FDA LogoU.S. Food and Drug AdministrationCenter for Food Safety and Applied Nutrition
U.S. Department of Health and Human Services
horizontal rule
Bacteriological Analytical Manual Online
January 2001

Appendix 1

Rapid Methods for Detecting Foodborne Pathogens

(Return to Table of Contents)

Introduction

Authors Note: This section differs from others in this manual in that it lists methods that are not necessarily used by FDA. In addition, the detailed protocols for these methods are not presented, and the user is referred to the instructions that accompany the test kits. One reason for this departure is the incremental rate of change and innovation in rapid testing technology. The best of these new techniques should be evaluated individually by user labs for their particular needs, and also collaboratively for possible adoption as official methods by the AOAC International (1).

The following text and tables list many of the commercially available rapid methods; they are classified by the principles underlying the procedure used. The assay principles and some of the detailed procedures are discussed in other chapters of this manual and/or in the literature cited in the tables. The AOAC status of rapid tests is indicated for those methods that have been validated or evaluated by AOAC (1) and have been adopted as AOAC Official methods. However, these methods continue to be modified or adapted, so that published information may not be the most current. Rapid methods are generally used as screening techniques, with negative results accepted as is, but positive results requiring confirmation by the appropriate official method, which, in many instances, is cultural. In many other instances, the rapid method has not been validated; therefore, the listing of a method or kit in this chapter in no way constitutes FDA recommendation or approval.

Rapid Methods

The rapid detection of pathogens and other microbial contaminants in food is critical for ensuring the safety of consumers. Traditional methods to detect foodborne bacteria often rely on time-consuming growth in culture media, followed by isolation, biochemical identification, and sometimes serology. Recent advances in technology make detection and identification faster, more convenient, more sensitive, and more specific than conventional assays -- at least in theory. These new methods are often referred to as "rapid methods", a subjective term used loosely to describe a vast array of tests that includes miniaturized biochemical kits, antibody- and DNA-based tests, and assays that are modifications of conventional tests to speed up analysis (8, 15, 16, 24, 36). Some of these assays have also been automated to reduce hands-on manipulations. With few exceptions, almost all assays used to detect specific pathogens in foods require some growth in an enrichment medium before analysis.

Experts who were surveyed in 1981 (19) about future developments in methods used for food microbiology, accurately predicted the widespread use of miniaturized biochemical kits for the identification of pure cultures of bacteria isolated from food. Most consist of a disposable device containing 15 - 30 media or substrates specifically designed to identify a bacterial group or species. With the exception of a few kits where results can be read in 4 hrs, most require 18-24 hrs incubation. In general, miniaturized biochemical tests are very similar in format and performance, showing 90-99% accuracy in comparison to conventional methods (5, 16, 21). However, kits that have been in use longer may have a more extensive identification database than newer tests. Most miniaturized kits are designed for enteric bacteria, but kits for the identification of non-Enterobacteriaceae are also available, including for Campylobacter, Listeria, anaerobes, non-fermenting Gram-negative bacteria and for Gram-positive bacteria (Table 1).

Advances in instrumentation have enabled automation of the miniaturized biochemical identification tests. These instruments can incubate the reactions and automatically monitor biochemical changes to generate a phenotypic profile, which is then compared with the provided database stored in the computer to provide an identification (8, 23, 35). Other automated systems identify bacteria based on compositional or metabolic properties, such as fatty acid profiles, carbon oxidation profiles (28) or other traits (Table 1).

Not forecast in that 1981 survey were the potential applications of immunological and genetic techniques in food microbiology (19). During the 1980s, major advances in basic research were transferred rapidly to applied areas, as "biotechnology" companies emerged and sought markets in the diagnostic field (11). DNA and antibody-based assays for numerous microbes or their toxins are now available commercially (12).

