This report represents the final recommendations of the ADAAG Review Advisory Committee to the US Access Board for revisions to the Americans with Disabilities Act Accessibility Guidelines (ADAAG). This final report is presented in the form of a new set of guidelines.
NOTE: This report is a set of recommendations from the Advisory Committee to the US Access Board. Any proposed revisions to ADAAG will be made through the federal rulemaking process. This report is not part of any rulemaking.
In addition to the scoping and technical provisions presented in this report, the Advisory Committee also recommends a new format for the next edition of ADAAG. Recommendations regarding dimensions, defined terms, language style, and numbering are already incorporated in the report; they are specified here for use by the Access Board. This report does not incorporate the Committee recommendations for layout; figures and commentary were not fully addressed by the Committee. Recommendations for layout, figures and commentary are for use by the Access Board in developing the next final ADAAG.
These guidelines provide scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities. These requirements are to be applied during the design, construction, and alteration of sites, facilities, buildings, and elements to the extent required by regulations issued by Federal agencies under the Americans with Disabilities Act of 1990.
The technical requirements in these guidelines are based upon adult dimensions and anthropometrics.
Nothing in these guidelines is intended to prevent the use of designs or technologies as alternatives to those prescribed in this document, provided they provide equivalent or superior accessibility and usability.
Dimensions that are not stated as "maximum" or "minimum" are absolute. All dimensions are subject to conventional industry tolerances.
105.1 General. The standards referenced in these guidelines and listed in 105.2 shall be considered part of the requirements of these guidelines to the prescribed extent of each such reference. References to standards within the technical and scoping requirements shall apply to the specific edition of the reference standard listed in 105.2. Where differences occur between provisions of these guidelines and referenced standards, the provisions of these guidelines shall apply.
105.2 Referenced Standards.
105.2.1 Power Operated Pedestrian Doors. ANSI/BHMA A156.10-1996.
105.2.2 Power-Assist and Low-Energy Power Operated Doors. ANSI/BHMA A156.19-1996.
105.2.3 Safety Code for Elevators and Escalators. ASME/ANSI A17.1-1993, (including Addenda ASME/ANSI A17.1a-1994 and ASME/ANSI A17.1b-1995)
106.1 General. Terms defined in 106.5 shall have the specified meaning for purposes of this document, unless otherwise stated.
106.2 Terms Defined in Referenced Standards. Terms not defined in this section, but specifically defined in a referenced standard, shall have the specified meaning from the referenced standard, unless otherwise stated.
106.3 Undefined Terms. The meaning of terms not specifically defined in this document or in referenced standards shall be as defined by collegiate dictionaries in the sense that the context implies.
106.4 Interchangeability. Words, terms and phrases used in the singular includes the plural and the plural the singular.
106.5 Defined Terms
Accessible. A site, building, facility, or portion thereof that complies with these guidelines.
Accessible Means of Egress. Means of egress is a continuous and unobstructed way of exit travel from any point in a building or facility to a public way. An accessible means of egress is one that provides an accessible route to an area of refuge, a horizontal exit or a public way.
Accessible Route. A continuous unobstructed path that complies with these guidelines.
Addition. An expansion, extension, or increase in the gross floor area of a building or facility.
Administrative Authority. A governmental agency that adopts or enforces regulations and guidelines for the design, construction, or alteration of buildings and facilities.
Alteration. A change to a building or facility that affects or could affect the usability of the building or facility or part thereof. Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height partitions. Normal maintenance, reroofing, painting or wallpapering, or changes to mechanical and electrical systems are not alterations unless they affect the usability of the building or facility.
Area of Refuge. An area where people who are unable to use stairs may remain temporarily to await further instructions or assistance during emergency evacuation.
Assembly Area. A room or space accommodating a group of individuals for recreational, educational, political, social, or amusement purposes, or for the consumption of food and drink.
Automatic Door. A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal (see power-assisted door).
Building. Any structure used or intended for supporting or sheltering any use or occupancy.
Characters: Letters, numbers, punctuation marks and typographic symbols.
Circulation Path. An exterior or interior way of passage from one place to another for pedestrians, including, but not limited to, walks, hallways, courtyards, stairways, and stair landings.
Closed Circuit Telephone. A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entrance to a facility.
Common Use. Interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people such as the occupants of a homeless shelter, the occupants of an office building, or the guests of such occupants.
Controls and Operating Mechanisms. A component of an element by which the user activates, deactivates, or adjusts the element.
Cross Slope. The slope that is perpendicular to the direction of travel (see running slope).
Curb Ramp. A short ramp cutting through a curb or built up to it.
Destination-oriented Elevator. An elevator system that provides lobby controls to select floor stops, lobby indicators designating which elevator to use and a car indicator designating the floors at which the car will stop.
Detectable Warning. A standardized surface feature built in or applied to walking surfaces or other elements to warn visually impaired people of hazards on a circulation path.
Dwelling Unit. A single unit which provides a kitchen or food preparation area, in addition to rooms and spaces for living, bathing and sleeping. Dwelling units include a single family home or a townhouse used as a transient group home; an apartment building used as a shelter; guest rooms in a hotel that provide sleeping accommodations and food preparation areas; and other similar facilities used on a transient basis. For purposes of these guidelines, use of the term dwelling unit does not imply the unit is used as a residence.
Element. An architectural or mechanical component of a building, facility, space, or site.
Entrance. Any access point to a building or portion of a building or facility used for the purpose of entering. An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware of the entry door or gate.
Facility. All or any portion of buildings, structures, site improvements, complexes, equipment, roads, walks, passageways, parking lots, or other real or personal property located on a site.
Ground Floor. Any occupiable floor less than one story above or below grade with direct access to grade. A building or facility always has at least one ground floor and may have more than one ground floor such as where a split level entrance has been provided or where a building is built into a hillside.
Mezzanine. That portion of a story which is an intermediate floor level placed within the story and having occupiable space above and below its floor.
Marked Crossing. A crosswalk or other identified path intended for pedestrian use in crossing a vehicular way.
Occupiable. A room or enclosed space designed for human occupancy.
Pictogram: A pictorial symbol which is recognized as representing activities, facilities, or concepts.
Power-assisted Door. A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied to the door itself. (See automatic door.)
Public Entrance. An entrance that is not a service entrance.
Public Use. Interior or exterior rooms or spaces that are made available to the general public. Public use may be provided at a building or facility that is privately or publicly owned.
Qualified Historic Building or Facility. A building or facility that is listed in or eligible for listing in the National Register of Historic Places; or designated as historic under an appropriate State or local law.
Ramp. A walking surface which has a running slope steeper than 1:20.
Running Slope. The slope that is parallel to the direction of travel (see cross slope).
Self-Service Storage Facility. Real property designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on a self-service basis.
Service Entrance. An entrance intended primarily for delivery of goods or services.
Sign. An architectural element composed of displayed text, symbolic, tactile or pictorial information.
Site. A parcel of land bounded by a property line or a designated portion of a public right-of- way.
Sleeping Accommodations. Rooms in which people sleep, such as dormitory and hotel or motel guest rooms or suites.
Space. A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
Story. That portion of a building included between the upper surface of a floor and upper surface of the floor or roof next above. A story containing one or more mezzanines has more than one floor level.
Structural Frame. The columns and the girders, beams, trusses and spandrels having direct connections to the columns and all other members which are essential to the stability of the building as a whole.
Tactile. An object that can be perceived using the sense of touch.
Technically Infeasible. With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member which is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces, or features which are in full and strict compliance with the minimum requirements for new construction and which are necessary to provide accessibility.
TTY. Machinery or equipment that employs interactive graphic (typed) communications through the transmission of coded signals across the standard telephone network. The term TTY also refers to devices known as text telephones and TDD's.
Transient Lodging. A building, facility, or portion thereof, excluding inpatient medical care facilities and long term care facilities, that contains one or more dwelling units or sleeping accommodations. Examples of transient lodging include resorts, group homes, hotels, motels, dormitories, homeless shelters, halfway houses and social service lodging.
Vehicular Way. A route intended for vehicular traffic, such as a street, driveway, or parking lot.
Walk. An exterior pathway with a prepared surface intended for pedestrian use, including general pedestrian areas such as plazas and courts.
Wheelchair Space. Space for a single wheelchair and its occupant.
Wheelchair Space Cluster. Locations of two or more adjacent wheelchair spaces along with companion seating in assembly areas.
201.2 Application Based on Building Use. Where a site, building, or facility contains more than one use, each portion shall comply with the applicable requirements for that use.
201.3 Temporary Structures. These guidelines cover temporary buildings and facilities as well as permanent facilities.
202 Application to Existing Buildings and Facilities
202.1 General. Additions and alterations to existing buildings or facilities, including qualified historic buildings and facilities, shall comply with these guidelines except as modified by 202.
202.2 Additions. Each addition to an existing building or facility shall comply with the requirements for new construction. Each addition that affects or could affect the usability of an area containing a primary function shall comply with 202.4.
202.3.1 Prohibited Reduction in Access. An alteration that decreases or has the effect of decreasing the accessibility of a building or facility below the requirements for new construction at the time of alteration is prohibited.
202.3.2 Extent of Application. An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for greater accessibility than that which would be required for new construction.
202.5.1 Procedures for Alterations to Qualified Historic Buildings and Facilities Subject to Section 106 of the National Historic Preservation Act. Where alterations are undertaken to a qualified historic building or facility that is subject to Section 106 of the National Historic Preservation Act, the Federal agency with jurisdiction over the undertaking shall follow the Section 106 process. Where the State Historic Preservation Officer or Advisory Council on Historic Preservation determines that compliance with the requirements for accessible routes, ramps, entrances, or toilet facilities would threaten or destroy the historic significance of the building or facility, the alternative requirements for that element shall apply.
202.5.2 Alterations to Qualified Historic Buildings and Facilities Not Subject to Section 106 of the National Historic Preservation Act. Where alterations are undertaken to a qualified historic building or facility that is not subject to section 106 of the National Historic Preservation Act, and the entity undertaking the alterations believes that compliance with the requirements for accessible routes, ramps, entrances, or toilet facilities would threaten or destroy the historic significance of the building or facility, the entity shall consult with the State Historic Preservation Officer. Where the State Historic Preservation Officer determines that compliance with the accessibility requirements for accessible routes, ramps, entrances or toilet facilities would threaten or destroy the historical significance of the building or facility, the alternative requirements for that element shall apply.
202.5.2.1 Consultation With Interested Persons. Interested persons shall be invited to participate in the consultation process, including State or local accessibility officials, individuals with disabilities, and organizations representing individuals with disabilities.
202.5.2.2 Certified Local Government Historic Preservation Programs. Where the State Historic Preservation Officer has delegated the consultation responsibility for purposes of this section to a local government historic preservation program that has been certified in accordance with section 101(c) of the National Historic Preservation Act of 1966 (16 U.S.C. 470a (c)) and implementing regulations (36 CFR 61.5), the responsibility shall be permitted to be carried out by the appropriate local government body or official.
203.1 General. Sites, buildings, facilities and elements shall be exempt from these guidelines to the extent specified by 203.
203.2 Construction Sites. Structures, sites and equipment directly associated with the actual processes of construction, including, but not limited to scaffolding, bridging, materials hoists, materials storage, or construction trailers are not required to be accessible. Portable toilet units provided for use exclusively by construction personnel on a construction site are not required to be accessible.
203.3 Employee Work Stations. Individual employee work stations are not required to be accessible but shall be located on an accessible route.
203.4 Raised Areas. Raised areas used primarily for purposes of security, life safety, or fire safety, including but not limited to observation galleries, prison guard towers, fire towers, or life guard stands are not required to be accessible or to be served by an accessible route.
203.5 Limited Access Spaces. Spaces accessed only by ladders, catwalks, crawl spaces, very narrow passageways, or tunnels are not required to be accessible.
203.6 Equipment Spaces. Spaces frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment are not required to be accessible. Such spaces include but are not limited to elevator pits, elevator penthouses, mechanical, electrical, or communications equipment rooms, piping or equipment catwalks, water or sewage treatment pump rooms and stations, electric substations and transformer vaults, and highway and tunnel utility facilities.
203.7 Single Occupant Structures. Single occupant structures accessed only by passageways below grade or elevated above grade, including but not limited to toll booths that are accessed only by underground tunnels, are not required to be accessible.
204.1 General. Protruding objects on circulation paths shall comply with 307.
205 Controls and Operating Mechanisms
205.1 General. Controls and operating mechanisms on accessible routes and in accessible rooms and spaces shall comply with 309.
206.1 General. Accessible routes shall be provided in accordance with 206.
206.2 Where Required. Accessible routes shall be provided where required by 206.2.1 through 206.2.7 and shall comply with Chapter 4.
206.2.3.1 Stairs and Escalators in Existing Buildings. In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for such installation, an accessible route shall be provided between the levels served by the escalator or stair, unless exempted by 206.2.3.
206.2.6 Performance Areas. An accessible route shall be provided where a circulation path directly connects a performance area to an assembly seating area. An accessible route shall be provided from performance areas to ancillary areas or facilities used by performers. In alterations, where it is technically infeasible to alter all performance areas to be on an accessible route, at least one of each type of performance area shall be made accessible.
206.2.7 Raised Platforms. In banquet rooms or spaces where a head table or speaker's lectern is located on a raised platform, an accessible route shall be provided to the platform. Open edges of the raised platform shall be obstructed by placement of tables or provided with edge protection complying with 405.9.
206.3 Location. Accessible routes shall coincide with or be located in the same area as a general circulation path. Where the circulation path is interior, the accessible route shall also be interior.
206.4.1 Parking Garage Entrances. Where direct access to a building is provided for pedestrians from an enclosed parking garage, at least one direct entrance from the garage to the building shall be accessible.
206.4.2 Entrances from Tunnels or Elevated Walkways. Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building, at least one direct entrance to the building from each tunnel or walkway shall be accessible.
206.4.3 Public Entrances. In addition to accessible entrances required by 206.4.1 and 206.4.2, at least 50 percent of all other public entrances shall be accessible. At least one accessible entrance shall be a ground floor entrance.
206.4.4 Tenant Spaces. At least one accessible entrance shall be provided to each tenancy in a facility.
206.4.5 Service Entrances. If a service entrance is the only entrance to a building or to a tenancy in a facility, that entrance shall be accessible.
206.4.6 Signs. Where not all entrances are accessible, accessible entrances shall be identified by the International Symbol of Accessibility complying with 703.7 and directional signs indicating the location of the nearest accessible entrance shall be provided at inaccessible entrances. Directional signs shall comply with 703.4. No signs are required where all entrances are accessible.
206.5 Doors and Doorways. Accessible doors and doorways shall be provided in accordance with 206.5.1 and 206.5.2 and shall comply with 404.
206.5.1 Accessible Entrances. Each accessible entrance to a building or facility shall have at least one accessible door or doorway.
206.5.2 Accessible Rooms and Spaces. Within a building or facility, at least one door or doorway serving each accessible room or space shall be accessible.
206.6.1 Existing Elevators. Altered elements of existing elevators shall comply with 407.5. Such elements shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator and shall comply with the requirements of 407.5.
206.7 Wheelchair (Platform) Lifts. Wheelchair (platform) lifts shall be permitted as a component of an accessible route in new construction as permitted by 206.7.1 through 206.7.3, and shall comply with 408. Wheelchair (platform) lifts provided as a component of an accessible route in an existing building shall comply with 408.
