Cruise Ship: Seven Seas Voyager Cruise line: Radisson Seven Seas Cruises Inspection Date: 04/13/2004 Score: 100
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
10Swimming pools / spas maintained, safety equipment0
19Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored0
20PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated0
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits0
25Wiping cloths / chef=s towels clean, stored, used0
26Food-contact surfaces equipment / utensils clean; Safe0
27Equipment / utensils non-food-contact surfaces clean0
28Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency0
29Facilities convenient, accessible, designed, installed0
33Decks / bulkheads / deckheads construction, repair, clean0
34Plumbing fixtures / supply lines / drain lines / drains installed, repair0
36Lighting provided, shielded0
37Rooms / equipment vented, humidity, condensation0
999Miscellaneous0
Selected Item Details
Item No.: 10
Site: Other-MAIN POOL
Violation: A LENGTH OF ROPE WAS NOT ATTACHED TO THE FLOATATION DEVICE. A SHEPHERD'S HOOK WAS NOT PROVIDED AT THIS POOL.
Recommendation:Attach a lengh of rope 1.5 time the diameter of the pool to the floatation device. 6.4.1.2.1 Easy access shepherd's hook and approved floatation device shall be provided at a prominent location near each public swimming pool.
Site: Other-PORT WHIRLPOOL SPA
Violation: THE DRAIN COVER WAS CRACKED IN THIS SPA.
Recommendation:Replace the drain cover. Ensure that the replacement cover is anti-vortex in design.
Site: Other-WHIRLPOOL SPAS
Violation: THERE WERE SEVERAL DAYS WHERE THE PH LEVELS IN THE SPAS WERE TESTED AT 7.0 AND 8.0. AS PER THE ENGINEER, TEST STRIPS ARE USED AND THE SENSITIVITY LEVEL OF THE STRIPS MAY ACCOUNT FOR THESE RESULTS.
Recommendation:6.3.1.2.2 The whirlpool spa water shall be maintained with a pH between 7.2 and 7.8. Use an appropriate test kit to measure the pH levels in the whirlpool spas, and pools.
Site: Other-CREW POOL
Violation: AN ANTI-VORTEX DRAIN COVER WAS NOT PROVIDED AT THE CREW POOL. THIS WAS NOTED DURING THE LAST INSPECTION. THE CREW POOL WAS AN ADDITION AFTER THE CONSTRUCTION OF THE VESSEL. THE DRAIN COVER WAS ON ORDER AND SHOULD ARRIVE APRIL, 2004 IN FT. LAUDERDALE.
Recommendation:6.4.1.2.2 Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
Site: Other-WHIRLPOOL SPAS
Violation: CORE SAMPLES WERE NOT COLLECTED FOR THE SEDIMENTATION TESTS ON THE WHIRLPOOL GRANULAR FILTERS.
Recommendation:6.3.1.1.5 The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.