FLH Standard Drawings

FLH Standard Drawings are intended to cover various design elements and be applicable nationwide.  Each standard drawing is available in both Metric and US Customary units and conforms with the Standard Specifications (FP).  See the Acrobat Icon Revision Log  (Acrobat, 111 KB) for description of most recent approved changes.  If you have any questions or comments concerning these standard drawings please contact the Project Development Team.

The drawings are available in Acrobat (PDF) and MicroStation (DGN) formats.  Individual PDF files are available for both US Customary and Metric units.  The single DGN file contains both US Customary and Metric Standard Drawings.  Obtain the desired units by selecting either the 'USC' (US Customary) or 'Metric' View or Model (from the menu File -> Models).

Note:  Some older drawings contain sheet borders for each FLH division.  These will be phased out in preference to a standardized sheet.
Select desired DGN and/or PDF files using the check boxes below.  Use the button to create a ZIP.  Reload page to clear boxes.
157 - Soil Erosion and Sediment Control ApprRev
Acrobat Icon View Section 157 standards  (Acrobat, 4.08 MB)
(M)157-1; Silt Fence
Note: Temporarily withdrawn; see Division Details
 DGN Icon Temporary Inlet Protection  (DGN, 169 KB)
 Acrobat Icon 157-2  (Acrobat, 599 KB)
 Acrobat Icon M157-2  (Acrobat, 611 KB)
Note: Pending FLH approval 6/20053/2014
 DGN Icon Straw Bales  (DGN, 232 KB)
 Acrobat Icon 157-3  (Acrobat, 410 KB)
 Acrobat Icon M157-3  (Acrobat, 417 KB)
  6/2007-
 DGN Icon Sediment Trap  (DGN, 187 KB)
 Acrobat Icon 157-4  (Acrobat, 434 KB)
 Acrobat Icon M157-4  (Acrobat, 445 KB)
  6/2005-
 DGN Icon Temporary Diversion Channels  (DGN, 132 KB)
 Acrobat Icon 157-5  (Acrobat, 400 KB)
 Acrobat Icon M157-5  (Acrobat, 411 KB)
Note: Pending FLH approval 6/20073/2014
 DGN Icon Check Dam  (DGN, 114 KB)
 Acrobat Icon 157-6  (Acrobat, 242 KB)
 Acrobat Icon M157-6  (Acrobat, 249 KB)
  6/2007-
 DGN Icon Temporary Erosion Control Berms, Slope Drains, and Lined Waterways  (DGN, 120 KB)
 Acrobat Icon 157-7  (Acrobat, 513 KB)
 Acrobat Icon M157-7  (Acrobat, 525 KB)
  6/2005-
Top Next
501 - Minor Concrete Pavement ApprRev
Acrobat Icon View Section 501 standards  (Acrobat, 1.29 MB)
 DGN Icon Minor Concrete Pavement  (DGN, 97 KB)New
 Acrobat Icon 501-1  (Acrobat, 269 KB)
 Acrobat Icon M501-1  (Acrobat, 281 KB)
Note: Pending FLH approval -
5/1997
9/2016
 DGN Icon Minor Concrete Pavement Joints  (DGN, 124 KB)New
 Acrobat Icon 501-2  (Acrobat, 538 KB)
 Acrobat Icon M501-2  (Acrobat, 550 KB)
Note: Pending FLH approval -
6/1997
9/2016
Previous Top Next
502 - Concrete Pavement Restoration ApprRev