206.7.1 Performance Areas. Wheelchair (platform) lifts shall be permitted to provide an accessible route to a performance area in an assembly occupancy.
206.7.2 Wheelchair Spaces. Wheelchair (platform) lifts shall be permitted to comply with the wheelchair space dispersion and line-of-sight requirements of 221 and 802.
206.7.3 Incidental Spaces. Wheelchair (platform) lifts shall be permitted to provide an accessible route to incidental occupiable spaces and rooms which are not open to the general public and which are occupied by five persons maximum, including but not limited to equipment control rooms and projection booths.
207 Accessible Means of Egress
207.2 Elevators. In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying with 409.3.
207.3 Signs. At exit stairways and elevators serving a required accessible space, but not serving as an accessible means of egress, directional signs indicating the location of accessible means of egress shall be provided. Such signs shall comply with 703.4.
208.1 General. Where parking spaces are provided, accessible parking spaces shall be provided in accordance with 208.
208.2 Number Required. Accessible parking spaces shall be provided in accordance with Table 208.2, except as required by 208.2.1, and shall comply with 502.
Total Number of Parking Spaces | Minimum Required Number of Accessible Spaces |
---|---|
1 to 25 | 1 |
26 to 50 | 2 |
51 to 75 | 3 |
76 to 100 | 4 |
101 to 150 | 5 |
151 to 200 | 6 |
201 to 300 | 7 |
301 to 400 | 8 |
401 to 500 | 9 |
501 to 1000 | 2 percent of total |
1001 and over | 20, plus 1 for each 100 over 1000 |
208.2.1 Rehabilitation Facilities and Outpatient Physical Therapy Facilities. Twenty percent of patient and visitor parking spaces provided at rehabilitation facilities and outpatient physical therapy facilities shall be accessible.
208.2.2 Van Parking Spaces. For every eight or fraction of eight accessible parking spaces required by 208.2 and 208.2.1, at least one shall be a van parking space complying with 502.
209.1 General. Where passenger loading zones are provided, they shall comply with 503.
209.2 Medical Facilities. A passenger loading zone shall be provided at an accessible entrance to licensed medical and long-term care facilities where people receive physical or medical treatment or care and where the period of stay exceeds 24 hours.
209.3 Valet Parking: Valet parking services shall provide a passenger loading zone.
210.2 Required Alterations. Where stair alterations are required by building and safety codes to correct unsafe conditions, the alteration shall comply with 504 unless technically infeasible or exempted by 210.1.
211 Drinking Fountains and Water Coolers
211.1 General. Where fixed drinking fountains or water coolers are provided, at least 50%, but not less than one, of such units provided on each floor shall comply with 602.
213 Toilet and Bathing Facilities
213.1 General. Where toilet or bathing facilities are provided, they shall comply with 213. Where toilet or bathing facilities are provided on an inaccessible level, toilet and bathing facilities shall also be provided on an accessible level.
213.2.1 Unisex Toilet and Bathing Rooms. A unisex toilet room shall comply with 603, shall contain one water closet and one lavatory, and the door shall have a privacy latch. A unisex bathing room shall comply with 603 and shall contain at least one shower or bathtub.
213.2.2 Signs. Where existing toilet or bathing rooms are altered and not made accessible, directional signs indicating the location of the nearest accessible toilet or bathing room within the facility shall be provided. Such signs shall comply with 703.4 and shall include the International Symbol of Accessibility complying with 703.7. Where existing toilet or bathing rooms are altered and not made accessible, the accessible toilet or bathing room shall be identified by the International Symbol of Accessibility complying with 703.7.
213.3 Fixtures and Accessories. Plumbing fixtures and accessories provided in toilet or bathing rooms required to be accessible by 213.2 shall comply with 213.3.1 through 213.3.7.
213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one shall be a wheelchair accessible compartment complying with 604.8.1. Where six or more toilet compartments are provided, an ambulatory accessible compartment complying with 604.8.2 shall be provided in addition to the compartment complying with 604.8.1. Water closets in such compartments shall comply with 604.
213.3.2 Water Closets. Where water closets are provided, but are not in toilet compartments, at least one shall comply with 604.
213.3.3 Urinals. Where urinals are provided, at least one shall comply with 605.
213.3.4 Lavatories. Where lavatories are provided, at least one shall comply with 606. Where only one accessible lavatory is provided, it shall not be located in a toilet compartment.
213.3.5 Mirrors. Where mirrors are provided, at least one shall comply with 603.3.
213.3.6 Controls and Dispensers. Where controls, dispensers, receptacles or other equipment is provided, at least one of each type shall comply with 309.
213.3.7 Bathing Facilities. Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.
214.1 General. Where washing machines or clothes dryers are provided in spaces required to be accessible, at least one of each type shall comply with 611.
216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703.
216.2 Permanent Designations. Where exterior signs are provided as permanent designations of permanent interior rooms and spaces at the door to the space they serve, the signs shall be tactile and shall comply with 703.2. Where interior signs are provided as permanent designations of permanent interior rooms and spaces, the signs shall be tactile and shall comply with 703.2. Where pictograms are provided as permanent designations of permanent interior rooms and spaces, the pictograms shall comply with 703.6 and shall have tactile text descriptors complying with 703.2.
216.4 Exit Doors. Exit doors shall be identified by tactile signs complying with 703.2.
217.1 General. Where public pay telephones, public closed-circuit telephones, or other types of public telephones are provided, accessible public telephones shall be provided in accordance with 217 for each type of public telephone provided. For purposes of this section, a bank of telephones shall be considered two or more adjacent telephones.
217.2 Wheelchair Accessible Telephones. Where public telephones are provided, wheelchair accessible telephones complying with 704.2 shall be provided in accordance with Table 217.2.
No. of Telephones on a Floor or Level | Minimum No. Wheelchair Accessible Telephones |
---|---|
1 or more single unit | 1 per floor or level |
1 bank | 1 per floor or level |
2 or more banks | 1 per bank 1 |
Note.
217.4 TTYs. TTYs complying with 704.4 shall be provided in accordance with 217.4.1 through 217.4.8.
217.4.2 Floor Requirement. Where four or more public pay telephones are provided on a floor of a building, at least one public TTY shall be provided on that floor.
217.4.3 Building Requirement. Where four or more public pay telephones are provided in a building, at least one public TTY shall be provided in the building.
217.4.4 Site Requirement. Where four or more public pay telephones are provided on a site, at least one public TTY shall be provided on the site.
217.4.5 Rest Stops, Emergency Roadstops, and Service Plazas. Where a public pay telephone is provided at a public rest stop, emergency roadstop or service plaza, at least one public TTY shall be provided.
217.4.6 Hospitals. Where a public pay telephone is provided in or adjacent to a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each such location.
217.4.7 Transportation Facilities. Transportation facilities shall be provided with TTYs in accordance with 1003.2.6 and 1004.2 in addition to the TTYs required by 217.4.1 through 217.4.4.
217.4.8 Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7. Directional signs indicating the location of the nearest public TTY shall be provided at all banks of public pay telephones not containing a public TTY. Such signs shall comply with 703.4 and shall include the International Symbol of TTY complying with 703.7.
217.5 Shelves for Portable TTYs. Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical outlet in accordance with 704.5.
218.1 General. Transportation facilities shall comply with Chapter 10.
219 Assistive Listening Systems
219.1 General. Assistive listening systems shall be provided in accordance with 219 and shall comply with 706.
219.2 Required Systems. Assembly areas having fixed seating shall have an assistive listening system where the area is equipped with an audio amplification system or the area has a capacity of 50 or more persons. Other assembly areas shall have an assistive listening system, or an adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive listening system.
219.3 Receivers. Receivers complying with 706.4 shall be provided for assistive listening systems in accordance with Table 219.3. Twenty five percent of receivers, but not less than two, shall be hearing aid compatible in accordance with 706.5.
Fixed Seating in Assembly Area | Minimum Required Number of Receivers |
50 or less | 2 |
51 to 500 | 2, plus 4 for each total seating capacity increase of 100 above 51 |
501 to 1000 | 20, plus 3 for each total seating capacity increase of 100 above 501 |
1001 to 2000 | 35, plus 2 for each total seating capacity increase of 100 above 1001 |
over 2000 | 55, plus 1 for each total seating capacity increase of 100 above 2000 |
219.4 Signs. Where assistive listening systems are provided, signs shall be provided to inform patrons of the availability of the system. The signs shall be located at ticket offices or windows, where ticket offices or windows are provided. The signs shall comply with 703.4 and shall include the International Symbol of Access for Hearing Loss complying with 703.7.
220 Automatic Teller Machines and Fare Machines
220.1 General. Where automatic teller machines or self-service fare vending, collection, or adjustment machines are provided, at least one machine of each type at each location where such machines are provided shall comply with 707. Where bins are provided for envelopes, waste paper, or other purposes, at least one of each type shall comply with 905.
221 Wheelchair Spaces in Assembly Seating
221.1 General. In assembly seating areas, accessible wheelchair spaces shall be provided in accordance with 221.
221.2 Number Required. Accessible wheelchair spaces shall be provided in accordance with Table 221.2 and shall comply with 802.
Assembly Area Seating Capacity | Minimum Required Number of Wheelchair Spaces |
50 or less | 2 |
51 to 100 | 4 |
101 to 300 | 5 |
301 to 500 | 6 |
over 500 | 6, plus 1 additional space for each total seating capacity increase of 200 |
Assembly Area Seating Capacity | Minimum No. of Wheelchair Space Clusters |
up to 300 | 1 |
301 to 600 | 2 |
601 to 900 | 3 |
901 to 1500 | 4 |
1501 to 2100 | 5 |
2101 to 3000 | 6 |
over 3000 | 6 plus 1 additional cluster for each 1000 seats or portion thereof. |
221.4 Dispersion of Wheelchair Space Clusters.
221.4.1 General. Dispersion of wheelchair space clusters shall be based on the availability of accessible routes to various seating areas including seating at various levels in multi-level facilities.
221.4.3 Separation Between Clusters. Wheelchair space clusters shall be separated by a minimum of five intervening rows or by a minimum of ten intervening seats. Wheelchair spaces within any one wheelchair space cluster shall not be separated by an intervening row, nor by more than two intervening seats, nor by more than a 7-inch (180 mm) vertical level change.
222 Dressing, Fitting and Locker Rooms
223 Medical Care Facility Patient or Resident Sleeping Rooms
223.1 General. In licensed medical and long-term care facilities where people receive physical or medical treatment or care and where the period of stay exceeds twenty-four hours, accessible patient or resident sleeping rooms shall be provided in accordance with 223 and shall comply with 804.
223.1.1 Alterations. Where sleeping rooms are altered or added, the requirements of 223 shall apply only to the sleeping rooms being altered or added.
223.2 Hospitals. In general purpose hospitals, psychiatric facilities and detoxification facilities, at least 10 percent, but not less than one, of the patient sleeping rooms shall be accessible.
223.3 Rehabilitation Facilities. In hospitals and rehabilitation facilities that specialize in treating conditions that affect mobility, and in units within hospitals and rehabilitation facilities which specialize in treating conditions that affect mobility, 100 percent of the patient sleeping rooms shall be accessible.
223.4 Long Term Care Facilities. In long term care facilities, at least 50 percent, but not less than one, of the resident sleeping rooms shall be accessible.
224 Transient Lodging Guest Rooms
224.1 General. Transient lodging facilities shall provide guest rooms in accordance with 224.
224.1.1 Alterations. Where guest rooms are altered or added, the requirements of 224 shall apply only to the guest rooms being altered or added.
224.1.2 Guest Room Doors and Doorways. Entrance and passage doors and doorways into and within all guest rooms shall provide clear width complying with 404.2.3.
224.2 Accessible Guest Rooms. In transient lodging facilities, accessible guest rooms shall be provided in accordance with Table 224.2 and shall comply with 805.2.
Total Guest Rooms | Number of Accessible Rooms W/o Roll-in Showers |
Number of Accessible Rooms W/ Roll-in Showers |
Total Required Accessible Rooms |
1 to 25 | 1 | 0 | 1 |
26 to 50 | 2 | 0 | 2 |
51 to 75 | 3 | 1 | 4 |
76 to 100 | 4 | 1 | 5 |
101 to 150 | 5 | 2 | 7 |
151 to 200 | 6 | 2 | 8 |
201 to 300 | 7 | 3 | 10 |
301 to 400 | 8 | 4 | 12 |
401 to 500 | 9 | 4 | 13 |
501 to 1000 | 2% of total | 1% of total | 3% of total |
1001 and over | 20 plus 1 for each 100 over 1000 | 10 plus 1 for each 100 over 1000 | 30 plus 2 for each 100 over 1000 |
224.3 Accessible Beds. In rooms or spaces having four or more beds, the number of beds in the room or space required to have clear floor space complying with 805.2.3 shall comply with Table 224.3
Total Beds in a Guest Room | Minimum Number of Accessible Beds |
4 to 25 | 1 |
26 to 50 | 2 |
51 to 75 | 4 |
76 to 100 | 5 |
101 to 150 | 7 |
151 to 200 | 8 |
201 to 300 | 10 |
301 to 400 | 12 |
401 to 500 | 13 |
501 to 1000 | 3% of total |
1001 and over | 30 plus 2 for each 100 over 1000 |
224.4 Communication Features. In transient lodging facilities, guest rooms with accessible communication features shall be provided in accordance with Table 224.4 and shall comply with 805.3.
Total Guest Rooms Provided | Minimum Guest Rooms with Accessible Communication Features |
1 to 25 | 2 |
26 to 50 | 4 |
51 to 75 | 7 |
76 to 100 | 9 |
101 to 150 | 12 |
151 to 200 | 14 |
201 to 300 | 17 |
301 to 400 | 20 |
401 to 500 | 22 |
501 to 1000 | 5% of total |
1001 and over | 50 plus 3 for each 100 over 1000 |
224.5 Dispersion. Guest rooms required to comply with 805.2 and 805.3 shall be dispersed among the various classes of guest rooms.
225 Self-Service Storage Facilities
225.1 General. Self-service storage facilities shall provide accessible individual self-storage spaces in accordance with Table 225.1.
Total Spaces in Facility | Minimum Number of Required Accessible Spaces |
1 to 200 | 5%, but not less than 1 |
201 and over | 10, plus 2% of total number of units over 200 |
225.2 Dispersion. Accessible individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided. Where more classes of spaces are provided than the number of required accessible spaces, the number of accessible spaces shall not be required to exceed that required by Table 225.1. Accessible spaces shall be permitted to be dispersed in a single building of a multi-building facility.
226 Seating at Tables, Counters and Work Surfaces
226.1 General. Where seating at fixed or built-in tables, counters or work surfaces is provided in accessible spaces, at least five percent, but not less than one, of the seating shall comply with 902.
226.2 Dining Counters. Where food or drink is served for consumption at counters exceeding 34 inches (865 mm) in height, a 60 inch (1525 mm) minimum length portion of the counter shall comply with 902, or service shall be provided at accessible tables in the same area.
226.3 Dispersion. In new construction, and where practicable in alterations, accessible fixed or built-in seating at tables, counters or work surfaces shall be distributed throughout the space or facility containing such elements.