There are many DNA-based assay formats, but only probes, PCR and bacteriophage have been developed commercially for detecting foodborne pathogens. Probe assays generally target ribosomal RNA (rRNA), taking advantage of the fact that the higher copy number of bacterial rRNA provides a naturally amplified target and affords greater assay sensitivity (6, 14, 25, 37) (Table 2).

The basic principle of DNA hybridization is also being utilized in other technologies, such as the polymerase chain reaction (PCR) assay, where short fragments of DNA (probes) or primers are hybridized to a specific sequence or template, which is then enzymatically amplified by Taq polymerase using a thermocycler (2, 22). Theoretically, PCR can amplify a single copy of DNA by a million fold in less than 2 hrs; hence its potential to eliminate, or greatly reduce the need for cultural enrichment. However, the presence of inhibitors in foods and in many culture media can prevent primer binding and diminish amplification efficiency (26, 34), so that the extreme sensitivity achievable by PCR with pure cultures is often reduced when testing foods. Therefore, some cultural enrichment is still required prior to analysis (Table 2).

The highly specific interaction of phage with its bacterial host has also been used to develop assays for foodborne pathogens (38). One example is an assay for Salmonella, in which a specific bacteriophage was engineered to carry a detectable marker (ice nucleation gene). In the presence of Salmonella, the phage confers the marker to the host, which then expresses the phenotype to allow detection (Table 2).

The highly specific binding of antibody to antigen, especially monoclonal antibody, plus the simplicity and versatility of this reaction, has facilitated the design of a variety of antibody assays and formats, and they comprise the largest group of rapid methods being used in food testing (3, 10, 12, 33). There are 5 basic formats of antibody assays (12), the simplest of which is latex agglutination (LA), in which antibody-coated colored latex beads or colloidal gold particles are used for quick serological identification or typing of pure culture isolates of bacteria from foods (7, 12). A modification of LA, known as reverse passive latex agglutination (RPLA), tests for soluble antigens and is used mostly in testing for toxins in food extracts or for toxin production by pure cultures (12) (Table 3).

In the immunodiffusion test format, an enrichment sample is placed in a gel matrix with the antibody; if the specific antigen is present, a visible line of precipitation is formed (30).

The enzyme-linked immunosorbent assay (ELISA) is the most prevalent antibody assay format used for pathogen detection in foods (3, 33). Usually designed as a "sandwich" assay, an antibody bound to a solid matrix is used to capture the antigen from enrichment cultures and a second antibody conjugated to an enzyme is used for detection. The walls of wells in microtiter plates are the most commonly used solid support; but ELISAs have also been designed using dipsticks, paddles, membranes, pipet tips or other solid matrices (12) (Table 3).

Antibodies coupled to magnetic particles or beads are also used in immunomagnetic separation (IMS) technology to capture pathogens from pre-enrichment media (31). IMS is analogous to selective enrichment, but instead of using antibiotics or harsh reagents that can cause stress-injury, an antibody is used to capture the antigen, which is a much milder alternative. Captured antigens can be plated or further tested using other assays.

Immunoprecipitation or immunochromatography, still another antibody assay format, is based on the technology developed for home pregnancy tests. It is also a "sandwich" procedure but, instead of enzyme conjugates, the detection antibody is coupled to colored latex beads or to colloidal gold. Using only a 0.1 ml aliquot, the enrichment sample is wicked across a series of chambers to obtain results (9). These assays are extremely simple, require no washing or manipulation and are completed within 10 minutes after cultural enrichment (Table 3).

The last mentioned "category" of rapid methods includes a large variety of assays, ranging from specialized media to simple modifications of conventional assays, which result in saving labor, time, and materials. Some, for instance, use disposable cardboards containing dehydrated media, which eliminates the need for agar plates, constituting savings in storage, incubation and disposal procedures (4, 5). Others incorporate specialized chromogenic and fluorogenic substrates in media to rapidly detect trait enzymatic activity (13, 17, 20, 27, 29). There are also tests that measure bacterial adenosine triphosphate (ATP), which (although not identifying specific species), can be used to rapidly enumerate the presence of total bacteria (Table 4).