Acrobat Icon View Section 502 standards  (Acrobat, 628 KB)
 DGN Icon Concrete Pavement Restoration  (DGN, 119 KB)New
 Acrobat Icon 502-1  (Acrobat, 355 KB)
 Acrobat Icon M502-1  (Acrobat, 365 KB)
Note: Pending FLH approval -
3/1996
8/2016
Previous Top Next
556 - Bridge Railing ApprRev
Acrobat Icon View Section 556 standards  (Acrobat, 1.28 MB)
 DGN Icon Tubular Steel-backed Timber Bridge Rail  (DGN, 209 KB)
 Acrobat Icon 556-1  (Acrobat, 696 KB)
 Acrobat Icon M556-1  (Acrobat, 705 KB)
Note: 2 Sheets. Pending FLH approval -4/2014
Previous Top Next
601 - Minor Concrete Structures ApprRev
Acrobat Icon View Section 601 standards  (Acrobat, 7.19 MB)
 DGN Icon Concrete Headwalls  (DGN, 167 KB)
 Acrobat Icon 601-1  (Acrobat, 846 KB)
 Acrobat Icon M601-1  (Acrobat, 792 KB)
  6/2007
6/2005
-
 DGN Icon Slope Paving for Concrete Headwalls  (DGN, 162 KB)
 Acrobat Icon 601-2  (Acrobat, 819 KB)
 Acrobat Icon M601-2  (Acrobat, 769 KB)
  6/2005-
 DGN Icon Wingwalls for Concrete Headwalls  (DGN, 133 KB)
 Acrobat Icon 601-3  (Acrobat, 549 KB)
 Acrobat Icon M601-3  (Acrobat, 551 KB)
  6/2007-
 DGN Icon Concrete Headwall for Small Pipe Culvert  (DGN, 126 KB)
 Acrobat Icon 601-4  (Acrobat, 345 KB)
 Acrobat Icon M601-4  (Acrobat, 355 KB)
Note: Pending FLH approval 6/20053/2016
 DGN Icon Concrete Headwall/Wingwall for Single Normal 42" [1050] to 84" [2100] Pipe Culvert  (DGN, 151 KB)
 Acrobat Icon 601-5  (Acrobat, 610 KB)
 Acrobat Icon M601-5  (Acrobat, 632 KB)
  6/2005-
 DGN Icon Concrete Headwall/Wingwall for Single Skew 42" [1050] to 84" [2100] Pipe Culvert  (DGN, 133 KB)
 Acrobat Icon 601-6  (Acrobat, 444 KB)
 Acrobat Icon M601-6  (Acrobat, 455 KB)
  6/2005-
 DGN Icon Concrete Headwall/Wingwall for Multiple Normal 42" [1050] to 84" [2100] Pipe Culvert  (DGN, 118 KB)
 Acrobat Icon 601-7  (Acrobat, 333 KB)
 Acrobat Icon M601-7  (Acrobat, 354 KB)
  6/2005-
 DGN Icon Concrete Headwall/Wingwall for Multiple Skew 42" [1050] to 84" [2100] Pipe Culvert  (DGN, 134 KB)
 Acrobat Icon 601-8  (Acrobat, 469 KB)
 Acrobat Icon M601-8  (Acrobat, 483 KB)
  6/2005-
Previous Top Next
602 - Culverts and Drains ApprRev
Acrobat Icon View Section 602 standards  (Acrobat, 7.69 MB)
 DGN Icon Metal Pipe Culvert  (DGN, 138 KB)
 Acrobat Icon 602-1  (Acrobat, 645 KB)
 Acrobat Icon M602-1  (Acrobat, 650 KB)
  6/2005-
 DGN Icon Metal Pipe Culvert Coupling Band  (DGN, 176 KB)
 Acrobat Icon 602-2  (Acrobat, 613 KB)
 Acrobat Icon M602-2  (Acrobat, 633 KB)
  6/2005-
 DGN Icon Metal and Plastic Pipe Culvert Bedding  (DGN, 154 KB)
 Acrobat Icon 602-3  (Acrobat, 580 KB)
 Acrobat Icon M602-3  (Acrobat, 602 KB)
Note: Draft under review 6/200510/2014
 DGN Icon Metal End Sections  (DGN, 157 KB)
 Acrobat Icon 602-4  (Acrobat, 658 KB)