227 Sales and Service Counters
227.1 General. Where sales and service counters are provided, they shall be accessible in accordance with 227.
Total Check-out Aisles of Each Function | Minimum Accessible Check-out Aisles of Each Function |
1-4 | 1 |
5-8 | 2 |
9-15 | 3 |
over 15 | 3, plus 20% of additional aisles |
227.2.1 Identification. Accessible check-out aisles shall be identified by the International Symbol of Accessibility complying with 703.7, unless all check-out aisles in the facility are accessible. The sign shall be above the check-out aisle in the same location as the check-out aisle number or type of check-out identification.
227.4 Food Service Lines. Food service lines shall comply with 904.5. Where self-service shelves are provided, at least 50 percent, but not less than one, of each type provided shall comply with 308.
227.5 Queue and Waiting Lines. Queue and waiting lines servicing accessible counters or check-out aisles shall comply with 403.
228.1 General. Where fixed or built-in storage elements such as cabinets, shelves, medicine cabinets, closets, and drawers are provided in accessible spaces, at least one of each type shall comply with 905.
228.2 Lockers. Where lockers are provided in accessible spaces, at least five percent, but not less than one, of each type shall comply with 905.
228.3 Shelving and Display Units. Self-service shelves and display units in mercantile occupancies and shelving in stack areas of libraries shall be located on an accessible route complying with 402. Such shelving and display units shall not be required to comply with reach range provisions of 308.
228.4 Coat Hooks and Folding Shelves. Where coat hooks or folding shelves are provided in inaccessible toilet rooms, toilet compartments, or in dressing, fitting or locker rooms, at least one of each type shall be provided in accessible toilet rooms, toilet compartments and dressing, fitting and locker rooms.
228.5 Displays in Qualified Historic Buildings and Facilities. In alterations to qualified historic buildings and facilities, where alternative requirements of 202.5 are permitted, displays and written information shall be located where they can be seen by a seated person. Exhibits and sign displayed horizontally shall be 44 inches (1120 mm) maximum above the floor.
229 Vending Machines and Similar Equipment
229.1 General. In restaurants and cafeterias, spaces for vending machines and similar equipment shall comply with 304 , 305 and 308.
301.1 Scope. The provisions of this chapter apply where required by Chapter 2 or by Chapters 4 through 10.
302.1 General. Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302.
302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim along the entire length of the exposed edge. Carpet edge trim shall comply with 303.
302.3 Openings. Openings in floor or ground surfaces shall be of a size that does not permit passage of a 1/2 inch (13 mm) diameter sphere, except as allowed in 407 and 408. Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel.
303.1 General. Where changes in level are permitted in floor or ground surfaces, they shall comply with 303.
303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical.
303.3 Beveled. Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
303.4 Ramps. Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406.
304.1 General. Wheelchair turning space shall comply with 304.
304.2 Floor or Ground Surface. Floor or ground surfaces of a wheelchair turning space shall have a slope not steeper than 1:48 and shall comply with 302. Changes in level are not permitted.
304.3 Size. Wheelchair turning space shall comply with 304.3.1 or 304.3.2.
304.3.1 Circular Space. The wheelchair turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306.
304.3.2 T-shaped Space. The wheelchair turning space shall be a T-shaped space within a 60-inch (1525 mm) minimum square with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum. Such space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm.
304.4 Doors. Unless otherwise specified, doors shall not be prohibited from swinging into a wheelchair turning space.
305 Clear Floor or Ground Space
305.1 General. Clear floor or ground space shall comply with 305.
305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall have a slope not steeper than 1:48 and shall comply with 302. Changes in level are not permitted.
305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum.
305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306.
305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element.
305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin or overlap an accessible route or adjoin another clear floor or ground space.
305.7 Maneuvering Clearance. Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance complying with 305 shall be provided in accordance with 305.7.1 and 305.7.2.
305.7.1 Forward Approach. Where the depth of the alcove or other restriction exceeds 24 inches (610 mm), the width of the clear floor space shall be 36 inches (915 mm) minimum.
305.7.2 Parallel Approach. Where the depth of the alcove or other restriction exceeds 15 inches (380 mm), the length of the clear floor space shall be 60 inches (1525 mm) minimum.
306.1 General. Where space beneath an object is included as part of clear floor or ground space or wheelchair turning space, the space shall comply with 306. Additional space shall not be prohibited beneath an object; however, such additional space shall not be considered as part of the clear floor or ground space or wheelchair turning space.
306.2.1 General. Space under an object between the floor or ground and 9 inches (230 mm) above the floor or ground shall be considered toe clearance and shall comply with 306.2.
306.2.2 Maximum Depth. Toe clearance shall extend 25 inches (635 mm) maximum under an object.
306.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum beneath the element.
306.2.4 Additional Clearance. Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the floor or ground shall not be considered toe clearance.
306.2.5 Width. Toe clearance shall be 30 inches (760 mm) minimum in width.
306.3.1 General. Space under an object between 9 inches (230 mm) and 27 inches (685 mm) above the floor or ground shall be considered knee clearance and shall comply with 306.3.
306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (635 mm) maximum under an object at 9 inches (230 mm) above the floor or ground.
306.3.3 Minimum Required Depth. Where knee clearance is required beneath an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) minimum in depth at 9 inches (230 mm) above the floor or ground, and 8 inches (205 mm) minimum in depth at 27 inches (685 mm) above the floor or ground.
306.3.4 Clearance Reduction. Between 9 inches (230 mm) and 27 inches (685 mm) above the floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) for each 6 inches (150 mm) in height.
306.3.5 Width. Knee clearance shall be 30 inches (760 mm) minimum in width.
307.1 General. Protruding objects shall comply with 307.
307.4 Reduced Vertical Clearance. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the floor or ground.
307.5 Required Clear Width. Protruding objects shall not reduce the clear width required for accessible routes.
308.1 General. Reach ranges shall comply with 308.
308.2.1 Unobstructed. Where a clear floor or ground space allows only a forward approach to an object and is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the floor or ground.
308.2.2 Obstructed High Reach. Where a clear floor or ground space allows only a forward approach to an object and the high forward reach is over an obstruction, the clear floor space shall extend beneath the object for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum for a reach depth of 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum for a reach depth of 25 inches (635 mm) maximum.
308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an object and the depth of any obstruction between the clear floor or ground space and the object is 10 inches (255 mm) maximum, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor or ground.
308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an object and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (1170 mm) maximum for a reach depth of 24 inches (610 mm) maximum.
309 Controls and Operating Mechanisms
309.1 General. Controls and operating mechanisms shall comply with 309.
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided.
309.4 Operation. Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls and operating mechanisms shall be 5 lb (22.2 N) maximum.
401.1 Scope. Accessible routes and accessible means of egress required by Chapter 2 shall comply with the applicable provisions of this chapter.
402.1 General. Accessible routes shall comply with 402.
402.2 Components. Accessible routes shall consist of one or more of the following components: Walking surfaces with a slope not steeper than 1:20, doorways, ramps, elevators and platform (wheelchair) lifts. All components of an accessible route shall comply with the applicable portions of this chapter.
403.1 General. Walking surfaces that are a part of an accessible route shall comply with 403.
403.2 Floor or Ground Surface. Floor or ground surfaces shall comply with 302.
403.3 Slope. The running slope of walking surfaces shall be not steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48.
403.4 Changes in Level. Changes in level shall comply with 303.
403.5.1 Clear Width at Turn. Where the accessible route makes a 180 degree turn around an object which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48 inches (1220 mm) minimum during the turn and 42 inches (1065 mm) leaving the turn.
403.5.2 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum. Passing spaces shall be either a 60 inch (1525 mm) minimum by 60 inch (1525 mm) minimum space, or an intersection of two walking surfaces which provide a T-shaped space complying with 304.
403.5.3 Protruding Objects. Protruding objects shall comply with 307. Protruding objects shall not reduce the required clear width.
404.1 General. Doors and doorways that are part of an accessible route shall comply with 404.
404.2 Manual Doors and Doorways. Manual doors and doorways and manual gates, including ticket gates, shall comply with 404.2.1 through 404.2.11.
404.2.1 Revolving Doors and Turnstiles. Revolving doors and revolving turnstiles shall not be part of an accessible route.
404.2.2 Double-Leaf Doors. At least one of the active leaves of doorways with two independently operated leaves shall comply with 404.2.3 and 404.2.4.
404.2.4 Maneuvering Clearances.
404.2.4.1 Swinging Doors. Approaches to swinging doors shall have maneuvering clearances complying with Table 404.2.4.1.
TYPE OF USE | MINIMUM MANEUVERING CLEARANCE 1 | ||
Approach Direction | Door Side | Perpendicular to Doorway | Parallel to Doorway 2 (beyond latch side unless noted) |
From front | Pull | 60 inches (1525 mm) | 18 inches (455 mm) |
From front | Push | 48 inches (1220 mm) | 0 inches (0 mm) 3 |
From hinge side | Pull | 60 inches (1525 mm) | 36 inches (915 mm) |
From hinge side | Pull | 54 inches (1370 mm) | 42 inches (1065 mm) |
From hinge side | Push | 42 inches (1065 mm) 4 | 22 inches (560 mm) beyond hinge side |
From latch side | Pull | 48 inches (1220 mm) 5 | 24 inches (610 mm) |
From latch side | Push | 42 inches (1065 mm) 5 | 24 inches (610 mm) |
404.2.4.2 Doorways without Doors, Sliding Doors and Folding Doors. Approaches to doorways without doors which are less than 36 inches (915 mm) wide and approaches to sliding and folding doors shall have maneuvering clearances complying with Table 404.2.4.2.
MINIMUM MANEUVERING CLEARANCE1 | ||
Approach Direction | Perpendicular to Doorway | Parallel to Doorway 2 (beyond stop/latch side unless noted) |
From Front | 48 inches (1220 mm) | 0 inches ( 0 mm) |
From side (doorway with no door only) | 42 inches (1065 mm) | 0 inches (0 mm) |
From pocket/hinge side | 42 inches (1065 mm) | 22 inches (560 mm) beyond pocket/hinge side |
From stop/latch side | 42 inches(1065 mm) | 24 inches (610 mm) |
404.2.4.3 Doors in Alcoves. Doors in alcoves where the plane of the doorway is offset more than 8 inches (205 mm) from the plane of the wall shall provide maneuvering clearances for front approach.
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall have a slope of 1:48 maximum and shall comply with 302. Changes in level are not permitted.
404.2.6 Two Doors in Series. The distance between two hinged or pivoted doors in series shall be 48 inches (1220 mm) minimum plus the width of any door swinging into the space. Doors in series shall swing either in the same direction or away from the space between the doors.
404.2.8.1 Door Closers. Door closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to an open position of 12 degrees is 5 seconds minimum.
404.2.8.2 Spring Hinges. Door spring hinges shall be adjusted so that from the open position of 70 degrees, the door shall move to the closed position in 1.5 seconds minimum, measured under ambient conditions.
404.2.9 Door Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority. The required force for pushing or pulling open a door other than fire doors shall be as follows:
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.
404.2.11 Vision Lites. Doors, and sidelites adjacent to doors, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum above the floor.
404.3 Automatic Doors. Automatic doors and automatic gates shall comply with 404.3.1 through 404.3.6. Full-powered automatic doors shall comply with ANSI/BHMA A156.10. Low-energy and power- assisted doors shall comply with ANSI/BHMA A156.19.
404.3.1 Clear Width. Doorways shall have a clear opening of 32 inches (815 mm) minimum in power- on and power-failure mode. The minimum clear width for automatic door systems shall be based on the clear opening provided by all leafs in the open position.
404.3.2 Maneuvering Clearance. Clearances at power-assisted doors shall comply with 404.2.4.
404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5.
404.3.4 Two Doors in Series. Doors in series shall comply with 404.2.6.
404.3.5 Controls and Operating Mechanisms. Control switches shall comply with 309.
404.3.6 Signs. Labels and warnings for automatic doors shall comply with 703.4.
405.1 General. Walking surfaces on accessible routes with a running slope steeper than 1:20 are ramps and shall comply with 405.
Slope 1 | Maximum Rise |
Steeper than 1:10 but not steeper than 1:8 | 3 inches (75 mm) |
Steeper than 1:12 but not steeper than 1:10 | 6 inches (150 mm) |
405.3 Cross Slope. Cross slope of ramp runs shall not be steeper than 1:48.
405.4 Floor or Ground Surfaces. Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs.
405.5 Clear Width. The clear width of a ramp run and the clear width between handrails, if provided, shall be 36 inches (915 mm) minimum.
405.6 Rise. The rise for any ramp run shall be 30 inches (760 mm) maximum.
405.7 Landings. Ramps shall have landings at bottom and top of each ramp run. Landings shall comply with 405.7.1 through 405.7.5.
405.7.1 Slope. Landings shall have a slope not steeper than 1:48 and shall comply with 302. Changes in level are not permitted.
405.7.2 Width. The landing shall be at least as wide as the widest ramp run leading to the landing.
405.7.3 Length. The landing length shall be 60 inches (1525 mm) minimum.
405.7.4 Change in Direction. Ramps that change direction between runs at landings shall have a 60 inch (1525 mm) minimum by 60 inch (1525 mm) minimum landing.
405.7.5 Doorways. Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area.
405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying with 505.
405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505.
405.9.2 Guard, Curb or Barrier. A guard, curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the floor or ground surface.
405.10 Outdoor Conditions. Outdoor ramps and outdoor approaches to ramps shall be designed so that water will not accumulate on walking surfaces.
406.1 General. Curb ramps on accessible routes shall comply with 406 and with 405.2, 405.4 , 405.5 and 405.10.
406.2 Counter Slope. Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20. The adjacent surfaces at transitions at curb ramps to walks, gutters and streets shall be at the same level.
406.3 Sides of Curb Ramps. Curb ramps located where pedestrians must walk across the ramp shall have flared sides. Slope of the flares shall not be steeper than 1:10. Where the width of the walking surface at the top of the ramp and parallel to the run of the ramp is less than 48 inches (1220 mm) wide, the flared sides shall have a slope not steeper than 1:12. Curb ramps with returned curbs shall be permitted where pedestrians would not normally walk across the ramp.
406.4 Handrails. Handrails are not required on curb ramps.
406.5 Location at Marked Crossings. Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides.
406.6 Diagonal Curb Ramps. Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow. The bottom of diagonal curb ramps shall have 48 inches (1220 mm) minimum of clear space. Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1220 mm) minimum clear space within the markings. Diagonal curb ramps with flared sides shall have a segment of straight curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing.
406.7 Islands. Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and shall have a level area at least 48 inches (1220 mm) long minimum by 36 inches (915 mm) wide minimum in the part of the island intersected by the crossings.
407.1 General. New elevators required to be accessible shall comply with 407.2. New destination-oriented elevators required to be accessible shall comply with 407.3. New limited use/limited application elevators required to be accessible shall comply with 407.4. Altered elements of existing elevators shall comply with 407.5.
407.2 New Elevators. New accessible elevators shall comply with 407.2.1 through 407.2.13 and with ASME/ANSI A17.1. They shall be passenger elevators as classified by ASME/ANSI A17.1.
407.2.1 Automatic Operation. Elevator operation shall be automatic. Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to zero loading conditions.
