Health & Wellness Guidance Crosswalk
Meet Federal requirements and establish operational health and wellness goals by exploring how the Federal Guiding Principles for Sustainable Federal Buildings relate to standards, guidelines, and building rating systems. Choose the criteria that best suit your project to promote health and wellness as optimally as possible.
ASHRAE 189.1-2017 | DoD UFC 1-200-02 (Dec 2016) | Fitwel v2.0 | Green Globes | GSA PBS-P100 (Jul 2018) | LEED v4.1 | WELL v2 | |
---|---|---|---|---|---|---|---|
Air Quality and Control of TemperatureGP IV. Enhance Indoor Environmental Quality: Ventilation and Thermal ComfortProvision of ventilation systems, control of pollutants, IAQ management, and controls for occupant thermal comfort |
ASHRAE 189.1-2017
8 Indoor Environmental Quality (ASHRAE Standard 62.1, 62.2, and 170) & ASHRAE Standard 55
|
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5 Enhance Indoor Environmental Quality 3-5.1 Ventilation and Thermal Comfort |
Fitwel v2.0
6 Indoor Environment
7 Workspaces |
Green Globes
Existing Buildings
5.0 Indoor Environment 5.1 Ventilation System 5.6 Control of Pollutants at Source 5.7 IAQ Management |
GSA PBS-P100 (Jul 2018)
3.8.4 Health and Comfort: Environmental Controls
3.8.4.1 Ventilation and thermal comfort 5.2 Mechanical Performance Attributes 5.2.1 Temperature 5.2.2 Humidity Control 5.2.3 Air Movement 5.2.4 Pressure 5.2.5 Ventilation 5.2.6 Filtration |
LEED v4.1
O+M BD+C, ID+C Residential BD+C |
WELL v2
Air Features Thermal Comfort Features |
Air Quality and Exposure to Mold and MildewGP IV. Enhance Indoor Environmental Quality: Mold and MildewProvide policies and strategies for moisture control |
ASHRAE 189.1-2017
8 Indoor Environmental Quality
8.3.1.8 Building Entrance 8.3.6 Moisture Control |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-3 Ventilation Air and Building Envelope Requirements 3-5 Enhance Indoor Environmental Quality 3-5.3 Indoor Air Quality 3-5.3.1 Moisture Control |
Fitwel v2.0
6 Interior Environments
6.2 Asbestos-Safe Property: Provide an asbestos-free interior (Research related to health effects of dampness, mold, and dampness-related agents) 6.3 Indoor Air Quality Policy |
Green Globes
Existing Buildings
1.0 Energy 1.8 Envelope 1.16 Maintenance Schedules 5.0 Indoor Environment 5.1 Ventilation System 5.6 Control of Pollutants at Source |
GSA PBS-P100 (Jul 2018)
3.2.4 Moisture and Condensate Control
3.2.4.1 Moisture Control Opaque Assemblies 3.3 Prescriptive Enclosure Requirements 3.3.1 Moisture Control 3.3.4 Wall Systems 3.3.4.2 Materials with Organic Content 3.3.4.3 Air/Moisture Barrier System 3.5.2.27 Acoustical Ceilings: includes moisture resistance |
LEED v4.1
BD+C, ID+C Residential BD+C |
WELL v2
Air Features Water Features Thermal Comfort |
Air Quality and Exposure to RadonGP IV. Enhance Indoor Environmental Quality: RadonTest for radon in buildings to mitigate high levels from occupied spaces |
ASHRAE 189.1-2017
8 Indoor Environmental Quality
8.3.4 Soil-Gas Control 10.3.1.9 Soil-Gas Control |
Green Globes
Existing Buildings
4.0 Emissions, Effluents and Pollution Controls 4.7 Radon |
GSA PBS-P100 (Jul 2018)