Applications and Limitations of Rapid Methods

Almost all rapid methods are designed to detect a single target, which makes them ideal for use in quality control programs to quickly screen large numbers of food samples for the presence of a particular pathogen or toxin. A positive result by a rapid method however, is only regarded as presumptive and must be confirmed by standard methods (11). Although confirmation may extend analysis by several days, this may not be an imposing limitation, as negative results are most often encountered in food analysis.

Most rapid methods can be done in a few minutes to a few hours, so they are more rapid than traditional methods. But, in food analysis, rapid methods still lack sufficient sensitivity and specificity for direct testing; hence, foods still need to be culture-enriched before analysis (12). Although enrichment is a limitation in terms of assay speed, it provides essential benefits, such as diluting the effects of inhibitors, allowing the differentiation of viable from non-viable cells and allowing for repair of cell stress or injury that may have resulted during food processing.

Evaluations of rapid methods show that some perform better in some foods than others. This can be attributed mostly to interference by food components, some of which can be especially troublesome for the technologies used in rapid methods. For example, an ingredient can inhibit DNA hybridization or Taq polymerase, but has no effect on antigen-antibody interactions and the converse situation may also occur (12). Since method efficiencies may be food dependent, it is advisable to perform comparative studies to ensure that a particular assay will be effective in the analysis of that food type.

The specificity of DNA based assays is dictated by short probes; hence, a positive result, for instance with a probe or primers specific for a toxin gene, only indicates that bacteria with those gene sequences are present and that they have the potential to be toxigenic. But, it does not indicate that the gene is actually expressed and that the toxin is made. Likewise, in clostridial and staphylococcal intoxication, DNA probes and PCR can detect only the presence of cells, but are of limited use in detecting the presence of preformed toxins (12).

Currently, there are at least 30 assays each for testing for E. coli O157:H7 and for Salmonella. Such a large number of options can be confusing and overwhelming to the user, but, more importantly, has limited the effective evaluation of these methods. As a result, only few methods have been officially validated for use in food testing (1,11).

Conclusions

As a rapid method is used more frequently, its benefits and at the same time, its limitations also become more apparent. This section only briefly described some of the rapid method formats and selected problems encountered when using these assays in food analysis. However, because of the complex designs and formats of these tests, coupled with the difficulties of testing foods, users must exercise caution when selecting rapid methods and to also evaluate these tests thoroughly, as some may be more suitable than others for distinct testing situations or for assaying certain types of food. Lastly, technology continues to advance at a great pace and next generation assays, such as biosensors (18) and DNA chips (32) already are being developed that potentially have the capability for near real-time and on-line monitoring of multiple pathogens in foods.


NOTE: The listings provided in Tables 1-4 are intended for general reference only and do not indicate endorsement or approval by FDA for use in food analysis.