 Acrobat Icon M602-4  (Acrobat, 672 KB)
Note: Pending FLH approval 6/200510/2007
 DGN Icon Plastic Pipe Culvert  (DGN, 109 KB)
 Acrobat Icon 602-5  (Acrobat, 372 KB)
 Acrobat Icon M602-5  (Acrobat, 375 KB)
Note: Pending FLH approval 6/20052/2009
 DGN Icon Pipe Culvert Inlet Treatment in Cut Slopes  (DGN, 123 KB)
 Acrobat Icon 602-6  (Acrobat, 352 KB)
 Acrobat Icon M602-6  (Acrobat, 360 KB)
  6/2005-
 DGN Icon Concrete Pipe Culvert Installation  (DGN, 131 KB)
 Acrobat Icon 602-7  (Acrobat, 582 KB)
 Acrobat Icon M602-7  (Acrobat, 590 KB)
Note: Pending FLH approval 6/20056/2008
 DGN Icon Concrete End Section for Round Pipe  (DGN, 111 KB)
 Acrobat Icon 602-8  (Acrobat, 247 KB)
 Acrobat Icon M602-8  (Acrobat, 269 KB)
  6/2005-
 DGN Icon Metal End Sections with Safety Bars  (DGN, 184 KB)
 Acrobat Icon 602-9  (Acrobat, 638 KB)
 Acrobat Icon M602-9  (Acrobat, 645 KB)
Note: Pending FLH approval 6/20051/2016
Previous Top Next
603 - Structural Plate Structures ApprRev
Acrobat Icon View Section 603 standards  (Acrobat, 1.74 MB)
 DGN Icon Structural Plate Pipe Culvert  (DGN, 131 KB)
 Acrobat Icon 603-1  (Acrobat, 521 KB)
 Acrobat Icon M603-1  (Acrobat, 601 KB)
  6/2005-
 DGN Icon Structural Plate Pipe Arch Culvert  (DGN, 125 KB)
 Acrobat Icon 603-2  (Acrobat, 471 KB)
 Acrobat Icon M603-2  (Acrobat, 544 KB)
  6/2005-
Previous Top Next
604 - Manholes, Inlets, and Catch Basins ApprRev
Acrobat Icon View Section 604 standards  (Acrobat, 4.37 MB)
 DGN Icon Catch Basin, Type 1  (DGN, 108 KB)
 Acrobat Icon 604-1  (Acrobat, 281 KB)
 Acrobat Icon M604-1  (Acrobat, 293 KB)
  6/2005-
 DGN Icon Metal Frame and Grate, Type A  (DGN, 147 KB)
 Acrobat Icon 604-2  (Acrobat, 409 KB)
 Acrobat Icon M604-2  (Acrobat, 446 KB)
  6/2005-
 DGN Icon Metal Frame and Grate, Type B  (DGN, 150 KB)
 Acrobat Icon 604-3  (Acrobat, 408 KB)
 Acrobat Icon M604-3  (Acrobat, 437 KB)
  6/2007
6/2005
-
 DGN Icon Catch Basin, Type 2, with Down Drain  (DGN, 176 KB)
 Acrobat Icon 604-4  (Acrobat, 407 KB)
 Acrobat Icon M604-4  (Acrobat, 421 KB)
  6/2005-
 DGN Icon Inlet, Type 5A  (DGN, 150 KB)
 Acrobat Icon 604-5  (Acrobat, 266 KB)
 Acrobat Icon M604-5  (Acrobat, 279 KB)
  6/2005-
 DGN Icon Frame and Grate, Type 5A  (DGN, 125 KB)
 Acrobat Icon 604-6  (Acrobat, 265 KB)
 Acrobat Icon M604-6  (Acrobat, 287 KB)
  6/2005-
 DGN Icon Inlet, Type 6B  (DGN, 127 KB)
 Acrobat Icon 604-7  (Acrobat, 239 KB)
 Acrobat Icon M604-7  (Acrobat, 248 KB)
  6/2005-
 DGN Icon Inlet, Type 7A and 7B for 12" [300] to 36" [900] Culvert  (DGN, 141 KB)
 Acrobat Icon 604-8  (Acrobat, 430 KB)
 Acrobat Icon M604-8  (Acrobat, 451 KB)
  6/2007-
 DGN Icon Manhole  (DGN, 127 KB)
 Acrobat Icon 604-9  (Acrobat, 258 KB)
