Department of Labor Seal photos representing the workforce - digital imagery© copyright 2001 photodisc, inc.
Department of Labor Seal www.osha.gov   [skip navigational links] Search    Advanced Search | A-Z Index

Infrastructure Repair and Restoration
Community Floodwater Removal and Levee Repair
List of Activity Sheets
    Photo courtesy of FEMA.  This picture shows actual disaster site work conditions and may not illustrate proper safety and health procedures.
Activity Description
  • This activity sheet outlines hazards that apply to inspectors, engineers/hydrologists, mechanics, and construction response and recovery workers involved in floodwater removal in communities and repairing levees.
  • For some operations or situations (e.g., entry into confined spaces, heavy equipment use) other activity sheets also apply; see related activity sheets below.
  • Flooding caused by Hurricane Katrina (2005) resulted in damage to levees and widespread flooding in communities. Rapid removal of floodwaters from neighborhoods and streets was critical. This task would be an initial activity after any disaster that affected the integrity of levees and/or resulted in community flooding.
  • Tasks include inspecting and repairing levees and stationary pumping systems, as well as using portable pumping systems and generators. Response and recovery workers might access the levees and pumps by vessel, vehicle, helicopter, or on foot. Levee repair can involve operations similar to maritime and bridge repair activities.
  • Response and recovery workers conducting this operation may be employed by Federal, State, local, and private employers. Review How to Use This Matrix in the introduction for a discussion of how this information may apply to different employees.

Back to Top Back to Top


About the Activity Sheet

This activity sheet does not provide an in-depth analysis of OSHA standards and regulations and cannot address all hazards. It does not increase or diminish any OSHA requirement or employer obligation under those requirements. It is intended as a guide and quick reference for employers and response and recovery workers. The Matrix captures major activities involved in hurricane response and recovery, highlights many of the hazards associated with them, and recommends beneficial work practices, personal protective equipment (PPE), and other exposure control methods. Employers must evaluate the specific hazards associated with the job/operation at the site where the work is being performed.

Employers are responsible for providing a safe and healthful workplace for their employees. OSHA's role is to assure the safety and health of America's workers by setting and enforcing standards; providing training, outreach, and education; establishing partnerships; and encouraging continual improvement in workplace safety and health.

The Hazard Exposure and Risk Assessment Matrix for Hurricane Response and Recovery Work provides a general overview of particular topics related to current OSHA standards. It does not alter or determine compliance responsibilities in OSHA standards or the
Occupational Safety and Health Act of 1970, or the equivalent State Plan standards and requirements. Because interpretations and enforcement policy may change over time, you should consult current OSHA/State Plan administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts for additional guidance on OSHA compliance requirements. Employers should modify their procedures as appropriate when additional, relevant information becomes available.

Back to Top Back to Top


General Recommendations

Key Engineering Controls and Work Practices. See general recommendations document.

Personal Protective Equipment. The general PPE is recommended for all response/recovery tasks/operations; only the additional PPE that may be needed for a specific hazard is noted below.

General PPE includes:
  • Hard hat for overhead impact or electrical hazards
  • Eye protection with side shields
  • Gloves chosen for job hazards expected (e.g., heavy-duty leather work gloves for handling debris with sharp edges and/or chemical protective gloves appropriate for chemicals potentially contacted)
  • ANSI-approved protective footwear
  • Respiratory protection as necessary—N, R, or P95, filtering facepieces may be used for nuisance dusts (e.g., dried mud, dirt and silt) and mold (except mold remediation). Filters with a charcoal layer may be used for odors

Back to Top Back to Top


Recommendations Specific to Hazards Associated with This Activity


WORK ON, OVER, OR NEAR WATER

Key Engineering Controls and Work Practices

Additional Personal Protective Equipment
  • All personnel should wear Coast Guard-approved Type I or II personal floatation devices
  • Watertight boots with steel toe and insole as needed