Table 1. Partial list of miniaturized biochemical kits and automated systems for identifying foodborne bacteria* ( 5, 8, 15, 16, 21, 35, 36 ).
System Format Manufacturer Organisms
APIb biochemical bioMerieux Enterobacteriaceae, Listeria, Staphylococcus, Campylobacter, Non-fermenters, anaerobes
Cobas IDA biochemical Hoffmann LaRoche Enterobacteriaceae
Micro-IDb biochemical REMEL Enterobacteriaceae, Listeria
EnterotubeII biochemical Roche Enterobacteriaceae
Spectrum 10 biochemical Austin Biological Enterobacteriaceae
RapID biochemical Innovative Diag. Enterobacteriaceae
BBL Crystal biochemical Becton Dickinson Enterobacteriaceae, Vibrionaceae, Non-fermenters, anaerobes
Minitek biochemical Becton Dickinson Enterobacteriaceae
Microbact biochemical Microgen Enterobacteriaceae, Gram negatives, Non-fermenters, Listeria
Vitekb biochemicala bioMerieux Enterobacteriaceae, Gram negatives, Gram positives
Microlog C oxidationa Biolog Enterobacteriaceae, Gram negatives, Gram positives
MISb Fatty acida Microbial-ID Enterobacteriaceae, Listeria, Bacillus, Staphylococcus, Campylobacter
Walk/Away biochemicala MicroScan Enterobacteriaceae, Listeria, Bacillus, Staphylococcus, Campylobacter
Replianalyzer biochemicala Oxoid Enterobacteriaceae, Listeria, Bacillus, Staphylococcus, Campylobacter
Riboprinter nucleic acida Qualicon Salmonella, Staphylococcus, Listeria, Escherichia coli
Cobas Micro-ID biochemicala Becton Dickinson Enterobacteriaceae, Gram negatives, Non-fermenters
Malthusb conductancea Malthus Salmonella, Listeria, Campylobacter, E. coli, Pseudomonas, coliforms
Bactometer impedancea bioMerieux Salmonella
* Table modified from: Feng, P., App.I., FDA Bacteriological Analytical Manual, 8A ed.
a Automated systems
b Selected systems adopted AOAC Official First or Final Action.

NOTE: This table is intended for general reference only and lists known available methods. Presence on this list does not indicate verification, endorsement, or approval by FDA for use in food analysis.

 

Table 2. Partial list of commercially-available, nucleic acid-based assays used in the detection of foodborne bacterial pathogens* (2, 5, 8, 12, 14, 22, 25, 36, 37).
Organism Trade Name Format Manufacturer
Clostridium botulinum Probelia PCR BioControl
Campylobacter AccuProbe probe GEN-PROBE
GENE-TRAK probe Neogen
Escherichia coli GENE-TRAK probe Neogen
E. coli O157:H7 BAX PCRa Qualicon
Probelia PCR BioControl
Listeria GENE-TRAKc probe Neogen
AccuProbe probe GEN-PROBE
BAX PCR Qualicon
Probelia PCR BioControl
Salmonella GENE-TRAKc probe Neogen
BAX PCR Qualicon
BINDb phage BioControl
Probelia PCR BioControl
Staphylococcus aureus AccuProbe probe GEN-PROBE
GENE-TRAK probe Neogen
Yersinia enterocolitica GENE-TRAK probe Neogen
* Table modified from: Feng, P., App.I, FDA Bacteriological Analytical Manual, 8A ed.
a Polymerase chain reaction
b Bacterial Ice Nucleation Diagnostics
c Adopted AOAC Official First or Final Action

NOTE: This table is intended for general reference only and lists known available methods. Presence on this list does not indicate verification, endorsement, or approval by FDA for use in food analysis.

 

