Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

OSHA Hazard Information Bulletins
Radiofrequency Radiation-caused Burns


September 5, 1990

MEMORANDUM FOR:

REGIONAL ADMINISTRATORS

THROUGH:

  • LEO CAREY
  • Director
  • Office of Field Programs

FROM:

  • THOMAS J. SHEPICH
  • Director
  • Directorate of Technical Support

SUBJECT:

  • Safety Hazard Information Bulletin on Radiofrequency Radiation-caused Burns

The Directorate of Technical Support issues Hazard Information Bulletins (HIBs) in accordance with OSHA Instruction CPL 2.65 to provide relevant information regarding unrecognized or misunderstood safety and health hazards, and/or inadequacies of materials, devices, techniques and engineering controls. HIBs are initiated based on information provided by the field staff, studies, reports and concerns expressed by safety and health professionals, employers and the public. Information is compiled based on a comprehensive evaluation of available facts, literature and in coordination with appropriate parties. HIBs do not necessarily reflect OSHA policy.

The San Francisco Regional Office has brought to our attention a potentially serious hazard involving burns on longshoremen caused by radiofrequency radiation. Two hazards were noted at this location. The burns were apparently caused by spark discharges from crane cables. Also present was an induced-current grasping hazard.

The longshoremen were working on a pier that is located in close proximity to several AM radio station transmitting towers. The radiofrequency radiation emanating from the transmitters induces electric currents in the longshoring operation cranes' cables due to the cables acting as antenna receptors to the radiation. The OSHA Health Response Team measured currents as high as 200 milliamps (mA). The American National Standards Institute C95 committee is considering a limit for this type of grasping current hazard of 100 mA. Measurements also indicated that electric field strengths in the general vicinity of the ship were on the order of 10 volts per meter. However, this is well within the ANSI C95.1 - 1982, Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 300 kHz to 100 GHz, limit of 632 volts per meter for AM radiofrequencies. Because of this induced current and an open circuit voltage from cable end to ground measured at approximately 300 volts by the Health Response Team, spark discharges occur just before and after grasping the cable. These discharges have resulted in burns.

Controls involve either isolating the crane hook from the crane cable and block assembly by an insulator or grounding the crane cable with a ground chain or wire. Either control has drawbacks. Insulators or insulated blocks are expensive and can affect the lift capability of a crane. Moreover, an isolated hook cannot prevent inadvertent employee contact with the crane cable itself. A grounding chain would have to be located manually with each individual lift thereby inviting inadvertent contact. Failing these controls, personal protective equipment in the manner of rubber-insert leather gloves, long sleeve shirts, safety helmets and safety glasses should be employed.

Please distribute this bulletin to all Area Offices, State Plan States and Consultation Projects.

Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.