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



STRUCTURAL INSTABILITY

Key Engineering Controls and Work Practices
  • Limit access/set up controlled access zones until stability and structural integrity is known
  • Conduct pump and levee evaluations from outside or off damaged structures to the extent feasible
  • Ensure that a competent person inspects building and floors before entry to perform work. A competent person is able to recognize existing and predictable hazardous conditions and has the authority to take prompt corrective measures to eliminate the hazardous conditions
  • Install temporary structural support (shoring, bracing) adequate to protect response and recovery workers while pump houses and levees are repaired

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



FALLS FROM HEIGHTS OR THROUGH OPENINGS

Key Engineering Controls and Work Practices
  • Limit access/set up controlled access zones
  • Use fall protection systems: guardrails, safety nets, or fall arrest systems
  • Cover or guard holes and openings as soon as they are created. Covers must support two times the weight (body, equipment, materials) that may be imposed

Additional Personal Protective Equipment
  • Personal fall arrest system including harnesses, lanyards, lifelines, connectors, anchorages, and anchor points (as needed)

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



GENERAL HEAVY EQUIPMENT OPERATION

    Photo courtesy of FEMA.  This picture shows disaster actual site work conditions and may not illustrate proper safety and health procedures.
Key Engineering Controls and Work Practices

Additional Personal Protective Equipment
  • Hearing protection-see Noise hazard
  • When working from an aerial lift, use a body harness that is properly attached (or body belt for tethering or restraint use only) for fall protection

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



WORK ZONE SAFETY

Key Engineering Controls and Work Practices

Additional Personal Protective Equipment
  • ANSI/ISEA 107-2004 compliant high visibility safety apparel and headwear

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



    Photo courtesy of FEMA.  This picture shows disaster actual site work conditions and may not illustrate proper safety and health procedures.
HELICOPTER USE

Key Engineering Controls and Work Practices
  • Ensure that the pilot and ground personnel conduct a daily briefing to discuss the operating plan
  • Do not overload helicopters
  • Ensure that rigging equipment is inspected, rated for the load, and is protected from any sharp edges of the cargo being hauled
  • Limit access/set up controlled access zones near the helicopter drop zone
  • Ensure that communications are maintained between the load drop area and the helicopter
  • Secure or remove loose gear within 100 feet of the place where a load is lifted or deposited
  • Do not wear loose-fitting clothing that may flap and get snagged on the hoist line

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



CONTACT WITH DOWNED LINES AND LIVE ELECTRICAL EQUIPMENT AND OTHER UTILITIES (E.G., GAS, WATER)

Key Engineering Controls and Work Practices
  • Assume that electrical lines are energized until proven otherwise. Lines and other conductors may become reenergized without warning as utilities are evaluated and restored after a disaster
  • Inspect the work area for downed conductors and do not go near, drive over, or otherwise come in contact with them
  • Downed electrical conductors can energize other objects, including fences, water pipes, bushes, trees, and telephone/CATV/fiber optic cables
  • Unless deenergized and visibly grounded, maintain proper distance from overhead electrical power lines (at least 10 feet) and/or provide insulating barriers
  • Do not approach any gas leaks; if a gas leak is detected, secure spark-producing devices (e.g., engines, tools, electronic, and communications equipment) and evacuate the area until the leak is secured
  • Contact utility company to assist in locating, marking, and shutting off/purging utility lines that may pose a hazard or may be impacted; ensure that lines have been purged as needed before beginning work

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



CONFINED SPACES

Key Engineering Controls and Work Practices
  • Confined spaces have limited means of entry or exit, are large enough to bodily enter, and may contain physical (e.g., mechanical, electrical, hydraulic, pneumatic energy; engulfment hazards; inwardly converging surfaces) or atmospheric hazards (e.g., atmospheres that are oxygen-deficient or oxygen-enriched, contain or may contain flammable gas, vapor or mist, airborne combustible dust, toxic substances, or any other atmosphere that is immediately dangerous to life or health). Examples include storage tanks, process vessels, bins, boilers, vaults, ventilation or exhaust ducts, sewers, tunnels, pipelines, and pits more than 4 feet in depth
  • Hurricane-related events might introduce hazards or potential hazards into confined spaces. For example, a space might have a potential to contain a hazardous atmosphere due to the presence of decomposing organic matter, to the use of hazardous chemicals in the space, or to the performance of operations in the space, such as welding, cutting, or burning, that may create a hazardous atmosphere. Additional precautions must be taken to make the space safe for entry
  • Evaluate the need for entry (i.e., placing any body part into the space)
  • If entry is required, see Entry into Confined Spaces activity sheet