Table 3. Partial list of commercially-available, antibody-based assays for the detection of foodborne pathogens and toxins* (3, 5, 8, 12, 33, 36).
Organism/toxin Trade Name Assay Formata Manufacturer
Bacillus cereus diarrhoeal toxin TECRA ELISA TECRA
BCET RPLA Unipath
Campylobacter Campyslide LA Becton Dickinson
Meritec-campy LA Meridian
MicroScreen LA Mercia
VIDAS ELFAb bioMerieux
EiaFOSS ELISAb Foss
TECRA ELISA TECRA
Clostridium botulinum toxin ELCA ELISA Elcatech
C. perfringens enterotoxin PET RPLA Unipath
Escherichia coli
  EHEC**c O157:H7 RIM LA REMEL
E. coli O157 LA Unipath
Prolex LA PRO-LAB
Ecolex O157 LA Orion Diagnostica
Wellcolex O157 LA Murex
E. coli O157 LA TechLab
O157&H7 sera Difco
PetrifilmHEC Ab-blot 3M
EZ COLI Tube-EIA Difco
Dynabeads Ab-beads Dynal
EHEC-TEK ELISA Organon-Teknika
Assurancee ELISA BioControl
HECO157 ELISA 3M Canada
TECRA ELISA TECRA
E. coli O157 ELISA LMD Lab
Premier O157 ELISA Meridian
E. coli O157:H7 ELISA Binax
E. coli Rapitest ELISA Microgen
Transia Card E. coli O157 ELISA Diffchamb
E. coli O157 EIA/capture TECRA
VIPe Ab-ppt BioControl
Reveal Ab-ppt Neogen
Quix Rapid O157 Ab-ppt Universal HealthWatch
ImmunoCardSTAT Ab-ppt Meridian
VIDAS ELFAb bioMerieux
EiaFOSS ELISAb Foss
  Shiga toxin (Stx) VEROTEST ELISA MicroCarb
Premier EHEC ELISA Meridian
Verotox-F RPLA Denka Seiken
  ETEC c
  Labile toxin (LT) VET-RPLA RPLA Oxoid
  Stabile toxin (ST) E. coli ST ELISA Oxoid
Listeria Microscreen LA Microgen
Listeria Latex LA Microgen
Listeria-TEKe ELISA Organon Teknika
TECRAe ELISA TECRA
Assurancee ELISA BioControl
Transia Plate Listeria ELISA Diffchamb
Pathalert ELISA Merck
Listertest Ab-beads VICAM
Dynabeads Ab-beads Dynal
VIPe Ab-ppt BioControl
Clearview Ab-ppt Unipath
RAPIDTEST Ab-ppt Unipath
VIDASe ELFAb bioMerieux
EiaFOSS ELISAb Foss
UNIQUE Capture-EIA TECRA
Salmonella Bactigen LA Wampole Labs
Spectate LA Rhone-Poulenc
Microscreen LA Mercia
Wellcolex LA Laboratoire Wellcome
Serobact LA REMEL
RAPIDTEST LA Unipath
Dynabeads Ab-beads Dynal
Screen Ab-beads VICAM
CHECKPOINT Ab-blot KPL
1-2 Teste diffusion BioControl
SalmonellaTEKe ELISA Organon Teknika
TECRAe ELISA TECRA
EQUATE ELISA Binax
BacTrace ELISA KPL
LOCATE ELISA Rhone-Poulenc
Assurancee ELISA BioControl
Salmonella ELISA GEM Biomedical
Transia Plate Salmonella Gold ELISA Diffchamb
Bioline ELISA Bioline
VIDASe ELFAb bioMerieux
OPUS ELISAb TECRA
PATH-STIK Ab-ppt LUMAC
Reveal Ab-ppt Neogen
Clearview Ab-ppt Unipath
UNIQUEe Capture-EIA TECRA
Shigella Bactigen LA Wampole Labs
Wellcolex   Laboratoire Wellcome
Staphylococcus aureus Staphyloslide LA Becton Dickinson
AureusTeste LA Trisum
Staph Latex LA Difco
S. aureus VIA ELISA TECRA
  enterotoxin SET-EIA ELISA Toxin Technology
SET-RPLA RPLA Unipath
TECRAe ELISA TECRA
Transia Plate SE ELISA Diffchamb
RIDASCREEN ELISA R-Biopharm
VIDAS ELFAb bioMerieux
OPUS ELISAb TECRA
Vibrio cholera choleraSMART Ab-ppt New Horizon
bengalSMART Ab-ppt New Horizon
choleraScreen Agglutination New Horizon
bengalScreen Agglutination New Horizon
  enterotoxin VET-RPLAd RPLA Unipath
* Table modified from: Feng, P., App.I, FDA Bacteriological Analytical Manual, 8A ed.
a Abbreviations: ELISA, enzyme linked immunosorbent assay; ELFA, enzyme linked fluorescent assay; RPLA, reverse passive latex agglutination; LA, latex agglutination; Ab-ppt, immunoprecipitation.
b Automated ELISA
c EHEC - Enterohemorrhagic E. coli; ETEC - enterotoxigenic E. coli
d Also detects E. coli LT enterotoxin
e Adopted AOAC Official First or Final Action
** CAUTION: unless the assays claim that they are specific for the O157:H7 serotype, most of these tests detect only the O157 antigen; hence will also react with O157 strains that are not of H7 serotype. These O157, non-H7 strains, generally do not produce Shiga toxins and are regarded as not pathogenic for humans. Furthermore, some antibodies to O157 can also cross react with Citrobacter, E. hermanii and other enteric organisms.
NOTE: This table is intended for general reference only and lists known available methods. Presence on this list does not indicate verification, endorsement, or approval by FDA for use in food analysis.