 Acrobat Icon M604-9  (Acrobat, 268 KB)
  6/2005-
Previous Top Next
606 - Corrugated Metal Spillways ApprRev
Acrobat Icon View Section 606 standards  (Acrobat, 1.16 MB)
 DGN Icon Slotted Drain Spillway Assembly  (DGN, 195 KB)
 Acrobat Icon 606-1  (Acrobat, 623 KB)
 Acrobat Icon M606-1  (Acrobat, 656 KB)
Note: Pending FLH approval 6/20053/2014
Previous Top Next
615 - Sidewalks, Pads, and Paved Medians ApprRev
Acrobat Icon View Section 615 standards  (Acrobat, 1.09 MB)
 DGN Icon Wheelchair Ramp Curb Cut  (DGN, 112 KB)
 Acrobat Icon 615-1  (Acrobat, 326 KB)
 Acrobat Icon M615-1  (Acrobat, 330 KB)
Note: New standard -1/2004
 DGN Icon Wheelchair Ramp Curb Taper  (DGN, 155 KB)
 Acrobat Icon 615-2  (Acrobat, 235 KB)
 Acrobat Icon M615-2  (Acrobat, 239 KB)
Note: New standard -1/2004
Previous Top Next
617 - Guardrail ApprRev
Acrobat Icon View general guardrail standards  (Acrobat, 9.82 MB); Std (M)617-10 to 24
 DGN Icon G4 W-Beam Guardrail, Wood Posts  (DGN, 167 KB)
 Acrobat Icon 617-10  (Acrobat, 523 KB)
 Acrobat Icon M617-10  (Acrobat, 545 KB)
Note: Pending FLH approval 6/200510/2013
 DGN Icon G4 W-Beam Guardrail, Steel Posts  (DGN, 178 KB)
 Acrobat Icon 617-11  (Acrobat, 556 KB)
 Acrobat Icon M617-11  (Acrobat, 583 KB)
Note: Pending FLH approval 6/200510/2013
 DGN Icon G4 W-Beam Guardrail, Modified Eccentric Loader Terminal, Type MELT  (DGN, 240 KB)
 Acrobat Icon 617-12  (Acrobat, 761 KB)
 Acrobat Icon M617-12  (Acrobat, 795 KB)
Note: 2 sheets. Pending FLH approval 6/20054/2016
 DGN Icon G4 W-Beam Guardrail, Installation in Rock  (DGN, 110 KB)
 Acrobat Icon 617-13  (Acrobat, 378 KB)
 Acrobat Icon M617-13  (Acrobat, 392 KB)
Note: Pending FLH approval -6/2014
 DGN Icon G4-W Beam Guardrail, Low Speed Terminal Type LST, Wood Posts  (DGN, 130 KB)
 Acrobat Icon 617-14  (Acrobat, 441 KB)
 Acrobat Icon M617-14  (Acrobat, 450 KB)
Note: Pending FLH approval 6/200512/2014
 DGN Icon G4 W-Beam Guardrail, MELT, LST   CRT Anchorage Assembly Details  (DGN, 130 KB)
 Acrobat Icon 617-15  (Acrobat, 353 KB)
 Acrobat Icon M617-15  (Acrobat, 374 KB)
Note: Pending FLH approval 6/20055/2014
 DGN Icon G4 W-Beam Guardrail, Back Slope Anchor Terminal Type G4-BAT  (DGN, 190 KB)
 Acrobat Icon 617-17  (Acrobat, 707 KB)
 Acrobat Icon M617-17  (Acrobat, 727 KB)
Note: 2 sheets. Pending FLH approval 6/20055/2014
 DGN Icon G4 W-Beam Guardrail, Type Flared Terminal  (DGN, 132 KB)
 Acrobat Icon 617-19  (Acrobat, 455 KB)
 Acrobat Icon M617-19  (Acrobat, 462 KB)
Note: Pending FLH approval 6/20053/2016
 DGN Icon G4 W-Beam Guardrail, Type Tangent Terminal  (DGN, 101 KB)
 Acrobat Icon 617-20  (Acrobat, 305 KB)
 Acrobat Icon M617-20  (Acrobat, 312 KB)
Note: Pending FLH approval 6/20053/2016
