Skip to main content

Manchasol-2

This page provides information on Manchasol-2, a concentrating solar power (CSP) project, with data organized by background, participants, and power plant configuration.

Status Date: August 14, 2012
Project Overview
Project Name: Manchasol-2 (MS-2)
Country: Spain
Location: Alcazar de San Juan
(Ciudad Real)
Owner(s): ACS/Cobra Group (100%)
Technology: Parabolic trough
Turbine Capacity: Net: 50.0 MW Gross: 50.0 MW
Status: Operational
Start Year: 2011

Do you have more information, corrections, or comments?

Background

Technology: Parabolic trough
Status: Operational
Country: Spain
City: Alcazar de San Juan
Region: Ciudad Real
Lat/Long Location: 39°10′ 55.5″ North, 3°18′ 48.96″ West
Land Area: 200 hectares
Solar Resource: 2,208 kWh/m2/yr
Source of Solar Resource: Meteo Station
Electricity Generation: 158,000 MWh/yr (Expected/Planned)
Contact(s): Manuel Cortes; Gonzalo Puerto
Company: ACS/Cobra Group
Break Ground: May 2009
Start Production: April 2011
Construction Job-Years: 600
Annual O&M Jobs: 40
PPA/Tariff Rate: 27.0 Euro cents per kWh
PPA/Tariff Period: 25 years
Project Type: Commercial

Participants

Developer(s): ACS/Cobra Group
Owner(s) (%): ACS/Cobra Group (100%)
EPC Contractor: Cobra Instalaciones y Servicios
Operator(s): Cobra O&M
Generation Offtaker(s): Unión Fenosa

Plant Configuration

Solar Field

Solar-Field Aperture Area: 510,120 m²
# of Solar Collector Assemblies (SCAs): 624
# of Loops: 156
# of SCAs per Loop: 4
SCA Aperture Area: 817 m²
SCA Length: 144 m
# of Modules per SCA: 12
SCA Manufacturer (Model): Cobra Instalaciones y Servicios (Senertrough)
Mirror Manufacturer (Model): Flabeg (RP3)
# of Heat Collector Elements (HCEs): 11,232
HCE Manufacturer: Schott
# of HCEs: 11,232
HCE Manufacturer: Solel
Heat-Transfer Fluid Type: Diphenyl/Diphenyl oxide
Solar-Field Inlet Temp: 293°C
Solar-Field Outlet Temp: 393°C
Solar-Field Temp Difference: 100°C

Power Block

Turbine Capacity (Gross): 50.0 MW
Turbine Capacity (Net): 50.0 MW
Turbine Manufacturer: Siemens (Germany)
Power Cycle Pressure: 100.0 bar
Cooling Method: Wet cooling
Cooling Method Description: Cooling towers
Turbine Efficiency: 38.1% @ full load
Annual Solar-to-Electricity Efficiency (Gross): 16%
Fossil Backup Type: HTF heater
Backup Percentage: 12%

Thermal Storage

Storage Type: 2-tank indirect
Storage Capacity: 7.5 hour(s)
Thermal Storage Description: 28,500 tons of molten salt. 60% sodium nitrate, 40% potassium nitrate. 375 MWh. Tanks are 14 m high and 36 m in diameter.