 

Table 4. Partial list of other commercially available rapid methods and specialty substrate media for detection of foodborne bacteria* (4, 8, 13, 20, 27, 36).
Organism Trade Name Formata Assay Manufacturer
Bacteria Redigelb Media RCR Scientific
Isogridb HGMF QA Labs
Enliten ATP Promega
Profile-1 ATP New Horizon
Biotrace ATP Biotrace
Lightning ATP Idexx
Petrifilmb media-film 3M
Sim Plate media Idexx
Coliform/ E. coli Isogridb HGMF/MUG QA Labs
Petrifilmb media-film 3M
SimPlate media Idexx
Redigel Media RCR Scientific
ColiQuikc MUG/ONPG Hach
ColiBluec media Hach
Colilertb,c MUG/ONPG Idexx
LST-MUGb MPN media Difco & GIBCO
ColiCompleteb MUG-Xgal BioControl
Colitrak MPN-MUG BioControl
ColiGel & E*Colitec MUG-Xgal Charm Sciences
CHROMagar Medium CHROMagar
E. coli MUG disc MUG REMEL
CHROMagar Medium CHROMagar
  EHECd Rainbow Agar Medium Biolog
BCMO157:H7 Medium Biosynth
Fluorocult O157:H7 Medium Merck
Listeria monocytogenes BCM Medium Biosynth
Salmonella Isogridb HGMF QA Labs
OSRT Medium/ motility Unipath (Oxoid)
Rambach Medium CHROMagar
MUCAP C8esterase Biolife
XLT-4 Medium Difco
MSRVb Medium  
Yersinia Crystal violet Dye binding Polysciences
* Table modified from: Feng, P., App.I, FDA Bacteriological Analytical Manual, 8A ed.
a Abbreviations: APC, aerobic plate count; HGMF, hydrophobic grid membrane filter; ATP, adenosine triphosphate; MUG, 4-methylumbelliferyl-ß-D-glucuronide; ONPG, O-nitrophenyl ß-D-galactoside; MPN, most probable number.
b Adopted AOAC Official First or Final Action.
c Application for water analysis
d EHEC - enterohemorrhagic Escherichia coli
NOTE: This table is intended for general reference only and lists known available methods. Presence on this list does not indicate verification, endorsement, or approval by FDA for use in food analysis.