 DGN Icon CRG W-Beam Guardrail, Wood Posts  (DGN, 143 KB)
 Acrobat Icon 617-21  (Acrobat, 484 KB)
 Acrobat Icon M617-21  (Acrobat, 514 KB)
Note: Pending FLH approval 6/20053/2016
 DGN Icon G4 W-Beam Guardrail, Cable Releasing Terminal Type CRT, Wood Posts  (DGN, 141 KB)
 Acrobat Icon 617-22  (Acrobat, 419 KB)
 Acrobat Icon M617-22  (Acrobat, 448 KB)
Note: Pending FLH approval 6/20059/2014
 DGN Icon G4 W-Beam Guardrail, Long-Span System, TL-2  (DGN, 142 KB)
 Acrobat Icon 617-24  (Acrobat, 572 KB)
 Acrobat Icon M617-24  (Acrobat, 588 KB)
Note: 2 sheets. Pending FLH approval 6/20059/2014
Acrobat Icon View guardrail connection standards  (Acrobat, 4.12 MB); Std (M)617-25 to 29
 DGN Icon G4 W-Beam Guardrail Connection to Structure Vertical Face Wood Posts  (DGN, 120 KB)
 Acrobat Icon 617-25  (Acrobat, 512 KB)
 Acrobat Icon M617-25  (Acrobat, 539 KB)
Note: Under review -
3/1996
9/2013
 DGN Icon G4 W-Beam Guardrail Connection to Structure Vertical Face Steel Posts  (DGN, 126 KB)
 Acrobat Icon 617-26  (Acrobat, 508 KB)
 Acrobat Icon M617-26  (Acrobat, 538 KB)
Note: Under review -
1/1998
9/2013
 DGN Icon G4 W-Beam Guardrail Connection to Structure Safety Shape Face Wood Posts  (DGN, 131 KB)
 Acrobat Icon 617-27  (Acrobat, 531 KB)
 Acrobat Icon M617-27  (Acrobat, 557 KB)
Note: Under review -
1/1998
9/2013
 DGN Icon G4 W-Beam Guardrail Connection to Structure Safety Shape Face Steel Posts  (DGN, 135 KB)
 Acrobat Icon 617-28  (Acrobat, 514 KB)
 Acrobat Icon M617-28  (Acrobat, 542 KB)
Note: Under review -
1/1998
9/2013
 DGN Icon G4 W-Beam Guardrail Connection to Structure Safety Shape Face Rubrail  (DGN, 108 KB)
 Acrobat Icon 617-29  (Acrobat, 382 KB)
 Acrobat Icon M617-29  (Acrobat, 396 KB)
Note: Under review -
1/1998
9/2013
Acrobat Icon View steel-backed rail standards  (Acrobat, 13.16 MB); Std (M)617-60 to 82
 DGN Icon Steel-backed Timber Guardrail Type A   Type B  (DGN, 109 KB)
 Acrobat Icon 617-60  (Acrobat, 441 KB)
 Acrobat Icon M617-60  (Acrobat, 473 KB)
  6/2005-
 DGN Icon Steel-backed Timber Guardrail Terminal Section Type SBT-FAT  (DGN, 117 KB)
 Acrobat Icon 617-61  (Acrobat, 472 KB)
 Acrobat Icon M617-61  (Acrobat, 493 KB)
Note: Under review 6/200512/2013
 DGN Icon Steel-backed Timber Guardrail Terminal Section Type SBT-BAT  (DGN, 107 KB)
 Acrobat Icon 617-62  (Acrobat, 386 KB)
 Acrobat Icon M617-62  (Acrobat, 403 KB)
  6/2005-
 DGN Icon Steel-backed Timber Guardrail Around Circular Curves 70' [22 m] Radius and Below  (DGN, 190 KB)
 Acrobat Icon 617-63  (Acrobat, 446 KB)
 Acrobat Icon M617-63  (Acrobat, 490 KB)
  6/2005-
 DGN Icon Steel-backed Timber Guardrail TL-2 Connection to Stone Masonry Guardwall  (DGN, 239 KB)
 Acrobat Icon 617-64  (Acrobat, 897 KB)
 Acrobat Icon M617-64  (Acrobat, 1.17 MB)
