Cruise Ship Inspection Details

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: Aurora Cruise line: P & O Cruises Inspection Date: 01/31/2008 Score: 100
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
11Food handlers infections, communicable diseases0
16Potentially hazardous food temperatures storage, preparation display, service, transportation0
19Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored0
20PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated0
21Nonfood-contact surfaces designed, constructed, maintained, installed, located0
27Equipment / utensils non-food-contact surfaces clean0
33Decks / bulkheads / deckheads construction, repair, clean0
34Plumbing fixtures / supply lines / drain lines / drains installed, repair0
36Lighting provided, shielded0
Selected Item Details
Item No.: 08
Site: Potable Water-Oasis Spa
Violation: The backflow prevention device on the steam generator was leaking.
Recommendation:Replace the backflow prevention device.
Site: Potable Water-Cross1Connection Control Program
Violation: The backflow prevention devices for the cabin and public toilets were not listed on the cross1connection control program.
Recommendation:Ensure that all connections to the potable water system and the method of protection are listed on the cross-connection control program.
Site: Potable Water-Cross1Connection Control Program
Violation: The backflow prevention devices for the cabin and public toilets were not listed on the cross1connection control program.
Recommendation:Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Site: Potable Water-Tank Maintenance
Violation: There was no documentation for the drying and curing of the coating used in the potable water tanks. The coating, Interline 925, is approved for potable water tanks.
Recommendation:Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Site: Room Service-Deck 10 Bell Box
Violation: A leak was noted at the left backflow prevention device under the preparation sink.
Recommendation:Replace the backflow prevention device.
Site: Food Service General-
Violation: There were a few water boiler in food and housekeeping pantries where the potable water line was not fitted with a backflow prevention device.
Recommendation:Install a continuous pressure backflow prevention device on the potable water line to these boilers.
*Inspections scores of 85 or lower are NOT satisfactory