References

  1. Andrews, W.H. 1996. AOAC INTERNATIONAL"S three validation programs for methods used in the microbiological analysis of foods. Trend in Food Sci. Technol. 7:147-151.
  2. Barrett, T., P. Feng and B. Swaminathan. 1997. Amplification Methods for Detection of Foodborne Pathogens, pp.171-181. In: H.H. Lee, S.A. Morse and O. Olsvik (ed), Nucleic Acid Amplification Techniques: Application to Disease Diagnosis. Eaton Publishing, Boston.
  3. Candish, A.A.G. 1991. Immunological methods in food microbiology. Food Microbiol. 8:1-14.
  4. Chain, V.S., and D.Y.C. Fung. 1991. Comparison of Redigel, Petrifilm, spiral plate system, Isogrid, and aerobic plate count for determining the numbers of aerobic bacteria in selected foods. J. Food Prot. 54:208-211.
  5. Cox, N.A., D.Y.C. Fung, J.S. Bailey, P.A. Hartman, and P.C. Vasavada. 1987. Miniaturized kits, immunoassays and DNA hybridization for recognition and identification of foodborne bacteria. Dairy Food Sanit. 7:628-631.
  6. Curiale, M.S., M.J. Klatt, and M.A. Mozola. 1990. Colorimetric deoxyribonucleic acid hybridization assay for rapid screening of Salmonella in foods: Collaborative study. J. Assoc. Off. Anal. Chem. 73:248-256.
  7. D'Aoust, J.-Y., A.M. Sewell, and P. Greco. 1991. Commercial latex agglutination kits for the detection of foodborne Salmonella. J. Food Prot. 54:725-730.
  8. Dziezak, J.D. 1987. Rapid methods for microbiological analysis of foods. Food Technol. 41(7):56-73.
  9. Feldsine, P.T., R.L. Forgey, M.T. Falbo-Nelson and S. Brunelle. 1997. Escherichia coli O157:H7 Visual Immunoprecipitation assay: a comparative validation study. J. AOAC 80:43-48.
  10. Feng, P. 1992. Commercial assay systems for detecting foodborne Salmonella: a review. J. Food Prot. 55:927-934.
  11. Feng. P. 1996. Emergence of rapid methods for identifying microbial pathogens in foods. J. Assoc. Off. Anal. Chem. Int. 79:809-812.
  12. Feng, P. 1997. Impact of Molecular Biology on the Detection of Foodborne Pathogens. Mol. Biotech. 7:267-278.
  13. Feng, P.C.S., and P.A. Hartman. 1982. Fluorogenic assays for immediate confirmation of Escherichia coli. Appl. Environ. Microbiol. 43:1320-1329.
  14. Feng, P., K.A. Lampel and W.E. Hill. 1996. Developments in food technology: applications and economic and regulatory considerations, pp. 203-229. In: C.A. Dangler and B. Osburn (ed). Nucleic Acid Analysis: Principles and Bioapplications. Wiley & Sons, New York,
  15. Fung, D.Y.C. 1991. Rapid methods and automation for food microbiology, pp. 1-38. In: Instrumental Methods for Quality Assurance in Foods. D.Y.C. Fung and R.F. Matthews (eds). Marcel Dekker, New York.
  16. Fung, D.Y.C., N.A. Cox, and J.S. Bailey. 1988. Rapid methods and automation in the microbiological examination of food. Dairy Food Sanit. 8:292-296.
  17. Gaillot, O., P.D. Camillo, P. Berche, R. Courcol and C. Savage. 1999. Comparison of CHROMagar salmonella medium and Hektoen Enteric agar for isolation of salmonellae from stool samples. J. Clin. Microbiol. 37:762-765.
  18. Goldschmidt, M. 1999. Biosensors - scope in microbiological analysis, p. 268-278. In R.K. Robinson, C.A. Batt and P. Patel (ed.). Encyclopedia of Food Microbiology. Academic Press, London.
  19. Gutteridge, C.S., and M.L. Arnott. 1989. Rapid methods: an over the horizon view, pp. 297-319. In: Rapid Methods in Food Microbiology: Progress in Industrial Microbiology. M.R. Adams and C.F.A. Hope (eds). Elsevier, New York.
  20. Hartman, P.A. 1989. The MUG (glucuronidase) test for Escherichia coli in food and water, pp. 290-308. In: Rapid Methods and Automation in Microbiology and Immunology. A. Balows, R.C. Tilton, and A. Turano (eds). Brixia Academic Press, Brescia, Italy.
