
(244KB) jpg
|
(175KB) zip
|
12/21/12 |
M-W4-1 |
Bladder Type Expansion Tank - Vertical |
(145KB) jpg
|
(147KB) zip
|
11/22/11 |
M-W5-1 |
Cooling Coil Drain |
(234KB) jpg
|
(123KB) zip
|
11/22/11 |
M-W5-2 |
Pipe Drain Installation |
(200KB) jpg
|
(201KB) zip
|
11/22/11 |
M-W5-3 |
Safety Relief Valve Detail |
(170KB) jpg
|
(161KB) zip
|
11/22/11 |
M-W5-4 |
Water tight sleeve detail |
(258KB) jpg
|
(204KB) zip
|
12/21/12 |
M-W5-5 |
Air Vent Detail |
(173KB) jpg
|
(155KB) zip
|
11/22/11 |
M-W5-6 |
Cored Slab Pipe Support |
(221KB) jpg
|
(197KB) zip
|
12/21/12 |
M-W5-7 |
Core Drilled Pipe Sleeve Detail |
(170KB) jpg
|
(181KB) zip
|
12/21/12 |
M-W5-8 |
Water Softener Piping |
(200KB) jpg
|
(176KB) zip
|
12/21/12 |
M-W5-9 |
Glycol Make-Up System |
(206KB) jpg
|
(189KB) zip
|
12/21/12 |
M-W5-10 |
Typical Pipe Hunger detail |
(250KB) jpg
|
(225KB) zip
|
12/21/12 |
M-W5-11 |
Pipe Saddle Support Detail |
(235KB) jpg
|
(201KB) zip
|
1/4/13 |
M-W5-12 |
Pipe Support |
(203KB) jpg
|
(188KB) zip
|
1/4/13 |
M-W5-13 |
Temperature Instrument Port |
(193KB) jpg
|
(187KB) zip
|
1/4/13 |
M-W6-1 |
Chilled Water Flat Plate Heat Exchanger |
(272KB) jpg
|
(183KB) zip
|
12/21/12 |
to top |
|
|
|
|
Plumbing ID |
Title |
JPEG |
CAD |
DATE POSTED |
|
Gases |
|
|
|
P-G1-2 |
Utility Ledge Detail |
(143KB) jpg
|
(190KB) zip
|
1/4/13 |
P-G1-3 |
Fume Hood Piping Diagram |
(211KB) jpg
|
(195KB) zip
|
1/4/13 |
|
Sanitary & Vent |
|
|
|
P-S1-1 |
Sanitary Vent thru Roof Detail |
(172KB) jpg
|
(160KB) zip
|
11/22/11 |
P-S1-2 |
HUB Drain with back water valve |
(147KB) jpg
|
(255KB) zip
|
12/21/12 |
P-S1-3 |
Indirect Waste (Sanitary) |
(171KB) jpg
|
(209KB) zip
|
12/21/12 |
|
Water |
|
|
|
P-W1-1 |
Reduced Pressure Backflow Preventer Detail |
(221KB) jpg
|
(185KB) zip
|
11/22/11 |
P-W2-1 |
Emergency Shower Detail |
(186KB) jpg
|
(153KB) zip
|
11/22/11 |
to top |
|
|
|
|