Lujan Neutron Scattering Center at LANSCE

Ancillary Equipment


 

Low Temperature

Equipment


Specifications


Flight Path/Instrument Compatibility


Instrument Scientist


Displex closed-cycle refrigerators
T= 8 K to 340 K
11 – Asterix
04 – HIPPO
10 – LQD
02 – SMARTS
Victor Fanelli
vfanelli@lanl.gov

Or particular instrument scientist
Top loading closed-cycle refrigerator
T = 10 K to 500 K
option of in situ gas adsorption cell
07 – FDS
Luke Daemon
lld@lanl.gov

Monika Hartl
hartl@lanl.gov
Top Loading closed-cycle refrigerator
T = 15 K to 550 K
01 – NPDF
Katharine Page
kpage@lanl.gov
Top Loading closed-cycle refrigerator
T= 25 K to 600 K
optional rotating sample stick for texture
04 – HIPPO
Sven Vogel
sven@lanl.gov
ILL Orange Cryostats
T= 1.5 K to 300 K, 50 or 70 mm bore
11 – Asterix
10 – LQD
01 – NPDF
15 - PCS
02 – SMARTS
Victor Fanelli
vfanelli@lanl.gov
Liquid Nitrogen flow
T = 100 K
15 - PCS
Zoe Fisher
zfisher@lanl.gov

 

High Temperature

Equipment


Specifications


Flight Path/Instrument Compatibility


Instrument Scientist


Induction Heater
300 K to 1000 K
02 – SMARTS
Don Brown
dbrown@lanl.gov
High Temperature Vacuum Furnace
300 K to 2100 K
02 – SMARTS
Don Brown
dbrown@lanl.gov
High Temperature Vacuum Furnace with Load Frame
300 K to 1773 K
with 10 kN and 250 kN load cells
02 – SMARTS
Don Brown
dbrown@lanl.gov
High Temperature Furnace
Tmax = 2723 K
optional rotating sample stick for texture
04 – HIPPO
Sven Vogel
sven@lanl.gov
Matt Reiche
reiche@lanl.gov
High Temperature Furnace with Creep Rig
Tmax = 1273 K
max load = 2.7 kN
optional rotating sample stick for texture
04 – HIPPO
Sven Vogel
sven@lanl.gov
Matt Reiche
reiche@lanl.gov
ILL furnace
(Vanadium heating element)
Tmax = 1373 K
optional rotating sample stick for texture
04 – HIPPO
Sven Vogel
sven@lanl.gov
ILL furnace
(with controlled atmosphere)
Tmax = 1000 K
04 – HIPPO
Sven Vogel
sven@lanl.gov
Quenching furnace
Tmax = 1473 K
controlled atmosphere quench rate 20 K/sec
04 – HIPPO
02 – SMARTS
Don Brown
dbrown@lanl.gov
Cryofurnace
Tmax = 600 K
fits most closed-cycle refrigerator displexes
11 – Asterix
10 – LQD
01 – NPDF
15 - PCS
02 – SMARTS
Victor Fanelli
vfanelli@lanl.gov
Single sample heating stage
Tmax = 473 K
10 – LQD
Rex Hjelm
hjelm@lanl.gov

 

High Pressure

Equipment


Specifications


Flight Path/Instrument Compatibility


Instrument Scientist


Vanadium gas cell
0 to 200 bar
15 to 300 K
04 – HIPPO
Hong Xu
hxu@lanl.gov
Vanadium gas cell
300 K to 2100 K
01 – NPDF
Katharine Page
kpage@lanl.gov
Al gas pressure cell
0 to 6 kbar
10 K to 300 K
04 – HIPPO
Hong Xu
hxu@lanl.gov
Al gas pressure cell
0 to 8 kbar
10 K to 300 K
07 – FDS
Luke Daemon
lld@lanl.gov