407.2.2 Call Buttons. Call buttons in elevator lobbies and halls shall be located vertically between 35 inches (890 mm) and 48 inches (1220 mm) above the floor, measured to the centerline of the button. A clear floor space complying with 305 shall be provided. Such call buttons shall have visible signals to indicate when each call is registered and when each call is answered. Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension. The button that designates the up direction shall be located above the button that designates the down direction. Buttons shall be raised or flush. Objects located beneath hall call buttons shall protrude 4 inches (100 mm) maximum into the clear floor space.
407.2.3 Hall Signals. A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the direction of travel. Alternatively, in-car signals shall be located in cars, visible from the floor area adjacent to the hall call buttons, and shall comply the requirements of this section.
407.2.3.1 Audible Signals. Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that state the word "up" or "down." Audible signals or verbal annunciators shall have a frequency of 1500 Hz maximum. The audible signal or verbal annunciator shall be 20 dBA minimum and 80 dBA maximum, measured at the annunciator.
407.2.3.2 Visible Signals. Visible signals shall comply with 407.2.3.2.1 through 407.2.3.2.3.
407.2.3.2.1 Height. Hall signal fixtures shall be centered at 72 inches (1830 mm) minimum above the floor or ground.
407.2.3.2.2 Size. The visible signal elements shall be 2-1/2 inches (64 mm) minimum in the smallest dimension.
407.2.3.2.3 Visibility. Signals shall be visible from the floor area adjacent to the hall call button.
407.2.4 Tactile Signs on Hoistway Entrances. Tactile character and Braille floor designations shall be provided on both jambs of elevator hoistway entrances and shall be 60 inches (1525 mm) above the floor, measured from the baseline of the characters. A tactile star shall also be provided on both jambs at the main entry level. Such characters shall be 2 inches (51 mm) high and shall comply with 703.2.
407.2.5 Doors. Elevator doors shall be the horizontal type. Elevator hoistway and car doors shall open and close automatically. Elevator doors shall be provided with a reopening device that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person. The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) and 29 inches (735 mm) above the floor. The device shall not require physical contact to be activated, although contact may occur before the door reverses. Door reopening devices shall remain effective for 20 seconds minimum.
407.2.6 Door and Signal Timing for Hall Calls. The minimum acceptable time from notification that a car is answering a call or designation of which car is assigned to a lobby destination floor entry until the doors of that car start to close shall be calculated from the following equation:
T = D/(1.5 ft/s) or T = D/(455 mm/s) = 5 seconds minimum
where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway door. For cars with in-car lanterns, T begins when the signal is visible from the point 60 inches (1525 mm) directly in front of the farthest hall call button and the audible signal is sounded.
407.2.7 Door Delay for Car Calls. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum.
407.2.8 Inside Dimensions of Elevator Cars. Clear width of elevator doors and inside dimensions of elevator cars shall comply with Table 407.2.8.
MINIMUM DIMENSIONS | ||||
Door Location | Door Clear Width | Inside Car, Side to Side | Inside Car, Back Wall to Front Return | Inside Car, Back Wall to Inside Face of Door |
Centered | 42 inches (1065 mm) | 80 inches (2030 mm) | 51 inches (1295 mm) | 54 inches (1370 mm) |
Side (Off- centered) | 36 inches (915 mm)1 | 68 inches (1725 mm) | 51 inches (1295 mm) | 54 inches (1370 mm) |
Any | 36 inches (915 mm)1 | 54 inches (1370 mm) | 80 inches (2030 mm) | 80 inches (2030 mm) |
Any | 36 inches (915 mm)1 | 60 inches (1525 mm)2 | 60 inches (1525 mm)2 | 60 inches (1525 mm)2 |
407.2.9 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302. The clearance between the car platform sill and the edge of any hoistway landing shall be 1-1/4 inch (32 mm) maximum.
407.2.10 Illumination Levels. The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 footcandles (54 lux) minimum.
407.2.11 Car Controls. Elevator controls shall comply with 407.2.11.1 through 407.2.11.4.
407.2.11.1 Buttons. Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. Buttons shall be raised or flush. Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right. Keypads, where provided, shall be in a standard telephone keypad arrangement.
407.2.11.2 Designations and Indicators for Control Buttons. Control buttons shall be identified by tactile characters complying with 703.2. Characters and Braille shall be placed immediately to the left of the button to which the designations apply. The control button for the main entry floor and control buttons, other than remaining buttons with floor designations, shall be identified with tactile symbols as shown in Table 407.2.11.2. Buttons with floor designations shall be provided with visible indicators to show that a call has been registered. The visible indication shall extinguish when the car arrives at the designated floor. Where provided, telephone- style keypad buttons shall be identified by tactile characters complying with 703.2 except that Braille is not required. Characters shall be centered on the corresponding keypad button.
Control Button | Tactile Symbol | Braille Message |
Emergency Stop | [insert symbol] | [insert symbol] "ST"OP Three cells |
Alarm | [insert symbol] | [insert symbol] AL"AR"M Four cells |
Door Open | [insert symbol] | [insert symbol] OP"EN" Three cells |
Door Close | [insert symbol] | [insert symbol] CLOSE Five cells |
Main Entry Floor | [insert symbol] | [insert symbol] MA"IN" Three cells |
Phone | [insert symbol] | [insert symbol] PH"ONE" Four cells |
407.2.11.4 Location. Controls shall be located to accommodate a forward reach or side reach as specified in 308.
407.2.12 Car Position Indicators. In elevator cars, audible and visible car location indicators shall be provided.
407.2.12.1 Visible Indicators. Indicator shall be located above the car control panel or above the door. Numerals shall be 1/2 inch (13 mm) high minimum. As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate.
407.2.12.2 Audible Indicators. The audible signal shall be 20 dBA minimum and 80 dBA maximum, measured at the annunciator, and shall have a frequency of 1500 Hz maximum. The signal shall be an automatic verbal announcement which announces the floor at which the car has stopped except an audible signal which sounds as the car passes or stops at a floor served by the elevator shall be acceptable for elevators with a rated speed of 200 feet per minute (1.02 m/s) or less.
407.2.13 Emergency Communications. Emergency two-way communication systems between the elevator car and a point outside the hoistway shall comply with ASME/ANSI A17.1. The highest operable part of a two-way communication system shall be 48 inches (1220 mm) maximum above the floor. The device shall be identified by tactile characters complying with 703.2 located adjacent to the device. If the system uses a handset, the cord from the panel to the handset shall be at least 29 inches (735 mm) minimum. The car emergency signaling device shall not be limited to voice communication. If instructions for use are provided, essential information shall be presented in both tactile and visual form.
407.3 New Destination-Oriented Elevators. New accessible destination-oriented elevators shall comply with 407.2.1, 407.2.4 through 407.2.10, and 407.2.13. Such elevators shall also comply with 407.3.1 through 407.3.5 and ASME/ANSI A17.1. They shall be passenger elevators as classified by ASME/ANSI A17.1.
407.3.1 Call Buttons. Call buttons shall be located vertically between 35 inches (890 mm) and 48 inches (1220 mm) above the floor, measured to the centerline of the button. A clear floor space complying with 305 shall be provided. Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension. Buttons shall be raised or flush. Objects located beneath hall call buttons shall protrude 4 inches (100 mm) maximum into the clear floor space. A keypad or other means for the entry of destination information shall be provided. Keypads, where provided, shall be in a standard telephone keypad arrangement. Visible and audible signals which indicate which elevator car to enter shall be provided.
407.3.2 Hall Signals. A visible and audible signal shall be provided to indicate a car destination corresponding with 407.3.1. The audible tone and verbal announcement shall be the same as those given at the call button or call button keypad. Each elevator in a bank shall have audible and visible means for differentiation.
407.3.2.1 Visible Signals. Visible signals shall comply with 407.3.2.1.1 through 407.3.2.1.3.
407.3.2.1.1 Height. Hall signal fixtures shall be centered at 72 inches (1830 mm) minimum above the floor or ground.
407.3.2.1.2 Size. The visible signal elements shall be 2-1/2 inches (64 mm) minimum in the smallest dimension.
407.3.2.1.3 Visibility. Signals shall be visible from the floor area adjacent to the hoistway entrance.
407.3.3 Car Controls. Emergency controls, including the emergency alarm, shall have their centerlines 35 inches (890 mm) minimum and 48 inches (1220 mm) maximum above the floor. Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. Buttons shall be raised or flush. Controls shall be located to accommodate a forward reach or side reach as specified in 308.
407.3.4 Car Position Indicators. In elevator cars, audible and visible car location indicators shall be provided.
407.3.4.1 Visible Indicators. Indicators shall be located above the car control panel or above the door. Numerals shall be 1/2 inch (13 mm) high minimum. A display shall be provided in the car with visible indicators to show car destinations. The visible indicators shall extinguish when the call has been answered.
407.3.4.2 Audible Indicators. An automatic verbal announcement which announces the floor at which the car has stopped shall be provided. The announcement shall be 20 dBA minimum and 80 dBA maximum, measured at the annunciator.
407.3.5 Elevator Car Identification. In addition to the tactile signs required by 407.2.4, a tactile elevator car identification shall be placed immediately below the hoistway entrance floor designation. The characters shall be 2 inches (51 mm) high and shall comply with 703.2.
407.4 New Limited-Use/Limited-Application Elevators. New accessible limited-use/limited application elevators shall comply with 407.4.1 through 407.4.10 and shall comply with ASME/ANSI A17.1, Part XXV.
407.4.1 Automatic Operations. Elevator operation shall be automatic. Each car shall automatically stop at a floor landing within a tolerance of 1/2 inch (13 mm) under rated loading to zero loading conditions.
407.4.2 Call Buttons. Call buttons in elevator lobbies and halls shall be located vertically between 35 inches (890 mm) and 48 inches (1220 mm) above the floor, measured to the centerline of the button. Such call buttons shall have visible signals to indicate when each call is registered and when each call is answered. Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension, and shall be raised or flush. The button that designates the up direction shall be located above the button that designates the down direction. Objects located beneath hall call buttons shall protrude into the floor area adjacent to the hoistway entrance 4 inches (100 mm) maximum.
407.4.3 Hall Signals. A visible and audible signal complying with 407.2.3 shall be provided in the car or at each hoistway entrance to indicate the direction of travel.
407.4.4 Tactile Signs on Hoistway Entrances. Tactile character and Braille floor designations shall be provided on both jambs of elevator hoistway entrances and shall be 60 inches (1525 mm) above the floor measured from the baseline of the characters. Such characters shall be 2 inches (51 mm) high and shall comply with 703.2.
407.4.5 Doors. Elevator hoistway doors shall be either swinging or horizontally sliding type. Elevator hoistway and car doors shall open and close automatically. Horizontally sliding type hoistway and car doors shall comply with 407.2.5. Swinging hoistway doors shall conform to 404. Swinging doors shall be low energy power-operated and shall comply with ANSI/BHMA A156.1.9 Power operated swing doors shall remain open for 20 seconds minimum when activated.
407.4.6 Inside Dimensions of Elevator Cars. Elevator cars shall provide a clear width of 42 inches (1065 mm) minimum and a clear depth of 54 inches (1370 mm) minimum. For installations in existing buildings, elevator cars shall provide a clear width of 36 inches (915 mm) minimum, a clear depth of 54 inches (1370 mm) minimum, and a net clear platform area of 15 square feet (1.4 m2) minimum. Car doors shall be positioned at the narrow end of the car and shall provide a clear width of 32 inches (815 mm) minimum.
407.4.7 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302. The horizontal distance between the car platform sill and the edge of any hoistway landing shall be 1-1/4 inches (32 mm) maximum.
407.4.8 Illumination Levels. The level of illumination at the car controls, platform, and car threshold and landing sill shall be 5 footcandles (53.8 lux) minimum.
407.4.9 Car Controls. Elevator controls shall comply with 407.2.11.1 through 407.2.11.3. Controls shall be centered on a side wall and shall comply with 309.
407.4.10 Emergency Communications. Car emergency signaling devices complying with 407.2.13 shall be provided.
407.5 Existing Elevators. Altered elements of existing destination-oriented elevators shall comply with 407.3. Altered elements of existing limited-use/limited- application elevators shall comply with 407.4. Altered elements of all other existing elevators shall comply with 407.2.1, 407.2.4 , 407.2.6 , 407.2.7 , 407.2.9, 407.2.10 and 407.2.13 and with 407.5.1 through 407.5.7 or shall comply with 407.2. They shall be passenger elevators as classified by ASME/ANSI A17.1.
407.5.1 Call Buttons. Call buttons in elevator lobbies and halls shall be located vertically between 35 inches (890 mm) and 54 inches (1370 mm) above the floor, measured to the centerline of the button. A clear floor or ground space complying with 305 shall be provided. The button that designates the up direction shall be located above the button that designates the down direction. Keypad controls, if provided, shall comply with 407.2.11.
407.5.2 Hall Signals. A visible and audible signal at each hoistway entrance to indicate which car is answering a call or in-car signals complying with 407.2.3 shall be provided. Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that state the word "up" or "down". If new hall signals are installed, they shall comply with 407.2.3.
407.5.3 Door Operation. Power operated horizontally sliding car and hoistway doors opened and closed by automatic means shall comply with 407.2.5. Existing manually operated hoistway swing doors shall comply with 404.2.3 and 404.2.9. A power operated car door that opens and maintains a 32 inches (815 mm) minimum clear width shall be provided. Closing of the car door shall not be initiated until the hoistway door is closed. Car gates are prohibited.
407.5.5 Car Controls. Elevator controls shall comply with 407.5.5.1 through 407.5.5.4.
407.5.5.1 Buttons. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. Control buttons shall be raised, flush or recessed. Where the car operating panel is changed, control buttons shall comply with 407.2.11.1.
407.5.5.3 Height. Floor buttons shall be located 54 inches (1370 mm) maximum above the floor for parallel approach and 48 inches (1220 mm) maximum for front approach. Where the panel is changed, it shall comply with 407.2.11.3.
407.5.5.4 Operating Panels. Where a new car operating panel complying with 407.2.11 is provided, existing car operating panels not conforming to 407.2.11 shall not be required to be removed.
407.5.6 Car Position Indicators. Where a new car position indicator is provided, the indicator shall comply with 407.2.12.
407.5.7 Identification. Accessible elevators shall be clearly identified with the International Symbol of Accessibility complying with 703.7 unless all elevators in the building are accessible.
408 Wheelchair (Platform) Lifts
408.1 General. Wheelchair (platform) lifts shall comply with ASME/ANSI A17.1 and with 302 , 305 and 309. Wheelchair (platform) lifts shall not be attendant- operated and shall provide unassisted entry and exit from the lift.
408.2 Doors and Gates. Where a lift does not allow a user to pass through the lift, the lift shall have power- operated doors or gates. Where automatic doors or gates are provided, they shall be low energy power- operated and shall comply with ANSI/BHMA A156.9. Power operated doors and gates shall remain open for 20 seconds minimum when activated.
409 Accessible Means of Egress
409.1 General. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components: accessible routes complying with 402 , exit stairways complying with 409.2, elevators complying with 409.3, horizontal exits or smoke barriers. Wheelchair (platform) lifts shall not serve as part of an accessible means of egress.
410.1 General. Where areas of refuge are required, they shall comply with 410.
410.2 Location. Each area of refuge shall be accessed from the space it serves by an accessible route which serves as an accessible means of egress. The maximum travel distance to an area of refuge shall not exceed the travel distance permitted for the occupancy by the administrative authority. Every area of refuge shall have direct access to an exit stairway complying with 409.2 or an elevator complying with 409.3.