  21. Hartman, P.A., B. Swaminathan, M.S. Curiale, R. Firstenberg-Eden, A.N. Sharpe, N.A. Cox, D.Y.C. Fung, and M.C. Goldschmidt. 1992. Chapter 39, Rapid methods and automation, pp. 665-746. In: Compendium of Methods for the Microbiological Examination of Foods, 3rd ed., C. Vanderzant and D.F. Splittstoesser (eds). American Public Health Association, Washington, DC.
  22. Hill, W.E. 1996. The polymerase chain reaction: application for the detection of foodborne pathogens. CRC Crit. Rev. Food Sci. Nutrit. 36:123-173.
  23. Holmes, B. 1989. Comparative evaluation of the Roche Cobas IDA and Enterotube II systems for identifying members of the family Enterobacteriaceae. J. Clin. Microbiol. 27:1027-1030.
  24. Ibrahim, G.F. 1986. A review of immunoassays and their application to salmonellae detection in foods. J. Food Prot. 49:299-310.
  25. Kalamaki, M., R.J. Prioce and D.Y.C. Fung. 1997. Rapid methods for identifying seafood microbial pathogens and toxins. J. Rapid Methods and Automation in Microbiol. 5:87-137.
  26. Lampel, K.A., P. Feng and W.E. Hill. 1992. Gene probes used in food microbiology, pp. 151-188. In D. Bhatnagar and T.E. Cleveland (ed.), Molecular Approaches to Improving Food Safety. Van Nostrand Reinhold, New York, NY.
  27. Lantz, P-G., B. Hahn-Hagerdal, and P. Radstrom. 1994. Sample preparation methods in PCR-based detection of food pathogens. Trend Food Sci. Technol. 5:384-389.
  28. Manafi, M., W. Kneifel and S. Bascomb. 1991. Flurogenic and chromogenic substrates used in bacterial diagnostics. Microbiol. Rev. 55:335-348.
  29. Miller, J.M., and D.L. Rhoden. 1991. Preliminary evaluation of Biolog, a carbon source utilization method for bacterial identification. J. Clin. Microbiol. 29:1143-1147.
  30. Moberg, L.J., M.K. Wagner, and L.A. Kellen. 1988. Fluorogenic assay for rapid detection of Escherichia coli in chilled and frozen foods: collaborative study. J. Assoc. Off. Anal. Chem. 71:589-602.
  31. Oggel, J.J., D.C. Nundy, and C.J. Randall. 1990. Modified 1-2 test system as a rapid screening method for detection of Salmonella in foods and feeds. J. Food Prot. 53:656-658.
  32. Olsvik, O., T. Popovic, E. Skjerve, K.S. Cudjoe, E. Hornes, J. Ugelstad and M. Uhlen. 1994. Magnetic separation techniques in diagnostic microbiology. Clin. Microbiol. Rev. 7:43-54.
  33. Ramsay, G. 1998. DNA chips: State-of-the art. Nature Biotechnol. 16:40-44.
  34. Rose, S.A., and M.F. Stringer. 1989. Immunological methods, pp. 121-167. In: Rapid Methods in Food Microbiology: Progress in Industrial Microbiology. M.R. Adams and C.F.A. Hope (eds). Elsevier, New York.
  35. Rossen, L., P. Norskov, K. Holmstrom, O.F. Rasmussen. 1992. Inhibition of PCR by components of food samples, and DNA-extraction solutions. Int. J. Food Microbiol. 17:37-45.
  36. Stager, C.E., and J.R. Davis. 1992. Automated systems for identification of microorganisms. Clin. Microbiol. Rev. 5:302-327.
  37. Swaminathan, B. and P. Feng. 1994. Rapid Detection of Foodborne Pathogenic Bacteria. In: Annual Review of Microbiology, 48:401-426. Annual Reviews Inc., Palo Alto, CA.
  38. Tenover, F.C. 1988. Diagnostic deoxyribonucleic acid probes for infectious diseases. Clin. Microbiol. Rev. 1:82-101.
  39. Wolber, P.K. and R.L. Green. 1990. New rapid method for the detection of Salmonella in foods. Trends Food Sci. Technol. 1:80-82.

 

Hypertext Source: Bacteriological Analytical Manual, 8th Edition, Revision A, 1998. Revised 2000-July-18, Final Revision: 2001-Jan-25
Author:

Top

horizontal rule
horizontal rule