3.3.3 Substructure: depressurization required when radon is present.
|
LEED v4.1
Residential BD+C
Indoor Environmental Quality Prerequisite: Radon-Resistant Construction |
WELL v2
Air Features
A01 Fundamental Air Quality (Precondition) - Part 4 |
||
Air Quality and Off-Gassing and Exposure to VOCsGP IV. Enhance Indoor Environmental Quality: Low-Emitting MaterialsSelection of low-emitting materials |
ASHRAE 189.1-2017
8 Indoor Environmental Quality
8.4.2 Materials 8.5.2 Materials |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5 Enhance Indoor Environmental Quality |
Fitwel v2.0
6 Indoor Environment
6.3 Adopt and implement an Indoor Air Quality (IAQ) policy for the building |
Green Globes
Existing Buildings New Construction |
GSA PBS-P100 (Jul 2018)
3.5 Interior Construction and Interior Finishes Performance Attributes
5.2 Mechanical Performance Attributes 5.2.5 Ventilation: 3 Tiers include low emitting materials requirements |
LEED v4.1
BD+C, Residential BD+C, ID+C O+M |
WELL v2
Air Features Materials Features |
Air Quality and PlantsGP IV. Enhance indoor Environmental Quality: PlantsProvide access to indoor and outdoor plants |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
3 Outdoor Spaces
6 Indoor Environment |
LEED v4.1
BD+C & ID+C (except Schools, Homes, and Midrise), O+M (except Schools), LEED for Schools, LEED for Homes and Midrise BD+C, Residential BD+C, ID+C |
WELL v2
Nourishment Feature Mind Feature |
|||
Air Quality in Occupied Buildings Under ConstructionGP IV. Enhance Indoor Environmental Quality: Indoor Air Quality during Building AlterationsControl of indoor air quality and impact on occupants during building alterations of existing spaces |
ASHRAE 189.1-2017
10 Construction and Plans for Operation
10.3.1.5 IAQ Construction Management 10.3.1.6 Moisture Control 10.3.1.7 Construction Activity Pollution Prevention: Idling of Construction Vehicles 10.3.1.8 Construction Activity Pollution Prevention: Protection of Occupied Spaces |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction
2-5 Enhance Indoor Environmental Quality 2-5.3.3 Protect Indoor Air Quality during Construction |
Fitwel v2.0
6 Indoor Environment
6.3 Adopt and implement an Indoor Air Quality (IAQ) policy for the building 6.4 Indoor Air Quality Testing |
Green Globes
Existing Buildings
5.0 Indoor Environment 5.6 Control of Pollutants at Source |
LEED v4.1
BD+C, ID+C Residential BD+C O+M |
WELL v2
Air Features
A04 Construction Pollution Management (Precondition) - Part 1 A10 Combustion Minimization (Optimization) - Part 1 |
|
Chemical Exposure from Pest Management ProgramsGP IV. Enhance Indoor Environmental Quality: Integrated Pest ManagementComplete and utilize an integrated pest management program within buildings |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5 Enhance Indoor Environmental Quality 3-5.3.3 Integrated Pest Management |
Fitwel v2.0
6 Indoor Environment
6.8 Integrated Pest Management |
Green Globes
Existing Buildings
4.0 Emissions, Effluents and Pollution Controls 4.13 Pesticides |
GSA PBS-P100 (Jul 2018)
2.5 Landscape Prescriptive Requirements
2.5.5 Pollinators 2.5.5.3 Supplemental Information and Other Considerations 2.5.5.3.4 Site Maintenance: includes IPM |
LEED v4.1
O+M
Indoor Environmental Quality Credit: Integrated Pest Management (IPM) |
WELL v2
Materials Features
X07 Pesticide Use (Optimization) - Part 1 |
|
Daylight and Circadian RhythmGP IV. Enhance Indoor Environmental Quality: DaylightProvide occupant access to daylight |
ASHRAE 189.1-2017
8 Indoor Environmental Quality