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



VESSEL OPERATION

Key Engineering Controls and Work Practices

Additional Personal Protective Equipment
  • Coast Guard-approved Type I or II personal floatation devices

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



GENERATOR USE

Key Engineering Controls and Work Practices
  • Never attach a generator directly to the electrical system of a structure unless a qualified electrician has installed a transfer switch for the generator. If the structure’s electrical system is not isolated, it may energize the utility’s wiring system for great distances and create a risk of electrocution for utility workers and others in the area
  • Always plug electrical equipment directly into the generator using the manufacturer’s supplied cords or grounded (3-pronged) extension cords that are rated for the total anticipated load
  • Do not overload a generator; it can overheat and create a fire hazard
  • Ground and bond generators according to the manufacturer’s recommendations; ensure that any manufacturer-required connections are secure before using the generator
  • Keep the generator dry; protect with a canopy if needed; do not use it in wet or rainy conditions
  • Carbon monoxide (CO) is a poisonous, colorless, and odorless gas that is produced by the incomplete burning of the generator’s fuel. CO is harmful when breathed because it displaces oxygen in the blood and deprives the heart, brain, and other vital organs of oxygen
  • Never use a generator indoors or in enclosed spaces such as garages and basements; opening windows and doors may not prevent CO from building up in those spaces. Do not use a generator outdoors near doors, windows, and vents that could allow CO to enter
  • Ensure that a generator has 3 to 4 feet of clear space on all sides and above it to ensure adequate ventilation and cooling
  • Before refueling, shut down the generator and allow it to cool

Additional Personal Protective Equipment
Back to Top Back to Top Back to Hazards Index Back to Hazards Index



IMPROPER LADDER OR SCAFFOLD USE

Key Engineering Controls and Work Practices
  • Inspect ladders for cracked, broken, or defective parts before use
  • Do not exceed the load rating of ladders or scaffolds—remember that load ratings include people, tools, and equipment
  • Set up ladders and scaffolds on stable surfaces
  • Set extension or straight ladders at a 75 degree angle from the ground (1/4 foot back for every foot of rise) and provide 3 feet above an upper landing surface to ease climbing onto/descending from height
  • Use non-conductive ladders (e.g., fiberglass) and exercise extreme caution when working near power lines
  • Secure ladders that can be displaced by work activities; consider barricades at the base to keep traffic away
  • Have a competent person inspect scaffolds before use
  • Ensure that the scaffold is plumb, and braced and guyed to prevent tipping, swaying, and displacement
  • Ensure that the scaffold is built on base plates and mudsills, or other firm foundations. Footings should be able to support the scaffold without settling or moving. Do not use unstable objects to support scaffolds
  • Fully plank each scaffold on all working levels. For wood planking, use wood graded for the intended load
  • Provide guardrails or fall protection systems on platforms 10 feet or higher

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



ASBESTOS

Key Engineering Controls and Work Practices

Additional Personal Protective Equipment
  • Based on the initial exposure assessment, select a respirator and protective clothing for visual inspection, sampling, and subsequent abatement work

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



DIVING OPERATIONS

Key Engineering Controls and Work Practices
Back to Top Back to Top Back to Hazards Index Back to Hazards Index



