5.3202.1 Reflective Coatings on Metal Roofs

Topic: 
Shading
Subtopic: 
Reflective Roofs
Desired Outcome: 
Reduce solar heat gain for manufactured homes
TitleSpecification(s)Objective(s)
5.3202.1a
Assessment

Existing roof coating will be assessed for hazardous material

Ensure worker and occupant safety

5.3202.1b
Preparation

Roof will be stripped of all debris, algae, and peeled and loose coating

Repairs to roof and penetrations will be made before application

Ensure roof is clean, dry, and structurally sound for proper adhesion of new coating

5.3202.1c
Materials selection

Material will be approved for application to metal and existing roof coating

Material will be an ENERGY STAR qualified reflective coating

Roof coating will be durable, flexible, reflective, and meet ASTM ASTM ASTM International, www.astm.org D412, ASTM ASTM ASTM International, www.astm.org D1737, and UL UL Underwriters Laboratories 790 Class A

Provide proper reflective coating

5.3202.1d
Application

Roof-coating material will be applied in accordance with manufacturer specifications

Ensure proper application

5.3202.1e
Occupant education

Occupant will be educated on the maintenance of reflective coating per manufacturer specifications, including annual inspection and cleaning

Preserve integrity and effectiveness of reflective coating