8.3.7 Glare Control 8.3.8 Occupant Override 8.4.1 Daylighting 8.4.1.1 Daylighting in Large Spaces Directly under a roof and Having High Ceilings 8.4.1.1.1 Minimum Daylight Area Table 8.4.1.2A 8.5 Performance Option 8.5.1 Daylight Simulation |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
3 Outdoor Spaces
7 Workspaces |
Green Globes
Existing Buildings
5.0 Indoor Environment 5.8 Lighting Features |
GSA PBS-P100 (Jul 2018)
3.7 Workplace Performance Requirements
3.8.4 Health and Comfort: Environmental Controls 3.8.4.2 Lighting/Daylighting: employee access to natural daylight 3.8.6.2 Partitions and interior walls: Maximize natural light through placement & colors 6.1 Lighting Performance Requirements 6.2 Lighting Performance Attributes 6.2.1 Lighting Quality - Interior Daylight (Table) 6.2.2 Lighting Quantity 6.3 Lighting Prescriptive Requirements 6.3.1 Indoor Lighting and Daylighting Criteria 6.3.2.5 Lighting Controls |
LEED v4.1
Residential BD+C
Indoor Environmental Quality Credit: Daylight Innovation Pilot: Daylight in nonregularly occupied spaces |
WELL v2
Light Feature
L01 Light Exposure and Education (Precondition) - Parts 1 & 2 L04 Glare Control (Optimization) - Part 1 L05 Enhanced Daylight Access (Optimization) - Parts 1 & 2 |
DietGP IV. Enhance Indoor Environmental Quality: Healthy Dining OptionsHealthy dining options |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5.4 Occupant Health and Wellness: Convenient Access to Healthy Dining Options |
Fitwel v2.0
10 Cafeteria and Prepared Food Retail (10.1 - 10.4)
11 Vending Machines and Snack Bars (11.1 - 11.4) |
LEED v4.1
BD+C & ID+C (except Schools, Homes, and Midrise), O+M (except Schools), LEED for Schools, LEED for Homes and Midrise
Innovation Pilot: Local Food Production |
WELL v2
Nourishment Feature
N01 Fruits and Vegetables (Precondition) - Parts 1 & 2 N02 Nutritional Transparency (Precondition) - Parts 1, 2, & 3 N03 Processed Foods (Optimization) - Parts 1, 2, & 3 N04 Food Advertising (Optimization) - Parts 1 & 2 N05 Artificial Ingredients (Optimization) - Part 1 N06 Portion Sizes (Optimization) - Part 1 N07 Nutrition Education (Optimization) - Part 1 N08 Mindful Eating (Optimization) - Parts 1 & 2 N09 Special Diets (Optimization) - Parts 1 & 2 N10 Food Preparation (Optimization) - Part 1 N11 Responsible Food Sourcing (Optimization) - Part 1 N12 Food Production (Optimization) - Parts 1 & 2 N13 Local Food Environment (Optimization) - Part 1 |
|||
DietGP IV. Enhance Indoor Environmental Quality: Potable WaterPotable water |
ASHRAE 189.1-2017
6 Water Use Efficiency
Limits on use of potable water for irrigation and in HVAC systems. Requirement for water bottle filling stations for half of all drinking fountains. |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5.4 Occupant Health and Wellness: Convenient Access to Potable Water |
Fitwel v2.0
9 Water Supply (9.1 - 9.2)
10 Cafeteria and Prepared Food Retail (10.4) 11 Vending Machines and Snack Bars (11.4) |
Green Globes
Existing Buildings |
GSA PBS-P100 (Jul 2018)
3.7. Workplace Performance Requirements
3.8.5 Health and comfort: Ergonomics 3.8.5.2 Building Amenities: filtered hot/cold water dispensers = one of the High Performance options |
LEED v4.1
BD+C, ID+C O+M, Residential BD+C |
WELL v2
Water Features
W01 Fundamental Water Quality (Precondition) - Parts 1, 2, & 3 W02 Water Contaminants (Precondition) - Parts 1, 2, 3, 4, 5, 6, & 7 W03 Legionella Control (Precondition) - Part 1 W04 Enhanced Water Quality (Optimization) - Part 1 W05 Water Quality Consistency (Optimization) - Parts 1 & 2 W06 Drinking Water Promotion (Optimization) - Part 1 |
