Cruise Ship Inspection Details

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: MSC Lirica Cruise line: MSC Cruises (Mediterranean Shipping Company) Inspection Date: 03/08/2007 Score: 98
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
12Hands washed; Hygienic practices0
13Management, knowledge, monitoring0
16Potentially hazardous food temperatures storage, preparation display, service, transportation0
19Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored2
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits0
26Food-contact surfaces equipment / utensils clean; Safe0
999Miscellaneous0
Selected Item Details
Item No.: 08
Site: Galley-Deck 5 Beverage Station
Violation: The back flow prevention device on the potable water line, serving the coffee machine, was leaking and water was noted pooling on the deck surface below. This unit was replaced at the time of the inspection.
Recommendation:Ensure that failed backflow prevention units are replaced.
Site: Potable Water-Spa Technical Rooms
Violation: The back flow prevention device intermediate atmospheric vent discharge port was directly connected to the waste drain line on both spa steam generators, defeating the air-gap and visual inspection of the units.
Recommendation:Ensure that air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch). Remove the direct connection between the intermediate atmospheric vent and the drain line.
Site: Potable Water-Engine Room - Potable Water Softeners
Violation: The backwash discharge pipe lines air-gaps that were less that twice the pipe diameter.
Recommendation:Ensure that air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).