410.3 Size. Each area of refuge shall be sized to accommodate one wheelchair space complying with 305.3 for each 200 occupants or portion thereof, based on the occupant load of the area of refuge and all areas served by the area of refuge. Such wheelchair spaces shall not overlap the required means of egress width. Access to any required wheelchair space shall not be through more than one adjoining wheelchair space.
410.4 Construction. Each area of refuge shall be separated from the remainder of the story by a smoke barrier having a one-hour minimum fire-resistance rating. Smoke barriers shall extend to the floor or roof deck above. Doors in the smoke barrier shall have a 20 minute minimum fire-resistance rating. Doors shall be self-closing or automatic closing by smoke detection. HVAC openings in smoke barriers, where permitted, shall be ducted and provided with a smoke-actuated damper designed to resist the passage of smoke.
410.5.1 Elevator Lobby. Where an elevator lobby is used as an area of refuge, the elevator hoistway and lobby shall be pressurized to comply with the requirements for smokeproof enclosures, except where elevators are in an area of refuge formed by a horizontal exit or smoke barrier.
410.6 Communication System. Every area of refuge shall be provided with an accessible two-way communication system between the area of refuge and a central control point. The communication system shall have both audible and visible signals.
410.7 Instructions. In each area of refuge provided with a two-way communication system, instructions on the use of the area under emergency conditions shall be posted adjacent to the communications system. The instructions shall include:
410.8 Identification. Each area of refuge shall be identified by a tactile sign stating "Area of Refuge" complying with 703.2 and including the International Symbol of Accessibility complying with 703.7. A sign shall be located at each door providing access to the area of refuge. The sign shall be illuminated as required for exit signs where exit sign illumination is required.
501.1 Scope. General site and building elements required to be accessible by Chapter 2 shall comply with the applicable provisions of this chapter.
502.1 General. Car and van parking spaces required to be accessible shall comply with 502.
502.2 Vehicle Spaces. Car and van parking spaces shall be 96 inches (2440 mm) wide minimum and shall have an adjacent access aisle complying with 502.3.
502.3 Access Aisle. Access aisles serving parking spaces shall comply with 302 and 502.3.1 through 502.3.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle.
502.3.1 Width. Access aisles serving car parking spaces shall be 60 inches (1525 mm) wide minimum. Access aisles serving van parking spaces shall be 96 inches (2440 mm) wide minimum.
502.3.2 Length. Access aisles shall extend the full length of the parking spaces they serve.
502.3.3 Marking. Access aisles shall be marked so as to discourage parking in them.
502.4 Floor or Ground Surfaces. Parking spaces and access aisles serving them shall have surface slopes not steeper than 1:48 in all directions. Changes in level are not permitted. Access aisles shall be at the same level as the parking spaces they serve.
502.5 Vertical Clearance. Van parking spaces, access aisles serving them and a vehicular route to van parking spaces shall provide a vertical clearance of 98 inches (2490 mm) minimum.
502.6 Identification. Where accessible parking spaces are required to be identified by signs, the signs shall include the International Symbol of Accessibility complying with 703.7. Such signs shall be 60 inches (1525 mm) minimum above the floor or ground surface measured to the bottom of the sign.
503.1 General. Passenger loading zones required to be accessible shall comply with 503.
503.2 Vehicle Pull-up Space. Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) minimum in width, 20 feet (6100 mm) minimum in length and an adjacent access aisle complying with 503.3.
503.3 Access Aisle. Access aisles serving passenger loading zones shall comply with 302 and 503.3.1 through 503.3.3. Access aisles shall adjoin an accessible route.
503.3.1 Width. Access aisles serving vehicle pull- up spaces shall be 60 inches (1525 mm) wide minimum.
503.3.2 Length. Access aisles shall be 20 feet (6100 mm) minimum in length and shall extend the full length of the vehicle pull-up spaces they serve.
503.3.3 Marking. Access aisles shall be marked so as to discourage parking in them.
503.4 Floor and Ground Surfaces. Vehicle pull-up spaces and access aisles serving them shall have surface slopes not steeper than 1:48. Changes in level are not permitted. Access aisles shall be at the same level as the vehicle pull-up space they serve.
503.5 Vertical Clearance. Vehicle pull-up spaces, access aisles serving them and a vehicular route to the passenger loading zone shall provide a vertical clearance of 114 inches (2895 mm) minimum.
504.1 General. Stairs required to be accessible shall comply with 504.
504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) minimum in height and 7 inches (180 mm) maximum in height. Treads shall be 11 inches (280 mm) minimum in depth, measured from riser to riser.
504.3 Open risers. Open risers are not permitted.
504.4 Tread Surface. Stair treads shall comply with 302. Treads shall have a slope not steeper than 1:48. Changes in level are not permitted.
504.5 Nosings. The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum. Nosings that project beyond vertical risers shall have the underside of the leading edge curved or beveled. If not vertical, risers shall slope under the tread at an angle of 30 degrees maximum from vertical; however, the permitted projection of the nosing shall be 1-1/2 inches (38 mm) maximum beyond the rear of the tread below.
504.6 Handrails. Stairs shall have handrails complying with 505.
504.7 Outdoor Conditions. Outdoor stairs and outdoor approaches to stairs shall be designed so that water will not accumulate on walking surfaces.
505.1 General. Handrails required by 405 at ramps or 504 at stairs shall comply with 505.
505.4 Height. Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above stair nosings and ramp surfaces. Handrails shall be at a consistent height above stair nosings and ramp surfaces.
505.5 Clearance. Clearance between handrail and wall shall be 1-1/2 inches (38 mm) minimum.
505.7 Cross Section. Handrails shall have a circular cross section with an outside diameter of 1-1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum, or shall provide equivalent graspability in accordance with 505.7.1.
505.7.1 Non-Circular Cross Sections. Non- circular cross sections shall have a perimeter dimension of 4 inches (100 mm) minimum and 6- 1/4 inches (160 mm) maximum, and a cross-section dimension of 2-1/4 inches (57 mm) maximum.
505.8 Surfaces. Handrails and any wall or other surfaces adjacent to them shall be free of any sharp or abrasive elements. Edges shall have a 1/8 inch (3.2 mm) minimum radius.
505.9 Fittings. Handrails shall not rotate within their fittings.
505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. Such extension shall return to a wall, guard or the walking surface or shall be continuous to the handrail of an adjacent ramp run.
505.10.2 Top Extension at Stairs. At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing. Such extension shall return to a wall, guard or the walking surface or shall be continuous to the handrail of an adjacent stair flight.
505.10.3 Bottom Extension at Stairs. At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing and an additional 12 inches (305 mm) minimum horizontally at a height equal to that of the sloping portion of the handrail as measured above the stair nosings. Such extension shall return to a wall, guard or the walking surface or shall be continuous to the handrail of an adjacent stair flight.
601.1 Scope. Plumbing elements and facilities required to be accessible by Chapter 2 shall comply with the applicable provisions of this chapter.
602 Drinking Fountains and Water Coolers
602.1 General. Fixed drinking fountains and water coolers required to be accessible shall comply with 307 and 602.
602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305.
602.2.1 Forward Approach. Where a forward approach is provided, the clear floor space shall be centered on the unit and shall include knee and toe clearance complying with 306.
602.2.2 Parallel Approach. Where a parallel approach is provided, the clear floor space shall be centered on the unit.
602.3 Controls and Operating Mechanisms. Controls and operating mechanisms shall comply with 309.
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the floor or ground.
602.5 Spout Location. Units with a parallel approach shall have the spout located 3-1/2 inches (90 mm) maximum from the front edge of the unit, including bumpers. Units with a forward approach shall have the spout located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers.
602.6 Water Flow. The spout shall provide a flow of water at least 4 inches (100 mm) high so as to allow the insertion of a cup or glass under the flow of water. Measured horizontally relative to the front face of the unit, the angle of the water stream from spouts located within 3 inches (75 mm) of the front of the unit shall be 30 degrees maximum and from spouts located between 3 inches (75 mm) and 5 inches (125 mm) from the front shall be 15 degrees maximum.
603.1 General. Toilet and bathing rooms required to be accessible shall comply with 603.
603.2.1 Wheelchair Turning Space. Wheelchair turning space complying with 304 shall be provided within the room.
603.2.2 Overlap. Required clear floor spaces, clearance around water closets, and wheelchair turning space shall be permitted to overlap.
603.3 Mirrors. Mirrors shall be mounted with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor.
603.4 Coat Hooks and Shelves. Accessible coat hooks provided within toilet rooms shall be located within one of the reach ranges specified in 308. Where provided, a fold-down shelf shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor.
604 Water Closets and Toilet Compartments
604.1 General. Water closets and toilet compartments required to be accessible shall comply with 604.
604.2 Location. The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be centered in the ambulatory accessible toilet compartment specified in 604.8.2.
604.3.1 Clearance. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall. No other fixtures or obstructions shall be located within the required water closet clearance.
604.3.2 Overlap. The required clearance around the water closet shall be permitted to overlap the fixture, associated grab bars, tissue dispensers, accessible routes, clear floor space required at other fixtures and the wheelchair turning space, except as modified herein.
604.5 Grab Bars. Grab bars for water closets shall comply with 609. Grab bars shall be provided on the rear wall and on the side wall closest to the water closet.
604.5.1 Side Wall. Side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall.
604.6 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
604.7 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the floor. There shall be a clearance of 1 1/2 inches (38 mm) minimum below and 12 inches (305 mm) minimum above the grab bar. Dispensers shall not be of a type that control delivery or that do not allow continuous paper flow.
604.8 Toilet Compartments. Accessible toilet compartments shall meet the requirements of 604.8.1 through 604.8.5. Compartments containing more than one plumbing fixture shall comply with 603.
604.8.1 Wheelchair Accessible Compartments.
604.8.1.1 Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water closets measured perpendicular to the rear wall.
604.8.1.2 Doors. Compartment doors shall not swing into the minimum required compartment area.
604.8.1.3 Approach. Compartments shall be arranged for left-hand or right-hand approach.
604.8.1.4 Toe Clearance. In wheelchair accessible compartments, the front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the floor and 6 inches (150 mm) deep minimum beyond the compartment-side face of the partition, exclusive of partition support members. Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted water closet. Toe clearance at the side partition is not required in a compartment greater than 66 inches (1675 mm) wide.
604.8.2 Ambulatory Accessible Compartments. Ambulatory accessible compartments shall be 60 inches (1525 mm) deep minimum and 36 inches (915 mm) wide. Compartment doors shall not swing into the minimum required compartment area.
604.8.3 Doors. Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the stall and any obstruction shall be a minimum of 42 inches (1065 mm). The door shall be hinged 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet. The door shall be self- closing. A door pull complying with 404.2.7 shall be placed on both sides of the door near the latch.
604.8.4 Grab Bars. Grab bars in toilet compartments shall comply with 609.
604.8.4.1 Wheelchair Accessible Compartments. A side-wall grab bar complying with 604.5.1 located on the wall closest to the water closet and a rear-wall grab bar complying with 604.5.2 shall be provided.
604.8.4.2 Ambulatory Accessible Compartments. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment.
604.8.5 Coat Hooks and Shelves. Accessible coat hooks provided within toilet compartments shall be located within one of the reach ranges specified in 308. When provided, a fold-down shelf shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor.
605.1 General. Urinals required to be accessible shall comply with 605.
605.2 Height. Urinals shall be stall-type or wall-hung type with the rim 17 inches (430 mm) maximum above the floor or ground.
605.3 Clear Floor Space. A clear floor or ground space complying with 305 positioned for forward approach shall be provided. This clear space shall adjoin or overlap an accessible route.
605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.4 and shall be 44 inches (1120 mm) maximum above the floor or ground.
606.1 General. Sinks, lavatory fixtures, vanities and built-in lavatories required to be accessible shall comply with 606.
606.4 Faucets. Faucets shall comply with 309. Hand- operated, self-closing faucets shall remain open for at least 10 seconds.
606.5 Bowl Depth. The bowl shall be 6-1/2 inches (165 mm) deep maximum. Multiple compartment sinks shall have at least one compartment complying with this requirement.
606.6 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.
607.1 General. Bathtubs required to be accessible shall comply with 607.
607.2 Clear Floor Space. Clearance in front of bathtubs shall extend the length of the tub and shall be 30 inches (760 mm) wide minimum. A lavatory complying with 606 shall be permitted at the foot end of the clear floor space. Where a permanent seat is provided at the head end of the tub, the clear floor space shall extend a minimum of 12 inches (305 mm) beyond the seat.
607.3 Seat. A permanent seat at the head end of the tub or a removable in-tub seat shall be provided. Seats shall comply with 610.
607.4.1 Bathtubs With Permanent Seats. For bathtubs with permanent seats, grab bars shall be provided in accordance with 607.4.1.1 and 607.4.1.2.
607.4.1.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.3 and the other located 9 inches (230 mm) above the rim of the tub. Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the foot end wall.
607.4.1.2 Foot End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the foot end wall at the front edge of the tub.
607.4.2 Bathtubs Without Permanent Seats. For bathtubs without permanent seats, grab bars shall be provided in accordance with 607.4.2.1 through 607.4.2.3.
607.4.2.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.3 and other located 9 inches (230 mm) above the rim of the tub. Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the foot end wall.
607.4.2.2 Foot End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the foot end wall at the front edge of the tub.
607.4.2.3 Head End Wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the tub.
607.5 Controls. Controls, other than drain stoppers, shall be located on an end wall above the tub rim and below the grab bars, and between the front edge of the tub and the mid-point of the width of the tub. Controls shall comply with 309.4.
607.6 Shower Unit. A shower spray unit with a hose at least 59 inches (1500 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided. If an adjustable-height shower head mounted on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars.
607.7 Bathtub Enclosures. Enclosures for bathtubs shall not obstruct controls or transfer from wheelchairs onto bathtub seats or into tubs. Enclosures on bathtubs shall not have tracks mounted on the rim of the open face of the tub.
608.1 General. Shower compartments required to be accessible shall comply with 608.
608.2 Size and Clearances for Shower Compartments.
608.2.1 Transfer-type Shower Compartments. Transfer-type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) inside finished dimension measured at the centerpoint of opposing sides and shall have a minimum 36 inch (915 mm) wide entry on the face of the shower compartment. Clear floor space of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided.
608.2.2 Standard Roll-in-type Shower Compartment. Standard roll-in type shower compartments shall be 30 inches (760 mm) minimum by 60 inches (1525 mm) minimum clear inside dimension measured at the centerpoint of opposing sides and shall have a minimum 60 inches (1525 mm) wide entry on the face of the shower compartment. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clear floor space shall be provided adjacent to the open face of the shower compartment. A lavatory complying with 606 shall be permitted at the end of the clear space, opposite the shower compartment end where the seat is mounted and opposite the shower compartment side where shower controls are located.
608.2.3 Alternate Roll-in-type Shower Compartment. Alternate roll-in shower compartments shall be 36 inches (915 mm) in width and 60 inches (1220 mm) minimum in depth. A 36 inch (915 mm) wide minimum entry shall be provided to one side of the stall. The shower unit and controls shall be mounted on the end wall furthest from the compartment entry.
608.3.1 Transfer Type Showers. Grab bars shall be extended across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
608.4 Seats. An attachable or integral seat shall be provided in transfer-type shower compartments. A folding seat shall be provided in roll-in showers used in accessible transient lodging guest rooms. Seats shall comply with 610.