ExerciseGP IV. Enhance Indoor Environmental Quality: Stairwells as a Desirable OptionStairwell vertical circulation |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
5 Stairs
|
GSA PBS-P100 (Jul 2018)
3.5 Interior Construction and Interior Finishes Performance Attributes
3.6.3 Promote the Use of Stairs |
LEED v4.1
BD+C, ID+C, O+M, Residential BD+C
Innovation Pilot: Design for Active Occupants |
WELL v2
Movement Features
V01 Active Buildings and Communities (Precondition) - Part 1 V03 Movement Network and Circulation (Optimization) - Parts 1, 2, & 3 V11 Physical Activity Promotion (Optimization) - Parts 1 & 2 V12 Self-Monitoring (Optimization) - Part 1 |
||
ExerciseGP IV. Enhance Indoor Environmental Quality: Active WorkstationsActive workstations |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
7 Workspaces
|
LEED v4.1
BD+C, ID+C, O+M, Residential BD+C
Innovation Pilot: Ergonomics approach for computer users. |
WELL v2
Movement Features
V01 Active Buildings and Communities (Precondition) - Part 1 V02 Visual and Physical Ergonomics (Precondition) - Parts 1, 2, 3, 4, & 5 V07 Active Furnishings (Optimization) - Part 1 V10 Enhanced Ergonomics (Optimization) - Part 1 |
|||
ExerciseGP IV. Enhance Indoor Environmental Quality: Fitness CentersAccess to fitness centers |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
3 Outdoor Spaces
8 Shared Spaces |
GSA PBS-P100 (Jul 2018)
3.8.5 Health and comfort: Ergonomics
3.8.5.2 Building Amenities: one of the High Performance options |
WELL v2
Movement Features
V06 Physical Activity (Optimizatoin) - Parts 1 & 2 V08 Physical Activity Spaces and Equipment (Optimizatoin) - Parts 1, 2, & 3 V11 Physical Activity Promotion (Optimizatoin) - Parts 1 & 2 V12 Self-Monitoring (Optimization) (Optimization) - Part 1 |
|||
ExerciseGP IV. Enhance Indoor Environmental Quality: Bicycle Commuter FacilitiesAccess to bicycle commuter facilities |
ASHRAE 189.1-2017
5.3.7 Mitigation of Transportation Impacts
5.3.7.1 Pedestrian and Bicycle Connectivity 5.3.7.2 Bicycle Parking |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
2 Building Access
|
Green Globes
Existing Buildings
1.0 Energy 1.18 Cycling Facilities |
GSA PBS-P100 (Jul 2018)
3.8.5 Health and comfort: Ergonomics
3.8.5.2 Building Amenities: one of the High Performance options |
LEED v4.1
BD+C NC, Residential BD+C, ID+C LEED for Communities, LEED for Cities O+M |
WELL v2
Movement Features
V01 Active Buildings and Communities (Precondition) - Part 1 V04 Active Commuter and Occupancy Support (Optimization) - Parts 1 & 2 |
ExerciseGP I. Employ Integrated Design Principles (NC): Sustainable LocationsMass transit / public transportation access & walkability |
ASHRAE 189.1-2017
5.3.7 Mitigation of Transportation Impacts
|
DoD UFC 1-200-02 (Dec 2016)
Chapter 5 Sustainable Installations Appendix B Best Practices |
Fitwel v2.0
1 Location
2 Building Access |
Green Globes
Existing Buildings
1.0 Energy 1.17 Public Transportation 1.19 Other Measures |
GSA PBS-P100 (Jul 2018)
Chapter 2 Urban Development and Landscape Design
2.1 Urban Planning and Public Use Performance Requirements 2.2.1 Sustainable Locations 2.2.1.2 Site Supports Transit-Use and Reduced Automobile Commuting 2.2.1.3 Site Supports Neighborhood Connectivity and Walkability 2.3 Urban Planning and Design, and Site Prescriptive Requirements |
LEED v4.1
BD+C, Residential BD+C, ID+C LEED for Communities, LEED for Cities O+M |
WELL v2
Movement Features
