3.1 : Commercial Sector Energy Consumption
3.1.4 |
2010 Commercial
Energy End-Use Splits, by Fuel Type (Quadrillion Btu) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Natural |
Fuel |
|
Other |
Renw. |
Site |
|
Site |
|
Primary |
Primary |
|
|
|
|
Gas |
Oil (1) |
LPG |
Fuel(2) |
En.(3) |
Electric |
|
Total |
Percent |
Electric (4) |
|
Total |
Percent |
Lighting |
|
|
|
|
|
|
|
1.19 |
|
1.19 |
13.6% |
| |
3.69 |
|
3.69 |
20.2% |
|
Space Heating |
|
1.65 |
0.22 |
|
0.06 |
0.11 |
0.28 |
|
2.33 |
26.6% |
| |
0.88 |
|
2.93 |
16.0% |
|
Space Cooling |
|
0.04 |
|
|
|
|
0.84 |
|
0.88 |
10.1% |
| |
2.60 |
|
2.64 |
14.5% |
|
Ventilation |
|
|
|
|
|
|
0.54 |
|
0.54 |
6.1% |
| |
1.66 |
|
1.66 |
9.1% |
|
Refrigeration |
|
|
|
|
|
|
0.39 |
|
0.39 |
4.5% |
| |
1.21 |
|
1.21 |
6.6% |
|
Water Heating |
|
0.44 |
0.03 |
|
|
0.03 |
0.09 |
|
0.58 |
6.7% |
| |
0.28 |
|
0.78 |
4.3% |
|
Electronics |
|
|
|
|
|
|
0.26 |
|
0.26 |
3.0% |
| |
0.81 |
|
0.81 |
4.4% |
|
Computers |
|
|
|
|
|
|
0.21 |
|
0.21 |
2.4% |
| |
0.66 |
|
0.66 |
3.6% |
|
Cooking |
|
|
0.18 |
|
|
|
|
0.02 |
|
0.20 |
2.3% |
| |
0.07 |
|
0.25 |
1.4% |
|
Other (5) |
|
|
0.30 |
0.01 |
0.14 |
0.05 |
0.01 |
0.69 |
|
1.20 |
13.7% |
| |
2.13 |
|
2.64 |
14.5% |
|
Adjust to SEDS
(6) |
0.68 |
0.25 |
|
|
|
0.02 |
|
0.95 |
10.9% |
| |
0.06 |
|
0.99 |
5.4% |
|
Total |
|
|
3.29 |
0.52 |
0.14 |
0.12 |
0.14 |
4.54 |
|
8.74 |
100% |
| |
14.05 |
|
18.26 |
100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note(s): |
1)
Includes (0.43 quad) distillate fuel oil and (0.08 quad) residual fuel oil.
2) Kerosene (0.01 quad) and coal (0.06 quad) are assumed attributable to
space heating. Motor gasoline (0.05 quad) assumed attributable to other
end-uses. 3) Comprised of (0.11 quad) biomass, (0.03 quad) solar water
heating, (less than 0.01 quad) solar PV, and (less than 0.01 quad) wind. 4)
Site-to-source electricity conversion (due to generation and transmission
losses) = 3.10. 5) Includes service station equipment, ATMs, telecommunications
equipment, medical equipment, pumps, emergency electric generators, combined
heat and power in commercial buildings, and manufacturing performed in
commercial buildings. 6) Energy adjustment EIA uses to relieve discrepancies
between data sources. Energy attributable to the commercial buildings sector,
but not directly to specific end-uses. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DOWNLOAD TABLE AS PDF XLS
Related Tables:
Sources:
| EIA, National Energy Modeling System (NEMS) for AEO 2012 Early Release, Jan. 2012
|
|
|
|
|
|