EXPOSURE TO CONTAMINATED WATER AND/OR FLOODWATERS

Key Engineering Controls and Work Practices
    Photo courtesy of FEMA.  This picture shows actual disaster site work conditions and may not illustrate proper safety and health procedures.
  • Reduce the exposure to splash or aerosolized liquid hazards by limiting the number of people in the area and having those in the area stay upwind of water discharge areas
  • Ensure that good hygiene, especially hand washing, is practiced before eating, drinking, and smoking. If clean water is not available, use an alternative such as hand sanitizer or sanitizing wipes
  • Ensure that cuts and bruises are protected from contact with contaminated water
  • Clean areas of the body that come in contact with contaminated water with soap and water, hand sanitizer, or sanitizing wipes
  • If diving is required, ensure that divers and their equipment are appropriately decontaminated (fresh water shower/rinse at minimum) upon completion of dive operations—see Diving and Diver-Support Operations activity sheet

Additional Personal Protective Equipment
  • Goggles if routinely working near splashing floodwater
  • N, R, or P95 respirators may be necessary for exposure to contaminated water that may become aerosolized
  • Watertight boots with steel toe and insoles
  • Waterproof gloves for contact with contaminated water

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



NOISE

Key Engineering Controls and Work Practices
    Photo courtesy of FEMA.  This picture shows disaster actual site work conditions and may not illustrate proper safety and health procedures.
  • Place generators, compressors, and other noisy equipment at a distance or behind a barrier when possible

Additional Personal Protective Equipment
  • Hearing protection when working around potential noise sources and when noise levels exceed 90 dBA. A useful “rule of thumb”—if you cannot hold a conversation in a normal speaking voice with a person who is standing at arms length (approximately 3 feet), the noise level may exceed 90 dBA

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



SILICA, NUISANCE DUST, DRIED MUD, OR SILT

Key Engineering Controls and Work Practices
  • Stay upwind of or away from dust-generating activities, and in particular those involving crystalline silica-containing materials like concrete, brick, tile, drywall, mortar, sand, or stone. When inhaled, the fine crystalline silica particles contained in the dust can become lodged deep in the lung, which can lead to silicosis and other respiratory illnesses
  • Use water spray or mist to suppress dust generation, especially during operations that may create a lot of dust, such as cutting or sawing silica-containing materials, jack hammering, impact drilling, using heavy equipment, and demolishing structures
  • Avoid using compressed air for cleaning surfaces
  • Sample employee exposures to silica during dust-generating activities

Additional Personal Protective Equipment
  • At a minimum, use respirators with N, R, or P95 filters for work with crystalline silica-containing materials (e.g., concrete, brick, tile, mortar). The use of N, R, or P100 filters may provide additional protection. Higher levels of respiratory protection may be needed for some operations (e.g., cutting concrete, sandblasting, mixing concrete)
  • N, R, or P95 respirators may be used for nuisance dusts (e.g., dried mud, dirt, or silt) and mold (except mold remediation). Filters with a charcoal layer may be used for odors

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



DISCOVERY OF HUMAN OR ANIMAL REMAINS

Key Engineering Controls and Work Practices
  • If found, contact public health/mortuary personnel for removal

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



POWER AND HAND TOOL USE

Key Engineering Controls and Work Practices
  • Use ground-fault circuit interrupters (GFCIs) or double insulated power tools, or implement an assured equipment grounding program
  • Inspect power tool condition (including any cords) and verify operation of safety features before use
  • Do not use equipment that is defective, such as equipment with inoperable safety switches, missing guards, frayed/cut cords etc.
  • Ground power tools properly
  • Avoid standing in wet areas when using portable power tools

Additional Personal Protective Equipment
  • Hearing protection—see Noise hazard
  • Hand protection for cut- and abrasion-control and vibration dampening
  • Eye protection appropriate to the impact hazard

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



DISCOVERY OF UNKNOWN CHEMICALS

Key Engineering Controls and Work Practices
  • If hazardous chemical containers are found or leaking materials are detected:
    • Do not use spark-producing devices (e.g., engines, tools, electronic, and communications equipment) in the immediate area
    • Take self-protective measures (i.e., move to a safe distance upwind) and contact hazardous material response personnel for evaluation/removal before continuing work in the area

Additional Personal Protective Equipment
  • Evaluate the need to revise protective clothing, respirator, and glove selection