V01 Active Buildings and Communities (Precondition) - Part 1 V05 Site Planning and Selection (Optimization) - Parts 1, 2, 3, & 4 V08 Physical Activity Spaces and Equipment (Optimization) - Parts 1, 2, & 3 V09 Exterior Active Design (Optimization) - Parts 1 & 2 |
General Health & WellnessGP I. Employ Integrated Design Principles (NC) / Employ Integrated Assessment, Operation, and Management Principles (EB)Integrated team approach for assessment, operation and management of existing buildings |
ASHRAE 189.1-2017
Informative Appendix F: Integrated Design
|
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Assessment of Existing Buildings for High Performance and Sustainable Building (HPSB) Compliance |
Green Globes
New Construction Existing Buildings |
GSA PBS-P100 (Jul 2018)
Appendix A: Submission Requirements
Integrated Design Review A.3 New Construction and Modernization, Figure A-3 |
LEED v4.1
BD+C, ID+C Residential BD+C BD+C, ID+C, O+M O+M |
WELL v2
Community Feature
C02 Integrative Design (Precondition) - Parts 1, 2, 3, & 4 |
|
Potential Exposure and Risk to OccupantsGP V. Reduce the Environmental Impact of MaterialsUtilize LCA evaluation of products as a basis for product selection. Complete and utilize a Green Purchasing program. |
ASHRAE 189.1-2017
9 Materials and Resources
9.4 Prescriptive Option 9.4.1 Reduced Impact Materials 9.4.1.1 Recycled Content and Salvaged Material Content 9.4.1.2 Regional Materials 9.4.1.3 Biobased Products 9.4.1.4 Multiple-Attribute Product Declaration or Certification (EPD, NSF/ANSI Standards, Product Life Cycle) 9.5 Performance Option 9.5.1 Life-Cycle Assessment (LCA) |
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-6 Reduce Environmental Impact of Materials 3-6.1.1 Recycled Content 3-6.1.2 Biologically-Based Products 3-6.1.3 Other Sustainable Products 3-6.1.4 Ozone Depleting Substances 3-7 Address Climate Change Risk (risk assessment of location & mitigation plan) |
Fitwel v2.0
6 Indoor Environment
6.3 Indoor Air Quality (IAQ) Policy 6 Indoor Environment 6.6 Green Purchasing Policy |
Green Globes
New Construction Existing Buildings NOTE: As part of GBI/ANSI Revision Committee: Risk Assessment for materials is included in the draft. |
GSA PBS-P100 (Jul 2018)
3.4 Interior Performance Requirements: many specific materials requirements by building component (recycled, biobased, etc.), too numerous to list
3.5 Interior Construction and Interior Finishes Performance Attributes 5.2 Mechanical Performance Attributes 5.2.5 Ventilation: 3 tiers include low emitting materials requirements |
LEED v4.1
BD+C, ID+C Residential BD+C O+M |
WELL v2
Air Features Materials Features |
Smoking Reduction / CessationGP IV. Enhance Indoor Environmental Quality: Smoking RestrictionsRestrictions on smoking within buildings |
ASHRAE 189.1-2017
8.3.1.7 Environmental Tobacco Smoke
|
DoD UFC 1-200-02 (Dec 2016)
Chapter 3 Employ Integrated Assessment, Operation, and Management Principles
3-5.3.4 Environmental Tobacco Smoke Control |
Fitwel v2.0
3 Outdoor Spaces
4 Entrances and Ground Floor 6 Indoor Environment |
Green Globes
Existing Buildings
5.6 Control of Pollutants at Source |
LEED v4.1
BD+C, ID+C, O+M Residential BD+C Indoor Environmental Quality |
WELL v2
Air Feature Mind Feature |
|
Views of NatureGP IV. Enhance Indoor Environmental Quality: Exterior ViewsProvide access to quality exterior views |
DoD UFC 1-200-02 (Dec 2016)
Chapter 2 Building Design & Construction Chapter 3 Employ Integrated Assessment, Operation, and Management Principles |
Fitwel v2.0
7 Workspaces