Note: Under review -1/2008
 DGN Icon Steel-backed Timber Guardrail TL-3 Connection to Stone Masonry Guardwall  (DGN, 167 KB)
 Acrobat Icon 617-65  (Acrobat, 745 KB)
 Acrobat Icon M617-65  (Acrobat, 774 KB)
Note: Under review -1/2008
 DGN Icon Steel-backed Timber Guardrail Connection to Curved Back Structure  (DGN, 223 KB)
 Acrobat Icon 617-66  (Acrobat, 948 KB)
 Acrobat Icon M617-66  (Acrobat, 0.99 MB)
Note: Draft. Formerly Std 617-65 and 66 4/1994
3/1996
1/2008
 DGN Icon Steel-backed Timber Guardrail Test Level 2 Transition to Straight or Curved End Structure  (DGN, 254 KB)
 Acrobat Icon 617-67  (Acrobat, 1.19 MB)
 Acrobat Icon M617-67  (Acrobat, 1.27 MB)
Note: New draft standard -3/2008
 DGN Icon Steel-backed Timber Guardrail Connection to Tubular Steel-backed Timber Bridge Rail  (DGN, 97 KB)
 Acrobat Icon 617-68  (Acrobat, 332 KB)
 Acrobat Icon M617-68  (Acrobat, 341 KB)
Note: New draft standard -12/2007
 DGN Icon Steel-backed Timber Guardrail, TL-2 End Terminal  (DGN, 165 KB)
 Acrobat Icon 617-69  (Acrobat, 419 KB)
 Acrobat Icon M617-69  (Acrobat, 438 KB)
Note: Under review -9/2011
 DGN Icon Steel-backed Timber Guardrail, Median, Type A  (DGN, 134 KB)
 Acrobat Icon 617-70  (Acrobat, 390 KB)
 Acrobat Icon M617-70  (Acrobat, 406 KB)
Note: New standard -3/2010
 DGN Icon Steel-backed Log Rail  (DGN, 115 KB)
 Acrobat Icon 617-80  (Acrobat, 318 KB)
 Acrobat Icon M617-80  (Acrobat, 349 KB)
Note: Under review 6/200511/2013
 DGN Icon Steel-backed Log Rail Blockout  (DGN, 84 KB)
 Acrobat Icon 617-81  (Acrobat, 340 KB)
 Acrobat Icon M617-81  (Acrobat, 351 KB)
Note: Under review 6/200511/2013
 DGN Icon Steel-backed Log Rail Terminal Section, Type SBL-FAT  (DGN, 106 KB)
 Acrobat Icon 617-82  (Acrobat, 373 KB)
 Acrobat Icon M617-82  (Acrobat, 396 KB)
Note: Revision awaiting Safety Team review 6/200511/2013
Previous Top Next
618 - Concrete Barriers and Precast Guardwalls ApprRev
Acrobat Icon View Section 618 standards  (Acrobat, 1.35 MB)
 DGN Icon Precast Concrete Guardwall, Type 1  (DGN, 174 KB)
 Acrobat Icon 618-2  (Acrobat, 425 KB)
 Acrobat Icon M618-2  (Acrobat, 440 KB)
  6/2005-
 DGN Icon Precast Concrete Guardwall, Type 1, Terminal Sections, Type A and B  (DGN, 169 KB)
 Acrobat Icon 618-3  (Acrobat, 425 KB)
 Acrobat Icon M618-3  (Acrobat, 440 KB)
  6/2005-
Previous Top Next
619 - Fence, Gates, Cattle Guards and Bollard Posts ApprRev
Acrobat Icon View Section 619 standards  (Acrobat, 3.82 MB)
 DGN Icon Cattle Guard  (DGN, 212 KB)New
 Acrobat Icon 619-1  (Acrobat, 801 KB)
 Acrobat Icon M619-1  (Acrobat, 824 KB)
Note: Pending FLH approval 6/200510/2016
 DGN Icon Cattle Guard  (DGN, 170 KB)
 Acrobat Icon 619-2  (Acrobat, 823 KB)