608.5 Controls. Shower or tub/shower facilities shall deliver water that is thermal shock protected to 120�F maximum. Controls shall comply with 309.4. Controls in roll-in showers shall be located above the grab bar but no higher than 48 inches (1220 mm) above the shower floor. In transfer-type shower compartments, controls, faucets and the shower spray unit shall be mounted on the side wall opposite the seat 38 inches (965 mm) minimum to 48 inches (1220 mm) maximum above the shower floor.
608.6 Shower Spray Unit. A shower spray unit with a hose at least 59 inches (1500 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided. In transfer type showers, the controls and shower unit shall be located on the control wall within 15 inches (380 mm) left or right of the centerline of the seat. In roll-in type showers, shower spray units mounted on the back wall shall be mounted 27 inches (685 mm) maximum from the side wall. If an adjustable-height shower head mounted on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars.
608.7 Curbs. Thresholds in shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303.
608.8 Shower Enclosures. Enclosures for shower compartments shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats.
609.1 General. Grab bars in accessible toilet or bathing facilities shall comply with 609.
609.3 Position of Grab Bars. Grab bars shall be mounted in a horizontal position, 33 inches (840 mm) minimum to 36 inches (915 mm) maximum above the floor.
609.4 Surface Hazards. Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements. Edges shall have a radius of 1/8 inch (3.2 mm) minimum.
609.5 Fittings. Grab bars shall not rotate within their fittings.
609.6 Method of Mounting. Grab bars shall be mounted in any manner that provides a gripping surface at the locations specified in this standard and that does not obstruct the required clear floor space.
609.7 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 lb (1112 N) is applied at any point on the grab bar, fastener mounting device or supporting structure.
610.1 General. Seats in accessible bathtubs and shower compartments shall comply with 610.
610.2 Bathtub Seats. The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum to 16 inches (405 mm) maximum. The seat shall be capable of secure placement. The depth of a permanent seat at the head end of the bathtub shall be 15 inches (380 mm) minimum. The top of bathtub seats shall be 17 inches (430 mm) minimum to 19 inches (485 mm) maximum above the bathroom floor.
610.3 Shower Compartment Seats. Where a seat is provided in a roll-in shower compartment, it shall be a folding type and shall be mounted on the wall adjacent to the controls. Seats shall be L-shaped or rectangular. The top of the seat shall be 17 inches (430 mm) minimum to 19 inches (485 mm) maximum above the bathroom floor. In a transfer-type shower, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. In a roll-in-type shower, the seat shall extend from the control wall to a point within 3 inches (75 mm) of the minimum required seat wall width.
610.3.1 Rectangular Seats. The rear edge of the seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum to 16 inches (405 mm) maximum from the seat wall. The side edge of the seat shall be 1-1/2 inches (38 mm) maximum from the back wall of a transfer-type shower and 1-1/2 inches (38 mm) maximum from the control wall of a roll-in-type shower.
610.3.2 L-Shaped Seats. The rear edge of the seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum to 16 inches (405 mm) maximum from the seat wall. The rear edge of the "L" portion of the seat shall be 1 1/2 inches (38 mm) maximum from the wall and the front edge shall be 14 inches (355 mm) minimum to 15 inches (380 mm) maximum from the wall. The end of the "L" shall be 22 inches (560 mm) minimum to 23 inches maximum (585 mm) from the main seat wall.
610.4 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 lb (1112 N) is applied at any point on the seat, fastener mounting device or supporting structure.
611.1 General. Washing machines and clothes dryers required to be accessible shall comply with 611.
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance.
611.3 Operable Parts. Controls and operating mechanisms including doors, lint screens, detergent and bleach compartments shall comply with 309.
611.4 Height. Top loading machines shall have the door to the laundry compartment located 34 inches (865 mm) maximum above the floor. Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 34 inches (865 mm) maximum above the floor.
701.1 Scope. Communications features and elements required to be accessible by Chapter 2 shall comply with the applicable provisions of this chapter.
702.2 Audible Alarms. Audible alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dBA or exceeds any maximum sound level with a duration of 60 seconds by 5 dBA, whichever is louder. Sound levels for alarm signals shall not exceed 120 dBA.
702.3 Visual Alarms. Visual alarms shall comply with 702.3.1 through 702.3.6
702.3.1 Light Pulse Characteristics.
702.3.1.1 Type. The lamp shall be a xenon strobe type or equivalent.
702.3.1.2 Color. The color shall be clear or nominal white.
702.3.1.3 Flash Rate. The flash rate for an individual appliance shall be 1 Hz minimum and 2 Hz maximum over its rated voltage range.
702.3.1.4 Pulse Duration. The maximum pulse duration shall be two-tenths of one second with a maximum duty cycle of 40 percent. The pulse duration is defined as the time interval between initial and final points of 10 percent of maximum signal.
702.3.2 Dispersion. Light dispersion of wall mounted appliances shall comply with Table 702.3.2.1. Light dispersion of ceiling mounted appliances shall comply with Table 702.3.2.2.
Vertical Dispersion | Horizontal Dispersion | ||
Degrees from Horizontal | Percent of Rated | Degrees fromVertical | Percent of Rated |
0 | 100 | 0 | 100 |
5-30 | 90 | 5-25 | 90 |
35 | 65 | 30-45 | 75 |
40 | 46 | 50 | 55 |
45 | 34 | 55 | 45 |
50 | 27 | 60 | 40 |
55 | 22 | 65 | 35 |
60 | 18 | 70 | 35 |
65 | 16 | 75 | 30 |
70 | 15 | 80 | 30 |
75 | 13 | 85 | 25 |
80 | 12 | 90 | 25 |
85 | 12 | ||
90 | 12 |
Degrees from Vertical | Percent of Rated |
0 | 100 |
5-25 | 90 |
30-45 | 75 |
50 | 55 |
55 | 45 |
60 | 40 |
65 | 35 |
70 | 35 |
75 | 30 |
80 | 30 |
85 | 25 |
90 | 25 |
702.3.3.2 Ceiling-Mounted Appliances. Ceiling-mounted appliances shall be located on the ceiling. Where ceiling height exceeds 30 feet (9140 mm), appliances shall be suspended from the ceiling to a height of 30 feet (9140 mm) maximum above the finished floor.
702.3.4.1 General. The signal provided by the appliance or appliances shall be visible either by direct view or by reflection from all parts of the covered area. Multiple appliances within an area are permitted only where size, shape, building construction or furnishings prohibit total coverage by a single appliance. Where multiple appliances are provided in a single area to provide total area coverage, the appliances shall comply with one of the following: a maximum of two appliances located on opposite walls; the appliances shall have synchronized flashes, or; in rooms 80 feet (24 m) by 80 feet (24 m) or greater in size, more than two appliances located such that all appliances in any 135-degree field of view are spaced a minimum of 55 feet (17 m) from each other.
702.3.4.2 Wall mounted appliances. Spacing and minimum effective intensity for wall mounted appliances shall be in accordance with Table 702.3.4.2 provided the appliance is located at the midpoint of the longest side of the area served. Where the appliance is not located at the midpoint, the minimum effective intensity shall be based upon a maximum area of coverage equal to the distance to the opposite side of the area served or double the distance to the farthest adjacent side of the area served, whichever is greater.
Maximum Area of Coverage in Feet | Minimum Required Light Output (Effective Intensity) (candela) | ||
One Light Per Area | Two Lights Per Area | Four Lights Per Area | |
20 X 20 (6100 X 6100 mm) | 15 | Not Permitted | Not Permitted |
30 X 30 (9140 X 9140 mm) | 30 | 15 | Not Permitted |
40 X 40 (12 X 12 m) | 60 | 30 | Not Permitted |
50 X 50 (15 X 15 m) | 95 | 60 | Not Permitted |
60 X 60 (18 X 18 m) | 135 | 95 | Not Permitted |
70 X 70 (21 X 21 m) | 185 | 95 | Not Permitted |
80 X 80 (24 X 24 m) | 240 | 135 | 60 |
90 X 90 (27 X 27 m) | 305 | 185 | 95 |
100 X 100 (30 X 30 m) | 375 | 240 | 95 |
110 X 110 (34 X 34 m) | 455 | 240 | 135 |
120 X 120 (37 X 37 m) | 540 | 305 | 135 |
130 X 130 (40 X 40 m) | 635 | 375 | 185 |
702.3.4.3 Ceiling mounted appliances. Spacing and minimum effective intensity for ceiling mounted appliances shall be in accordance with Table 702.3.4.3 provided the appliance is located at the centerpoint of the area served. Where the appliance is not located at the centerpoint, the minimum effective intensity shall be based upon a maximum area of coverage equal to two times the distance from the appliance to the farthest side of the area served.
Maximum Area of Coverage in Feet | Minimum Required Light Output (Effective Intensity) (candela) | |
Maximum Ceiling Height in Feet | One Light | |
20 X 20 (6100 X 6100 mm) | 10 (3050 mm) | 15 |
30 X 30 (9140 X 9140 mm) | 10 (3050 mm) | 30 |
40 X 40 (12 X 12 m) | 10 (3050 mm) | 60 |
50 X 50 (15 X 15 m) | 10 (3050 mm) | 95 |
20 X 20 (6100 X 6100 mm) | 20 (6100 mm) | 30 |
30 X 30 (9140 X 9140 mm) | 20 (6100 mm) | 45 |
40 X 40 (12 X 12 m) | 20 (6100 mm) | 80 |
50 X 50 (15 X 15 m) | 20 (6100 mm) | 115 |
20 X 20 (6100 X 6100 mm) | 30 (9140 mm) | 55 |
30 X 30 (9140 X 9140 mm) | 30 (9140 mm) | 75 |
40 X 40 (12 X 12 m) | 30 (9140 mm) | 115 |
50 X 50 (15 X 15 m) | 30 (9140 mm) | 150 |
702.3.5 Corridor Spacing Allocation and Minimum Intensity. Corridors that are 20 feet (6100 mm) maximum in width shall comply with 702.3.5. Corridors exceeding 20 feet (6100 mm) in width shall comply with 702.3.4.
702.3.5.1 Appliance Spacing. Appliances shall be located 15 feet (4570 mm) maximum from each end of the corridor and shall be located 50 feet (15 m) minimum and 100 feet (30 m) maximum apart along the corridor. Interruptions to the concentrated viewing path by doors, elevation changes or other obstructions shall constitute the end of a corridor for purposes of this section.
702.3.5.2 Minimum Effective Intensity. Appliances shall have a minimum effective intensity of 15 candela.
702.3.6 Guest Rooms. Guest rooms required to have visual alarms shall comply with 702.3.6.1 through 702.3.6.3.
702.3.6.1 Activation. Where single or multiple-station smoke detectors are provided in the sleeping room or suite, a visual alarm that is activated upon activation of the smoke detectors shall be provided within the room or suite. Where a building fire alarm system is provided, a visual alarm that is activated upon activation of the system shall be provided within the room or suite. The signaling line or channel between the activating device of the appliance and the building fire alarm system shall be monitored for integrity by the building fire alarm system. Where the same appliance is used for visual notification of smoke detector and fire alarm system activation, activation of the room or suite smoke detectors shall not activate the building fire alarm system.
702.3.6.2 Location. In sleeping rooms or suites having a linear dimension exceeding 16 feet (4880 mm), the appliance shall be located 16 feet (4880 mm) maximum from the head end of the bed location, measured horizontally. Where a suite contains more than one sleeping room, an appliance shall be provided in each sleeping room.
702.3.6.3 Minimum Effective Intensity and Mounting Height. Wall mounted appliances located 24 inches (610 mm) minimum below the ceiling shall have a minimum effective intensity of 110 candela. Ceiling mounted appliances and wall mounted appliances located less than 24 inches (610 mm) below the ceiling shall have a minimum effective intensity of 177 candela.
703.1 General. Signs required to be accessible shall comply with 703.
703.2.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background.
703.2.2 Tactile Characters. Tactile characters shall be raised 1/32 inch (0.8 mm) minimum above their background. Raised borders and decorative elements that are not required shall be separated 3/8 inch (9.5 mm) minimum from tactile characters.
703.2.3 Character Forms. Fonts shall have characters complying with 703.2.3.1 through 703.2.3.5.
703.2.3.1 Case. Characters shall be uppercase.
703.2.3.2 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative or of other unusual forms.
703.2.3.3 Width. Character width shall be 55 per cent minimum and 110 per cent maximum the height of the character with the width based upon the uppercase letter "O" and the height based upon the uppercase letter "I".
703.2.3.4 Height. Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based upon the uppercase letter "I".
703.2.3.5 Stroke Thickness. For characters with rectangular cross sections, the stroke thickness of the uppercase letter "I" shall be 10 per cent minimum and 15 per cent maximum of the height of the character. For characters with other cross sections, the stroke thickness of the uppercase letter "I" shall be 10 per cent minimum and 30 per cent maximum of the height of the character measured at the base of the cross section. Stroke thickness at the top of the cross section shall be 15 per cent maximum of the height of the character.
703.2.4 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters within a message, excluding word spaces. Where characters have rectangular cross sections, spacing between individual characters shall be 1/8 inch (3 mm) minimum to 3/8 inch (10 mm) maximum. Where characters have other cross sections, spacing between individual characters shall be 1/16 inch (2 mm) minimum to 3/8 inch (10 mm) maximum at the base of the cross sections and 1/8 inch (3 mm) to 3/8 inch (10 mm) maximum at the top of the cross sections.
703.2.5 Line Spacing. Spacing between the baselines of separate lines of characters in a sentence or paragraph shall be 135 per cent minimum and 170 per cent maximum of the character height.
703.3 Tactile Characters. Where tactile characters are required and separate tactile and visual characters with the same information are provided, tactile characters shall comply with 703.3.1 through 703.3.6 and visual characters shall comply with 703.4. Tactile characters shall be duplicated in Braille complying with 703.5.
703.3.1 Tactile Characters. Tactile characters shall be raised 1/32 inch (0.8 mm) minimum above their background. Raised borders and decorative elements that are not required shall be separated 3/8 inch (9.5 mm) minimum from tactile characters.
703.3.2 Character Forms. Fonts shall have characters complying with 703.3.2.1 through 703.3.2.5.
703.3.2.1 Case. Characters shall be uppercase.
703.3.2.2 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative or of other unusual forms.
703.3.2.3 Width. Character width shall be 55 per cent minimum and 110 per cent maximum the height of the character with the width based upon the uppercase letter "O" and the height based upon the uppercase letter "I".
703.3.2.4 Height. Character height measured vertically from the baseline of the character shall be 1/2 inch (13 mm) minimum and 3/4 inch (19 mm) maximum based upon the height of the uppercase letter "I".
703.3.2.5 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 15 per cent maximum of the height of the character.
703.3.3 Character Spacing. Character spacing shall be measured between the two closest points of adjacent character within a message, excluding word spaces. Spacing between individual characters shall be 1/8 inch (3 mm) minimum to 1/4 inch (6 mm) maximum.
703.3.4 Line Spacing. Spacing between the baselines of separate lines of characters in a sentence or paragraph shall be 135 percent minimum and 170 percent maximum of the character height.
703.4 Visual Characters. Visual characters required to be accessible shall comply with 703.4.1 through 703.4.5.
703.4.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background.