7.2 - Views of Nature |
GSA PBS-P100 (Jul 2018)
3.7 Workplace Performance Attributes
3.7.6.2 Partitions and interior walls: Tier 3: Do not block access to views 6.2 Lighting Performance Attributes 6.2.1 Lighting Quality: 3 Tiers require access to views for 50-90% of regularly occupied areas |
LEED v4.1
BD+C, ID+C Indoor Environmental Quality Credit: Daylight and Quality Views Innovation Pilot: Designing with Nature, Biophilic Design for the Indoor Environment Pilot: Quality Views in Nonregularly Occupied Spaces
|
WELL v2
Light Feature Mind Feature |
Air Quality and Control of TemperatureGP IV. Enhance Indoor Environmental Quality: Ventilation and Thermal ComfortProvision of ventilation systems, control of pollutants, IAQ management, and controls for occupant thermal comfort |
|
|||||||
Air Quality and Exposure to Mold and MildewGP IV. Enhance Indoor Environmental Quality: Mold and MildewProvide policies and strategies for moisture control |
|
|||||||
Air Quality and Exposure to RadonGP IV. Enhance Indoor Environmental Quality: RadonTest for radon in buildings to mitigate high levels from occupied spaces |
|
|||||||
Air Quality and Off-Gassing and Exposure to VOCsGP IV. Enhance Indoor Environmental Quality: Low-Emitting MaterialsSelection of low-emitting materials |
|
|||||||
Air Quality and PlantsGP IV. Enhance indoor Environmental Quality: PlantsProvide access to indoor and outdoor plants |
|
|||||||
Air Quality in Occupied Buildings Under ConstructionGP IV. Enhance Indoor Environmental Quality: Indoor Air Quality during Building AlterationsControl of indoor air quality and impact on occupants during building alterations of existing spaces |
|
|||||||
Chemical Exposure from Pest Management ProgramsGP IV. Enhance Indoor Environmental Quality: Integrated Pest ManagementComplete and utilize an integrated pest management program within buildings |
|
|||||||
Daylight and Circadian RhythmGP IV. Enhance Indoor Environmental Quality: DaylightProvide occupant access to daylight |
|
|||||||
DietGP IV. Enhance Indoor Environmental Quality: Healthy Dining OptionsHealthy dining options |
|
|||||||
DietGP IV. Enhance Indoor Environmental Quality: Potable WaterPotable water |
|
|||||||
ExerciseGP IV. Enhance Indoor Environmental Quality: Stairwells as a Desirable OptionStairwell vertical circulation |
|
|||||||
ExerciseGP IV. Enhance Indoor Environmental Quality: Active WorkstationsActive workstations |
|
|||||||
ExerciseGP IV. Enhance Indoor Environmental Quality: Fitness CentersAccess to fitness centers |
|
|||||||
ExerciseGP IV. Enhance Indoor Environmental Quality: Bicycle Commuter FacilitiesAccess to bicycle commuter facilities |
|
|||||||
ExerciseGP I. Employ Integrated Design Principles (NC): Sustainable LocationsMass transit / public transportation access & walkability |
|
|||||||
General Health & WellnessGP I. Employ Integrated Design Principles (NC) / Employ Integrated Assessment, Operation, and Management Principles (EB)Integrated team approach for assessment, operation and management of existing buildings |
|
|||||||
Potential Exposure and Risk to OccupantsGP V. Reduce the Environmental Impact of MaterialsUtilize LCA evaluation of products as a basis for product selection. Complete and utilize a Green Purchasing program. |
|
|||||||
Smoking Reduction / CessationGP IV. Enhance Indoor Environmental Quality: Smoking RestrictionsRestrictions on smoking within buildings |
|
|||||||
Views of NatureGP IV. Enhance Indoor Environmental Quality: Exterior ViewsProvide access to quality exterior views |
|