FavoritePlease sign in to add this to your favorites. Topic: Exhaust Subtopic: Fans Desired Outcome: Provide primary ventilation for common spaces Manufactured HousingPrintCopy to ExcelEmail TitleSpecification(s)Objective(s) 6.6003.6a Clearance Clearance for size of the fan recommended will be determinedConsideration will be given for adequate head clearance Ensure access for installation, operation, and maintenanceEnsure occupant safety 6.6003.6b Power source Power source load will be determined as adequateConsideration will be given to power source location Provide accessible and adequate power source 6.6003.6c Location No resistance greater than 3 pascals will exist between fan intake location with reference to the common area Allow fresh air distribution to common areas 6.6003.6d Duct/vent Consideration will be given to: Vent termination location Amount of space for duct run Roof condition and type (e.g., metal, shingle, bow string, flat) Duct insulationWhen applicable, pitch duct to remove condensation to outdoorsDucts will be as straight as possible, fully extended, and have the shortest run possibleTo the extent possible, turns will be made so that the radius at the centerline is no less than one duct diameterDuct diameter will be equal to or greater than the exhaust fan outletFan flow will be verified by flow measurement to meet ASHRAE ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, www.ashrae.org standard 62.2 Effectively move the required volume of air 6.6003.6e Attachment Fan will be secured to a structural componentStructural integrity of the manufactured home will be maintained (e.g., roof trusses, walls, floor joists) Maintain structural integrityMaintain fan attachment 6.6003.6f Total exhaust airflow Total exhaust system airflow will be measured Ensure exhaust airflow is as designed Previous Detail Back to 6.6003 Fans Back to Top