703.4.2 Character forms. Fonts shall have characters complying with 703.4.2.1 through 703.4.2.5.
703.4.2.1 Case. Characters shall be uppercase or lowercase or a combination thereof.
703.4.2.2 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative or of other unusual forms.
703.4.2.3 Width. Character width shall be 55 per cent minimum and 110 per cent maximum the height of the character with the width based upon the uppercase letter "O" and the height based upon the uppercase letter "I".
703.4.2.4 Height. Minimum character height measured from the baseline of the character shall comply with Table 703.4.2.4 based upon the height of the characters above the finished floor of the viewing location and the minimum viewing distance. Character height shall be based upon the uppercase letter "I". Minimum viewing distance is the horizontal distance where an obstruction prevents further approach towards the sign.
Height Above Floor to Baseline of Character | Minimum Viewing Distance | Minimum Character Height | Notes |
---|---|---|---|
< 40 inches (100 mm) | ---- | ---- | Not permitted except in elevators |
40 inches (100mm) to< 70 inches (1780 mm) | < 6 feet (1830 mm) | 5/8 inch (1 mm) | |
> 6 feet (1830 mm) | 5/8 inch (1 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 6 feet (1830 mm) | ||
> 70 inches (1780 mm) to < 120 inches (3050 mm) | < 15 feet (4570 mm) | 2 inches (51 mm) | |
> 15 feet (4570 mm) | 2 inches (51 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 15 feet (4570 mm) | ||
> 120 inches (3050 mm) | < 21 feet (6400 mm) | 3 inches (75 mm) | |
> 21 feet (6400 mm) | 3 inches (75 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 21 feet (6400 mm) |
703.4.2.5 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 per cent minimum and 30 per cent maximum of the height of the character.
703.4.3 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 per cent minimum and 35 per cent maximum of character height.
703.4.4 Line Spacing. Spacing between the baselines of separate lines of characters shall be 135 per cent minimum and 170 per cent maximum of the character height.
703.4.5 Mounting Height. Visual characters shall be located 40 inches (1015 mm) minimum above the floor of the viewing position. Mounting heights shall comply with Table 703.4.2.4 based on the size of the characters on the sign.
703.5 Braille. Tactile characters shall be accompanied by Grade II Braille complying with Table 703.5 and 703.5.1 through 703.5.3. Braille dots shall have a domed or rounded shape.
Measurement Range for: | Minimum in Inches | Maximum in Inches |
Dot base diameter | 0.059 (1.5 mm) | 0.060 (1.5 mm) |
Distance between any two dots in the same cell, measured center to center | 0.090 (2.3 mm) | 0.100 (2.5 mm) |
Distance between corresponding dots in adjacent cells, measured center to center | 0.241 (6.1 mm) | 0.300 (7.6 mm) |
Dot height | 0.025 (0.6 mm) | 0.031 (0.8 mm) |
Distance between corresponding dots from one cell directly below, measured center to center | 0.395 (10 mm) | 0.400 (10.2 mm) |
703.5.2 Raised Borders and Decorative Elements. Raised borders and decorative elements that are not required, shall be separated 3/8 inch (9.5 mm) minimum from Braille.
703.6 Pictograms. Where pictograms are required to be accessible, they shall comply with 703.6.1 through 703.6.3.
703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters or Braille shall not be located in the pictogram field.
703.6.2 Finish and Contrast. Pictograms and their field shall have a non-glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a dark pictogram on a light field.
703.6.3 Text Descriptors. Where text descriptors for pictograms are required, they shall located directly below or adjacent to the pictogram and shall comply with 703.2.
703.7 Symbols of Accessibility. Where symbols of accessibility are required, they shall comply with 703.7.1 through 703.7.2.
703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have a non- glare finish. Symbols of accessibility shall contrast with their background with either a light symbol on a dark background or a dark symbol on a light background.
703.7.2.1 International Symbol of Accessibility. Where the International Symbol of Accessibility is required, it shall be proportioned as shown in Figure 703.7.2.1. [insert figure]
703.7.2.2 International Symbol of TTY. Where the International Symbol of TTY is required, it shall be proportioned as shown in Figure 703.7.2.2. [insert figure]
703.7.2.3 Volume Controlled Telephones. Telephones required to have a volume control shall be identified by a sign containing a pictogram of a telephone handset with radiating sound waves on a square field as shown in Figure 703.7.2.3.[insert figure]
703.7.2.4 Assistive Listening Systems. Where assistive listening systems are required to be identified by the International Symbol of Access for Hearing Loss, it shall be proportioned as shown in Figure 703.7.2.4. [insert figure]
704.1 General. Public telephones required to be accessible shall comply with 704.
704.2 Wheelchair Accessible Telephones. Public telephones required to be wheelchair accessible shall comply with 704.2.1 through 704.2.6.
704.2.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided. The clear floor or ground space shall not be restricted by bases, enclosures or fixed seats.
704.2.1.1 Parallel Approach. Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum.
704.2.1.2 Forward Approach. Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum.
704.2.2 Controls and Operating Mechanisms. Controls and operating mechanisms shall comply with 309. Telephones shall have push-button controls where service for such equipment is available.
704.2.3 Protruding Objects. Telephones, enclosures and related equipment shall comply with 307.
704.2.4 Telephone Directories. Telephone directories, where provided, shall be located in accordance with 309.
704.2.5 Cord Length. The cord from the telephone to the handset shall be 29 inches (735 mm) long minimum.
704.2.6 Hearing Aid Compatibility. Telephones shall be hearing aid compatible.
704.3 Volume Control Telephones. Public telephones required to have volume controls shall be equipped with a receive volume control that provides 12 dB of gain minimum and up to 20 dB of gain maximum. An automatic reset shall be provided.
704.4 TTYs. TTYs required at a public pay telephone shall be permanently affixed within or adjacent to the telephone enclosure. Where an acoustic coupler is used, the telephone cord shall be sufficiently long to allow connection of the TTY and the telephone receiver.
704.5 TTY Shelf. Public pay telephones required to accommodate portable TTYs shall be equipped with a shelf and an electrical outlet within or adjacent to the telephone enclosure. The telephone handset shall be capable of being placed flush on the surface of the shelf. The shelf shall be capable of accommodating a TTY and shall have 6-inch (150 mm) minimum vertical clearance in the area where the TTY is to be placed.
705.1 General. Detectable warnings required on platform edges shall comply with 705.2, 705.3 or 705.4.
705.2 Truncated Domes. A 24-inch (610 mm) wide truncated dome surface complying with 705.2.1 through 705.2.3 shall be provided on the walking surface at the platform edge.
705.2.1 Dome Size. Domes shall have a diameter of 0.9 inch (23 mm), a height of 0.2 inch (5 mm) and a center-to-center spacing of 2.35 inches (60 mm).
705.2.2 Contrast. The truncated dome surface shall contrast visually with adjoining walking surfaces either light-on-dark or dark-on-light. The material used to provide contrast shall be an integral part of the truncated dome surface.
705.2.3 Interior Locations. Detectable warnings in interior locations shall differ from adjoining walking surfaces in resiliency or sound-on-cane contact.
705.3 Equivalent Tactile Surface. A 24 inch (610 mm) wide tactile surface shall be provided on the walking surface at the platform edge. The tactile surface shall provide equivalent detectability underfoot to that provided by 705.2.1 and shall provide contrast in accordance with 705.2.2.
705.4 Equivalent Detectability. Equivalent detectability of the platform edge by other construction, technology or means that will ensure equivalent or superior and reliable communication of the impending change to pedestrians who are blind or visually impaired. The information to be communicated must include 24 inches (610 mm) of advance warning of the platform edge and the precise orientation of the platform edge in relation to the pedestrian.
706 Assistive Listening Systems
706.1 General. Assistive listening systems required in assembly areas shall comply with 706.
706.2 Placement of Listening Systems. Individual fixed seats served by an assistive listening system shall have a complete view of the stage, playing area or cinema screen.
706.3 Types of Listening Systems. Induction loops, infrared systems, FM and AM radio frequency systems, hard-wired earphones and other equivalent devices shall be permitted as acceptable assistive listening systems.
706.4 Receiver Jacks. Receivers required for use with an assistive listening system shall include a 1/8-inch (3 mm) standard mono jack. Where other jack types are used, adapters shall be provided to comply with this provision.
706.5 Receiver Hearing Aid Compatibility. Receivers required to be hearing aid compatible shall interface with T-coils in hearing aids either through the provision of neck loops or a hearing aid compatible headset.
707 Automatic Teller Machines and Fare Machines
707.1 General. Automatic teller machines and fare machines required to be accessible shall comply with 707.
707.4 Input. Input devices shall comply with 707.4.1 through 707.4.5.
707.4.1 Privacy. The opportunity for the same degree of privacy of input shall be available to all individuals utilizing the equipment.
707.4.3 Separation Between Keys. Any key surface shall be separated from other key surfaces by 1/8 inch (3.2 mm) minimum. Function keys shall be separated from numeric keys by a distance that is not less than three times greater the distance between the numeric keys.
707.4.4 Numeric Keys. Where provided, numeric keys shall comply with 707.4.4.1 and 707.4.4.2.
707.4.4.1 Arrangement. Numeric keys shall be arranged in a 12-key telephone keypad layout with the number one key in the upper left hand corner.
707.4.4.2 Marking. The number five key shall have a single raised dot.
707.4.5 Function Keys. Where provided, function keys shall comply with 707.4.5.1 through 707.4.5.3.
707.4.5.1 Arrangement. Function keys shall be arranged in the order of enter, clear, cancel, add value and decrease value horizontally from left to right or vertically from top to bottom. Where provided, add value and decrease value function keys shall be grouped with other function keys.
707.4.5.2 Marking. Function keys shall be marked with tactile characters as follows: Enter or proceed key: raised circle; Clear or correct key: raised vertical line or bar; Cancel key: raised ex; Add value key: raised plus sign; Decrease value key: raised minus sign.
707.4.5.3 Color Coding. Where function keys are color coded, they shall be colored as follows: Enter or proceed key: green; Clear or correct key: black; Cancel key: red; Add value key: blue; Decrease value key: yellow.
707.5 Output. Output devices shall comply with 707.5.1 through 707.5.6.
707.5.1 Privacy. The opportunity for the same degree of privacy of output shall be available to all individuals utilizing the equipment.
707.5.2 Operating Instructions. Machines shall provide visual and audible instructions for operation. Visual and audible instruction shall include all information required by 707.5.2.1 through 707.5.2.5.
707.5.2.1 Initiation. Instructions shall be able to be initiated by the user of the machine.
707.5.2.2. Expedited Process. After initiation, instructions shall be available for the experienced user to expedite the transaction.
707.5.2.3 Orientation. Orientation and assistance for unfamiliar users to the physical features of the machine, operational options and details for each function shall be provided.
707.5.2.4 Transaction Prompts. All transaction prompts within each operation shall be provided.
707.5.2.5 Input Verification. Verification of all user inputs shall be provided.
707.5.3 Audible Instruction. Audible instruction shall be provided through a standard audio mini jack, a telephone handset, a wireless transmission system or another mechanism that is readily available to all customers.
707.5.4 Video Display Screen. The video display screen shall comply with 707.5.4.1 and 707.5.4.2.
707.5.4.2 Characters. Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) minimum in height based upon the uppercase letter "I". Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background.
707.5.5 Dispensing of Bills. Machines that dispense paper currency shall dispense the currency in descending order with the lowest denomination on top.
707.5.6 Receipts and Verification. Where a receipt is available and is requested, the following options shall be provided: a printed receipt, audible presentation of the transaction information provided on the receipt, or both.
801.1 Scope. Special rooms and spaces required to be accessible by Chapter 2 shall comply with the applicable provisions of this chapter.
802 Wheelchair Spaces in Assembly Areas
802.1 General. Wheelchair spaces required in assembly areas shall comply with 802.
802.2 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 and shall comply with 302. Changes in level are not permitted.
802.3 Width. A single wheelchair space shall be 36 inches (915 mm) minimum in width. Where multiple adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (840 mm) minimum in width.
802.4 Depth. Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) minimum in depth. Where a wheelchair space can only be entered from the side, the wheelchair space shall be 60 inches (1525 mm) minimum in depth.
802.5 Approach. One side of the wheelchair space shall adjoin an accessible route or adjoin another wheelchair space. Access to any wheelchair space shall not be through more than one adjoining wheelchair space.
802.6 Integral Part of Seating. Wheelchair spaces shall be an integral part of any fixed seating.
802.7 Companion Seat. At least one seat for a companion shall be provided beside each wheelchair space.
802.8 Lines of Sight. Wheelchair spaces shall provide lines of sight comparable to those of all viewing areas.
803 Dressing, Fitting, and Locker Rooms
803.1 General. Dressing, fitting, and locker rooms required to be accessible shall comply with 803.
803.2 Wheelchair Turning Space. Wheelchair turning space complying with 304 shall be provided within the room.
803.3 Doors. Doors shall not swing into any part of the wheelchair turning space.
803.4 Benches. A bench complying with 903 shall be provided within the room.
803.5 Coat Hooks and Shelves. Accessible coat hooks provided within the room shall be located within one of the reach ranges specified in 308. Where provided, a fold-down shelf shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor.
804 Medical Care Facility Patient or Resident Sleeping Rooms
804.1 General. Medical care facility and long term care facility patient or resident sleeping rooms required to be accessible shall comply with 804.
804.2 Wheelchair Turning Space. Wheelchair turning space complying with 304 shall be provided within the room and shall not overlap with or extend beneath a bed.
804.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
804.4 Toilet and Bathing Rooms. Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603.
804.5 Windows. Where operable windows are provided, at least one window shall comply with 309. Each window required to be operable by local code or regulation shall comply with 309.
805 Transient Lodging Guest Rooms
805.1 General. Transient lodging guest rooms required to be accessible shall comply with 805.2. Guest rooms required to have accessible communication features shall comply with 805.3.
805.2 Accessible Rooms. Accessible guest rooms shall comply with 805.2.1 through 805.2.6.
805.2.1 Living and Dining Areas. Living and dining areas shall be accessible.
805.2.2 Exterior Spaces. Exterior spaces, including patios, terraces and balconies, that are a part of the guest room shall be accessible.
805.2.4 Toilet and Bathing Facilities. Not less than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable provisions of Chapter 6. Required roll-in shower compartments shall comply with 608.2.2 or 608.2.3.
805.2.5 Kitchens, Kitchenettes and Wet Bars. Kitchens, kitchenettes and wet bars shall comply with 805.2.5.1 through 805.2.5.4.
805.2.5.1 Clear Floor Space. A clear floor space complying with 305 shall be provided at sinks, appliances, cabinets and counters.
805.2.5.2 Cabinets. At least 50 percent of shelf space in cabinets shall comply with 905.
805.2.5.4 Appliances. Controls and operating mechanisms of appliances shall comply with 309. At least 50 percent of shelf space in refrigerators and freezers shall be within at least one of the reach ranges in 308.
805.2.6 Windows. Where operable windows are provided, at least one window shall comply with 309. Each window required to be operable by local code or regulation shall comply with 309.
805.3 Communication Features. Guest rooms required to have accessible communication features shall comply with 805.3.1 and 805.3.2.
805.3.1 Alarms. Visual alarms complying with 702.3.6 shall be provided.
805.3.2 Notification Devices. Visual notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visual alarm signal appliances. Permanently installed telephones shall have volume controls complying with 704.3 and shall have an electrical outlet complying with 309 located within 48 inches (1220 mm) of the telephone to facilitate the use of a TTY.
