Field
|
Data Type
|
Description
|
PointID
|
Text
|
Index Field.
|
Depth
|
Double
|
(ft) Index Field.
|
Imported Depth
|
Double
|
(ft) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
fs
|
Double
|
(tsf)
|
qc
|
Double
|
(tsf)
|
qt
|
Double
|
(tsf)
|
u2
|
Double
|
(tsf)
|
fs User Units
|
Double
|
(tsf) fs
|
qc User Units
|
Double
|
(tsf) qc
|
qt User Units
|
Double
|
(tsf) qt
|
u2 User Units
|
Double
|
(tsf) u2
|
u0
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Total Stress
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Effective Stress
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
FR
|
Double
|
(%) Friction Ratio Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
FR Normalized
|
Double
|
(%) Friction Ratio Normalized Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Bq
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Qt Normalized
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT Bq Normalized
|
Integer
|
Normalized Soil Behavior Type Bq Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT Fr Normalized
|
Integer
|
Normalized Soil Behavior Type Bq Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT Bq
|
Text
|
Soil Behavior Type Bq Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT Fr
|
Text
|
Soil Behavior Type Fr Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Estimated Total Density
|
Double
|
(pcf)This value is estimated based on the Soil Behavior Type Zone specified in the project table. It uses the values stored in the CPT Total Density table to determine what this value should be.
|
Ic
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
ED
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
ID
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
KD
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
OCR (1)
|
Double
|
Mayne (1995) - Reference #8. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
OCR (2)
|
Double
|
Chen & Mayne (1996) - Reference #9.Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
OCR (3)
|
Double
|
Chen & Mayne (1996) - Reference #9. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Ko (1)
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Ko (2)
|
Double
|
Chen & Mayne (1996) - Reference #9. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Equivalent N60
|
Double
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Equivalent N160
|
Double
|
Equivalent N Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Phi (1)
|
Single
|
Phi’ (1) Kulhawy & Mayne (1990) - Reference #1. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Phi (2)
|
Single
|
Phi' (2) Robertson & Campanella (1983) - Reference #13. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Phi (3)
|
Single
|
Phi' (3) Masood & Mitchell (1993) - Reference #14. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Su (1)
|
Single
|
(tsf) Mayne & Holtz (1988) - Reference #10. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Su (2)
|
Single
|
(tsf) Aas, Lacasse, Lunne, & Hoeg (1986) - Reference #11. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Su (3)
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Su (4)
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Su (5)
|
Double
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Dr (1)
|
Single
|
Kulhawy, F. H., and Mayne, P. W., (1990) - Reference #1. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Dr (2)
|
Single
|
Jamiolkowski et al (1985) - Reference # 18. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Dr (3)
|
Single
|
Baldi, Bellottie, Ghionna, Jamiolkowski, Pasqaulini (1986) - Reference #3. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
eo
|
Single
|
Kulhawy & Mayne (1990) - Reference #1. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
M (1)
|
Single
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
M (2)
|
Single
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
M (3)
|
Single
|
(tsf) Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
St (1)
|
Single
|
Lunne et al. - Reference #2. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
St (2)
|
Single
|
Lunne et al. - Reference #2. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Fines Content (1)
|
Single
|
Syms (2001) - Reference #4. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Fines Content (2)
|
Single
|
Syms (2001) - Reference #4. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
Total Density Override
|
Double
|
(pfc) Use this if you need to override the default density for the soil profile. This density is used only for the depth record that is input.
|
SBT FR Normalized Average 1
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Normalized Average 2
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Normalized Average 3
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Normalized Average Reported
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Average Reported
|
Long
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Average 1
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Average 2
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT FR Average 3
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Normalized Average 1
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Normalized Average 2
|
Long
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Normalized Average 3
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Average 1
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Average 2
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Average 3
|
Long
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Normalized Average Reported
|
Integer
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT BQ Average Reported
|
Long
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
SBT Gap
|
Boolean
|
Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
FR Averaged
|
Double
|
(%) Friction Ratio Averaged This is calculated as the fs/moving average of qt. Where the moving average of qt is based the average qt value over the interval specified in the CPT.FR Moving Average field. Calculated fields are Read-only in Input. Data can only be inserted by import or a gINT Rules procedure.
|
NkT Upper Bound Override
|
Single
|
|
NkT Lower Bound Override
|
Single
|
|