Monika Hartl
hartl@lanl.gov
CuBe gas pressure cell
0 to 8 kbar
10 K to 300 K
04 – HIPPO
Hong Xu
hxu@lanl.gov
LQD Pressure cell
0 to 3 kbar
10 – LQD
Rex Hjelm
hjelm@lanl.gov
ZAP pressure cell
0 to 10 Gpa
04 – HIPPO
Jiangzhong Zhang
jzhang@lanl.gov
TAP-98
(High-pressure anvil cell)
10 GPa at ambient temperature and 1800 K
04 – HIPPO
Jiangzhong Zhang
jzhang@lanl.gov

 

Magnetic Fields

Equipment


Specifications


Flight Path/Instrument Compatibility


Instrument Scientist


11 T Cryomagnet
max field = 11 T
VTI option: T= 1.6 K to 300 K
3He insert: T = 0.3 K to 80 K
11 – Asterix
Michael Fitzsimmons
fitz@lanl.gov
XYZ Cryomagnet
max. field (horiz) = 2T
T=1.7K to 300K
11 – Asterix
Michael Fitzsimmons
fitz@lanl.gov
1.2T Electromagnet
T = 4 K to 300 K
11 – Asterix
Michael Fitzsimmons
fitz@lanl.gov
1.8T Electromagnet
max field = 1.5 T
T = 20 K to 300 K
optional rotation for texture
04 – HIPPO
02 – SMARTS
Don Brown
dbrown@lanl.gov

 

Specialized Equpment

Equipment


Specifications


Flight Path/Instrument Compatibility


Instrument Scientist


Automated gas-dosing manifold for in situ adsorption
 
All
Monika Hartl
hartl@lanl.gov
SMARTS Load frame
0 to 250 kN
02 – SMARTS
Don Brown
dbrown@lanl.gov
1.8T Electromagnet and load frame
max field = 1.5 T
max load =10 kN
02 – SMARTS
Don Brown
dbrown@lanl.gov
CRATES HIPPO Load frame
0 to 100 kN
04 – HIPPO
Sven Vogel
sven@lanl.gov
Stroboscopic Rheometer
Steady state shear up to 200 Nm torque
10 – LQD
09 – SPEAR
Rex Hjelm
hjelm@lanl.gov
Humidity cell
T = 300 K to 500 K
10 – LQD
Rex Hjelm
hjelm@lanl.gov
Circulating water/oil bath
water bath: 5 to 80°C
oil bath: T = ambient to 200°C
10 – LQD
Rex Hjelm
hjelm@lanl.gov
Langmuir Trough
Surface pressure and subphase temperature control.
Different size options.
09 – SPEAR
Jarek Majewski
jarek@lanl.gov
Solid-liquid Interface Cell
2" (51 mm)
3" (75 mm)
With liquid flow option
09 – SPEAR
Jarek Majewski
jarek@lanl.gov
Solid-liquid Interface Cell
High pressure (200 MPa)/high Temperature (300°C) neutron reflectivity measurements
09 – SPEAR
Jarek Majewski
jarek@lanl.gov
Electrochemical Cell
(In situ study of solid/liquid interface)
 
09 – SPEAR
Jarek Majewski
jarek@lanl.gov
Electrical conductivity cell
T =10 K to 400 K
07 – FDS
Luke Daemon
lld@lanl.gov

Monika Hartl
hartl@lanl.gov
Catalysis reactor/flow cell
In-situ catalysis
07 – FDS
Luke Daemon
lld@lanl.gov

Monika Hartl
hartl@lanl.gov
Robotic arm sample changer
 
04 – HIPPO
Sven Vogel
sven@lanl.gov
Matt Reiche
reiche@lanl.gov
Sample changer
 
04 – HIPPO
Sven Vogel
sven@lanl.gov
Matt Reiche
reiche@lanl.gov
Sample changer
 
10 – LQD
Rex Hjelm
hjelm@lanl.gov

 

User provided sample envrionments are with all instruments. Contact the instrument scientist.