901.1 Scope. Built-in furnishings and equipment required to be accessible shall comply with the applicable provisions of this chapter.
902 Seating at Tables, Counters and Work Surfaces
902.1 General. Seating at tables, counters and work surfaces required to be accessible shall comply with 902.
902.2 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided.
902.3 Height. The tops of tables and counters shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the floor or ground.
903.1 General. Benches required to be accessible shall comply with 903.
903.2 Clear Floor or Ground Space. Clear floor or ground space complying with 305 shall be provided and shall be positioned for parallel approach to an end of the bench seat.
903.3 Size. Benches shall have seats that are 20 inches (510 mm) minimum to 24 inches maximum (610 mm) in depth and 42 inches (1065 mm) minimum in length. Benches shall be fixed to a wall along the longer dimension.
903.4 Height. The bench seat shall be 17 inches (430 mm) minimum to 19 in (485 mm) maximum above the floor or ground.
903.5 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 lb (1112 N) is applied at any point on the seat, fastener mounting device or supporting structure.
903.6 Wet Locations. Where installed in wet locations, the surface of the bench shall be slip resistant and shall not accumulate water.
904 Sales and Service Counters
904.1 General. Counters required to be accessible shall comply with the applicable provisions of 904.
904.2 Approach. All portions of counters required to be accessible shall be located adjacent to a walking surface complying with 403.
904.3 Check-out Aisles. Check-out aisles required to be accessible shall comply with 904.3.1 and 904.3.2.
904.3.1 Aisle. Aisles shall comply with 403.
904.3.2 Counter. The counter surface height shall be 38 inches (965 mm) maximum above the finished floor or ground. The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface.
904.4 Point of Sales and Service Counters. Point of sales and service counters required to be accessible shall have a portion of the counter 36 inches (915 mm) minimum in length and 36 inches (915 mm) maximum in height above the finished floor or ground.
904.5 Food Service Lines. Counters in food service lines shall comply with 904.5.1 and 904.5.2.
904.5.1 Self-service shelves and dispensing devices. Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with 308.
904.5.2 Tray Slides. Tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the floor or ground.
905.1 General. Storage facilities required to be accessible shall comply with 905.
905.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided.
905.3 Height. Storage facilities shall comply with at least one of the reach ranges specified in 308. Clothes rods shall be 54 inches (1370 mm) maximum above the floor or ground.
905.4 Hardware. Hardware for storage facilities shall comply with 309.
1001.1 Scope. Every station, bus stop, bus stop pad, terminal building or other transportation facility shall comply with the applicable provisions of Chapters 2 through 9 and the applicable provisions of this chapter. Exception 1 in 206.2.3 does not apply to a terminal, depot or other station used for specified public transportation or to an airport passenger terminal.
1002.1 General. Bus stops and terminals shall comply with 1002.
1002.2 Bus Stop Pads. Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall comply with 1002.2.1 through 1002.2.4.
1002.2.1 Surface. Bus stop pads shall have a firm, stable surface.
1002.2.2 Dimensions. Bus stop pads shall have a clear length of 96 inches minimum measured from the curb or vehicle roadway edge and a clear width of 60 inches minimum measured parallel to the vehicle roadway to the maximum extent allowed by legal or site constraints.
1002.2.3 Connection. Bus stop pads shall be connected to streets, sidewalks or pedestrian paths by an accessible route complying with 402.
1002.2.4 Slope. The slope of the bus stop pad parallel to the roadway shall, to the extent practicable, be the same as the roadway. For water drainage, a maximum slope of 1:48 perpendicular to the roadway is allowed.
1002.3 Bus Shelters. Where provided, new or replaced bus shelters shall provide a minimum clear floor or ground space complying with 305. Such shelters shall be connected by an accessible route to the boarding area required by 1002.2.
1002.5 Bus Stop Siting. Bus stop sites shall be chosen such that, to the maximum extent practicable, the areas where lifts or ramps are to be deployed comply with 1002.2 and 1002.3.
1003 Fixed Facilities and Stations
1003.1 General. Fixed facilities and stations shall comply with the applicable provisions of 1003.
1003.2 New Construction. New stations in rapid rail, light rail, commuter rail, intercity bus, intercity rail, high speed rail and other fixed guideway systems shall comply with the 1003.2.1 through 1003.2.10.
1003.2.1 Station Entrances. Where different entrances to a station serve different transportation fixed routes or groups of fixed routes, at least one entrance serving each group or route shall comply with 402. All accessible entrances shall, to the maximum extent practicable, coincide with those used by the majority of the general public. In below ground subway stations, at least one entrance to each station shall comply with 402.
1003.2.2.2 Identification Signs. Stations covered by this section shall have identification signs complying with 703.4. Signs shall be clearly visible and within the sightlines of a standing or sitting passenger from within the train on both sides when not obstructed by another train.
1003.2.3 Fare Machines. Self-service fare vending, collection and adjustment machines shall comply with 707. Where self-service fare vending, collection or adjustment machines are provided for the use of the general public, at least one accessible machine of each type provided shall be provided at each accessible point of entry or exit.
1003.2.4 Detectable Warnings. Platform edges bordering a drop-off and not protected by platform screens or guard rails shall have a detectable warning complying with 705.
1003.2.6 TTYs: Where a public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one public TTY complying with 704.4 shall be provided in the station. Where four or more public pay telephones serve a particular entrance to a rail station, at least one TTY telephone complying with 704.4 shall be provided to serve that entrance.
1003.2.7 Track Crossings. Where it is necessary to cross tracks to reach boarding platforms, the route surface shall be level with the rail top at the outer edge and between the rails, except for a 2-1/2 inch (65 mm) maximum gap on the inner edge of each rail to permit passage of wheel flanges. Where gap reduction is not practicable, an above-grade or below-grade accessible route shall be provided.
1003.2.8 Public Address Systems. Where public address systems are provided to convey information to the public in terminals, stations or other fixed facilities, a means of conveying the same or equivalent information to persons with hearing loss or who are deaf shall be provided.
1003.2.9 Clocks. Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands, numerals and digits shall contrast with the background either light-on-dark or dark-on-light. Where clocks are mounted overhead, numerals and digits shall comply with 703.4.
1003.2.10 Escalators. Where provided in below grade stations, escalators shall have a clear width of 32 inches (815 mm) minimum.
1003.3 Existing Facilities: Key Stations. Rapid, light and commuter rail key stations, as defined under criteria established by the Department of Transportation in subpart C of 49 CFR part 37, and existing intercity rail stations shall comply with 1003.3.1 through 1003.3.3.
1003.3.1 Accessible Route. At least one accessible route from an accessible entrance to those areas necessary for use of the transportation system shall be provided. The accessible route shall include the features specified in 1003.2 , except that escalators shall not be required to comply with 1003.2.10. Where technical infeasibility in existing stations requires the accessible route to lead from the public way to a paid area of the transit system, an accessible fare collection machine complying with 1003.2.3 shall be provided along such accessible route.
1003.3.3 Direct Connections. New direct connections to commercial, retail or residential facilities shall, to the maximum extent feasible, have an accessible route complying with 402 from the point of connection to boarding platforms and all transportation system elements used by the public. Any elements provided to facilitate future direct connections shall be on an accessible route connecting boarding platforms and all transportation system elements used by the public.
1003.4 Existing Facilities: Alterations. For the purpose of complying with 202.4 , an area of primary function shall be as defined by applicable provisions of 49 CFR 37.43(c) (Department of Transportation's ADA Rule) or 28 CFR 36.403 (Department of Justice's ADA Rule).
1004.1 New Construction. New construction of airports shall comply with 1004.
1004.2 TTYs. Where public pay telephones are provided, at least one TTY shall be provided in compliance with 704.4. Additionally, if four or more public pay telephones are located in a main terminal outside the security areas, a concourse within the security areas, or a baggage claim area in a terminal, at least one public TTY complying with 704.4 shall also be provided in each such location.
1004.3 Terminal Information Systems. Terminal information systems that broadcast information to the general public through a public address system shall provide a means to provide the same or equivalent information to persons with a hearing loss or who are deaf.
1004.4 Clocks. Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands, numerals and digits shall contrast with their background either light-on-dark or dark-on-light. Where clocks are mounted overhead, numerals and digits shall comply with 703.4.
The Access Board should develop new figures for use with the revised ADAAG. Existing figures should be reviewed, improved, and edited or deleted as appropriate. New figures should be developed where appropriate.
The Committee recommends that the Access Board develop a comprehensive new commentary for the revised ADAAG. The Committee did not attempt to fully review or study existing "Appendix" language, or to draft new commentary language related to all revised ADAAG sections. However, the work of the Committee has created several sources of information that the Access Board should utilize in the development of the commentary, as follows:
The following includes all instances where the Full Committee recommends a specific action to the current appendix (new commentary).
201.3 Temporary Structures. Move existing sentence from 4.1.1(4) of current ADAAG to commentary. "Temporary buildings and facilities are not of permanent construction...."
1004.3 Terminal Information Systems. Move two sentences from current ADAAG 10.4.1(6) to commentary. "Such methods may include....."; "For persons with certain types..."
4.2.4.1 "Clear floor space accommodates a single stationary wheelchair and occupant."
4.27 Braille. "Case: The first letter of proper nouns and names and individual letters of the alphabet shall be displayed in upper case Braille."
4.33.6 Assistive Listening Systems. Placement - address placement of fixed seats served by systems.
4.33.7 Assistive Listening Systems. Intent, types of systems. Full paragraph from current ADAAG.
4.6.4 (Challenge C-33) Access Aisles. "Diagonal stripes, other means of clearly differentiating access aisles from parking spaces, or signs prohibiting parking in access aisles are examples of methods of discouraging parking in access aisles."
10.3.1(5) (Challenge C-54) Station Identification Signs. "Station identification signs should be placed at intervals in the station such that passengers in the vehicle will be able to see one when the vehicle is either stopped at the station or about to come to a stop in the station."
4.33.3 (Challenge CC-8) Dispersion of Wheelchair spaces. "This requirement should not be misinterpreted as a reverse scoping requirement on upper floor levels whether or not such elevator access is required by 4.1.3(5)."
4.28.3 (Challenge CC-7) Alarms. Develop text consistent with issues addressed in text approved by committee re: reasonable accommodation of employee by adding or removing visual alarm; potential effect of "cumulative" flash rate on persons with photosensitivity; sources of additional information.
4.1.3(8)(b) Current ADAAG text. "Because entrances also serve as emergency exits ..., it is preferable that all entrances be accessible." Committee notes point out that entrances are not always exits.
4.1.3(21) Current ADAAG text. "Examples of types of dressing rooms..."
4.5.1 Carpets. Delete all specific recommendations regarding slip resistance criteria. (Was approved by committee prior to December 1995 final report.)
1.0 Purpose. "This document does not contain technical criteria to specifically address the needs of persons with cognitive disabilities."
3.5 Definitions. Element - List of examples of elements.
3.5 Definitions. Sign - "Audible signs can be useful for presentation of certain information. Examples are wayfinding in cases where the destination is clearly visible or as a supplement to visual signs."
4.1.3(16)(a) Signs. "The use of pictograms and consistent, clear terms such as...." Committee report page 6.
4.34.1 General. "The equipment should not prevent users, including those with vision impairments....." Committee report page 49.
4.34.3 Input. "Private input means it is intended for the use of one individual at a time."
4.34.3.1 Keys. "It is intended that the user will hear a sound or discern a difference..." Committee report page 51.
4.34.4 Output. "Private output means it is intended for the use of one individual at a time."
4.34.4.2.1 Operating Instructions. "Verification of the PIN entered is considered to be achieved by the execution of the transaction. PIN Numbers should not..." Committee report page 54.
4.1.2(5)(e) Valet parking - "In rare cases where self-parking facilities are not possible..." Committee report page SO- P6.
4.6.3 Universal parking space - coordinate signs. Committee report page SO-P6.
4.6.4 Access Aisles. Coordinate access aisle language with text added by challenge. Committee report page SO-P7.
6.3(2) "In rooms with more than one bed, it is preferable that this space be located between beds." Relocated current ADAAG text.
4.1.1(3) Examples of work areas. Note: this was moved to commentary by Challenge S-5, but was never coordinated with the final Full Committee recommendation for "work stations." Committee report page SO-M5.
9.1.4 Room dispersion factors, Equivalent facilitation text. Challenge S-23 moved all to commentary. Committee report page SO-TL5,6.
4.1.3(21) "Examples of types of dressing rooms are those serving different genders or distinct and different functions as in different treatment or examination facilities." Committee report page SO-S&S-11.
5.5 "Food service lines. "...with a preferred clear width of 42 in (1065 mm) to allow passage around a person using a wheelchair." Committee report page SO-S&S-11.
7.2(3) Assistive Listening Systems. Relocate existing appendix text. Committee report page SO-S&S-11.
7.3 Check-out Aisles. "Examples of check-out aisles of different "design" include..." Relocated from current 7.3. Committee report page SO-S&S-11.
8.4 Card Catalogs. Move preferred height to commentary. Committee report page SO-S&S-11.
8.5 Stacks. Move preferred aisle width to commentary. Committee report page SO-S&S-11.
4.1.3(5) Add "stage lifts" to existing appendix text. Paragraph addressing current ADAAG exception 4 should be deleted - Committee deleted exception. Committee report page SO-A-11.
4.1.3(19)(a) Removable seat text - relocated. Committee report page SO-A-11.
4.1.3(19)(a) Seats with folding or removable armrests - delete. Committee report page SO-A-11.
4.33.1 Assembly seating. Minimum number - new paragraph. Committee report page SO-A-12.
4.33.2 Size of wheelchair spaces. Explanation of overlapping spaces. Committee report page SO-A-12.
4.33.2(3) Companion seating. "Companion seating is permitted to be furniture, fixed seating, removable or relocatable seating." Committee report page SO-A-12.
4.33.3 Revise title. (Coordinate with final report.) Committee report page SO-A-13.
4.33.3(4) Removable seats - relocated from 4.1.3(19)(a). - Note: Full committee deleted text addressing removable seats from guidelines. Committee report page SO-A-13.
4.33.3(3) Access to Performing Areas. Committee report page SO-A-13.
All dimensions shall be converted to equivalent metric dimensions in accordance with the following criteria:
Foot-inch dimension | Metric Rounding tolerance (Inches times 25.4, and round to:) |
< � inch | Nearest tenth of a millimeter |
� inch to < 3 inches | Nearest millimeter |
3 inches to < 10 feet | Nearest 5 millimeters |
10 feet to < approx. 33 feet | Nearest 10 millimeters |
Approx. 33 feet and greater | Nearest meter (where conversion exceeds 10,000 mm) |
< � inch | Expressed either as a fraction or decimal of an inch. Decimals shall not exceed three significant digits. (0.000) |
� inch to < 120 inches (10 feet) | Expressed in inches, with fractions of inches where applicable. |
> 120 inches (10 feet) | Expressed in feet without inches or decimals or expressed in inches |
< 10,000 mm (10 m) | Expressed in millimeters |
10,000 mm (10 m) or greater | Expressed in meters |
Dimensions shall either be "minimum", "maximum", or shall beconsidered absolute. No dimensions shall be stated as "nominal."