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



CHEMICAL AND MATERIAL STORAGE AND USE

Key Engineering Controls and Work Practices
  • Segregate and store incompatible chemicals separately. For example, store solvents and oxidizers (e.g., peroxides) separately, and acids and caustics separately
  • Secure compressed gas cylinders and ensure that they are stored properly when not in use (regulators off and valve caps on when not in use; separate oxygen and fuel gas by 20 feet or using a non-combustible barrier (5 ft high, fire-resistant rating of at least ½ hour))
  • Store chemicals in containers approved and designed for chemical storage and mark all storage locations
  • Store and handle hazardous materials in areas with natural or forced ventilation; do not store or handle in low-lying areas
  • Isolate, secure and identify storage areas
  • Prohibit smoking near storage areas
  • Keep ignition sources at least 25 feet away from storage areas
  • Ensure that fire extinguishers and extinguishing agents are available in the immediate area
  • Bond and ground containers before dispensing flammable liquids. Reference 29 CFR 1926.152(e)(2)

Additional Personal Protective Equipment
  • Gloves made of material that will protect user from chemicals handled
  • Face shield or goggles with indirect venting. If a face shield is selected, eye protection must be worn under the face shield
  • Coveralls or apron resistant to chemicals being handled
  • Disposable boot covers resistant to the chemicals being handled
  • A respirator and cartridges specific for chemical, as necessary

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



CUTS AND LACERATIONS

Key Engineering Controls and Work Practices
  • Use special care to avoid pinch and crushing injuries when placing or connecting large, heavy, and awkward equipment
  • Operate pumps with machine guards in place over shafts, belts, gears, and other pinch points
  • See general recommendations document

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



WELDING, CUTTING, AND BURNING

Key Engineering Controls and Work Practices
  • Remove flammable and combustible materials from the area
  • Do not perform “hot work” such as welding, cutting, or burning in areas where flammable, combustible, corrosive, or toxic substances are being used, stored, or may otherwise be present
  • Maintain a fire watch during all hot work until material has cooled
  • Ensure fire extinguishers and extinguishing agents are available in the immediate area
  • Provide natural, exhaust, or forced ventilation to control exposure to the metal fumes and other contaminants being generated (e.g., generator exhaust)
  • Ensure that pipes and other vessels are purged of hazardous materials
  • Identify building materials that will be welded, cut, or burned and that may contain lead, such as painted surfaces and pipes. Test materials and provide exposure controls identified in 29 CFR 1926.62 as necessary; see the lead hazard in the general recommendations document

Additional Personal Protective Equipment
  • Gloves and protective clothing for the activity being performed
  • At a minimum, filtered lenses and face-protection as appropriate for the activity being performed
  • Respiratory protection based on anticipated exposure to metal fumes, including lead

Back to Top Back to Top Back to Hazards Index Back to Hazards Index



    Photo courtesy of FEMA.  This picture shows actual disaster site work conditions and may not illustrate proper safety and health procedures.
OTHER POTENTIAL HAZARDS

Select any of the following potential hazards that can be associated with this activity in order to access relevant recommendations in the general recommendations document:
Back to Top Back to Top Back to Hazards Index Back to Hazards Index



Additional Medical Needs
Back to Top Back to Top

Additional Training Needs
Back to Top Back to Top

Related Activity Sheets
Back to Top Back to Top

Other Resources and References Accessibility Assistance: Contact the OSHA Directorate of Science, Technology and Medicine at 202-693-2300 for assistance accessing OSHA PDF materials.
Back to Top Back to Top
 

Accessibility Assistance: Contact the OSHA Directorate of Science, Technology and Medicine at 202-693-2300 for assistance accessing OSHA PDF materials. Please see the Website Assistance for Browsers, Plugins & Players if you experience difficulty viewing any of the files.

 
 


Back to Top Back to Top www.osha.gov www.dol.gov

Contact Us | Freedom of Information Act | Customer Survey
Privacy and Security Statement | Disclaimers
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210