Cruise Ship Inspection Details

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: Oosterdam Cruise line: Holland America Line Inspection Date: 11/05/2005 Score: 97
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
02Medical logs maintained0
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
10Swimming pools / spas maintained, safety equipment0
21Nonfood-contact surfaces designed, constructed, maintained, installed, located0
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits0
25Wiping cloths / chef=s towels clean, stored, used0
26Food-contact surfaces equipment / utensils clean; Safe0
27Equipment / utensils non-food-contact surfaces clean0
28Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency0
29Facilities convenient, accessible, designed, installed3
33Decks / bulkheads / deckheads construction, repair, clean0
37Rooms / equipment vented, humidity, condensation0
41Child Activity Centers facilities, diaper changing, operation0
999Miscellaneous0
Selected Item Details
Item No.: 08
Site: Potable Water-ELECTRONIC CROSS-CONNECTION CONTROL PROGRAM
Violation: THERE WAS NO SCHEDULE SET FOR THE INSPECTION OF THE VARIOUS NON-TESTABLE TYPE BACKFLOW PREVENTION DEVICES USED THROUGHOUT THE SHIP. ADDITIONALLY, THE ELECTRONIC LIST OF DEVICES USED DID NOT INCLUDE AIR-GAP BACKFLOW PREVENTION IN SOME TECHNICAL AREAS OF THE SHIP. THIS IS A 2005 VSP OPERATIONS MANUAL REQUIREMENT. ACTUAL INSPECTIONS WERE DOCUMENTED WITH DATES IN THE COMPUTER.
Recommendation:5.7.1.1.4 A cross-connection control program shall include at a minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so there is a match to the plumbing system component and location, the program shall set a schedule for inspection frequency. Repeat devices such as toilets can be grouped under a single device type, and air-gaps shall be included in the listing. A log documenting the inspection or maintenance in written or electronic form shall be maintained and be available for review during inspections.
Site: Potable Water-POTABLE WATER TANK DISINFECTION
Violation: THE RECENT ELECTRONIC RECORD OF THE #1 PORT SIDE POTABLE WATER TANK CLEANING AND DISINFECTION ON 30 AUGUST 2005 WAS MISSING THE FINAL FLUSHING STEP FOLLOWING DISINFECTION AND PRIOR TO REFILLING. THIS IS A NEW REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL.
Recommendation:5.3.4.1.3 Documentation of the inspection, maintenance, cleaning, disinfection (to include concentration and contact time of disinfectant), and flushing shall be mainteained for 12 months and shall be available to the VSP for review during inspections.
*Inspections scores of 85 or lower are NOT satisfactory