 Acrobat Icon M619-2  (Acrobat, 841 KB)
Note: Pending FLH approval 6/20055/2008
 DGN Icon Cattle Guard Precast Foundation  (DGN, 192 KB)New
 Acrobat Icon 619-3  (Acrobat, 567 KB)
 Acrobat Icon M619-3  (Acrobat, 591 KB)
Note: Pending FLH approval 6/200510/2016
Previous Top Next
620 - Stone Masonry ApprRev
Acrobat Icon View Section 620 standards  (Acrobat, 1.99 MB)
 DGN Icon Stone Masonry Guardwall (Single Face)  (DGN, 121 KB)
 Acrobat Icon 620-1  (Acrobat, 420 KB)
 Acrobat Icon M620-1  (Acrobat, 439 KB)
  6/2005-
 DGN Icon Stone Masonry Guardwall (Double Face)  (DGN, 115 KB)
 Acrobat Icon 620-2  (Acrobat, 373 KB)
 Acrobat Icon M620-2  (Acrobat, 385 KB)
  6/2005-
 DGN Icon Stone Masonry Guardwall, Terminal Sections Type SAT and Type BT  (DGN, 116 KB)
 Acrobat Icon 620-3  (Acrobat, 472 KB)
 Acrobat Icon M620-3  (Acrobat, 482 KB)
  6/2005-
Previous Top
635 - Temporary Traffic Control ApprRev
Acrobat Icon View Section 635 standards  (Acrobat, 9.85 MB)
 DGN Icon Advance Signing  (DGN, 116 KB)
 Acrobat Icon 635-1  (Acrobat, 608 KB)
 Acrobat Icon M635-1  (Acrobat, 616 KB)
Note: Pending FLH approval 6/20056/2014
 DGN Icon Temporary Pavement Markings  (DGN, 105 KB)New
 Acrobat Icon 635-2  (Acrobat, 352 KB)
 Acrobat Icon M635-2  (Acrobat, 368 KB)
Note: Pending FLH approval 6/20059/2016
 DGN Icon Delineation and Signing for Unmarked Pavements  (DGN, 98 KB)New
 Acrobat Icon 635-3  (Acrobat, 369 KB)
 Acrobat Icon M635-3  (Acrobat, 369 KB)
Note: Pending FLH approval 6/20059/2016
 DGN Icon Temporary Traffic Control for Diversion  (DGN, 112 KB)
 Acrobat Icon 635-4  (Acrobat, 465 KB)
 Acrobat Icon M635-4  (Acrobat, 496 KB)
Note: Pending FLH approval 6/20056/2015
 DGN Icon Road Closure Layout (with Flaggers)  (DGN, 104 KB)
 Acrobat Icon 635-5  (Acrobat, 365 KB)
 Acrobat Icon M635-5  (Acrobat, 394 KB)
Note: Pending FLH approval 6/20058/2013
 DGN Icon Single Lane Closure Layout (with Flaggers)  (DGN, 111 KB)
 Acrobat Icon 635-6  (Acrobat, 421 KB)
 Acrobat Icon M635-6  (Acrobat, 451 KB)
Note: Pending FLH approval 6/200510/2013
 DGN Icon Single Lane Closure Layout (with Yield Sign)  (DGN, 119 KB)
 Acrobat Icon 635-7  (Acrobat, 443 KB)
 Acrobat Icon M635-7  (Acrobat, 475 KB)
Note: Pending FLH approval 6/20056/2014
 DGN Icon Single Lane Closure Layout (with Stop Signs)  (DGN, 130 KB)
 Acrobat Icon 635-8  (Acrobat, 498 KB)
 Acrobat Icon M635-8  (Acrobat, 537 KB)
Note: Pending FLH approval 6/20058/2013
 DGN Icon Single Lane Closure Layout (with Signals)  (DGN, 122 KB)New
 Acrobat Icon 635-9  (Acrobat, 580 KB)
 Acrobat Icon M635-9  (Acrobat, 614 KB)
Note: Pending FLH approval 6/20059/2016
 DGN Icon Shoulder Closure Layout  (DGN, 109 KB)
 Acrobat Icon 635-10  (Acrobat, 418 KB)
 Acrobat Icon M635-10  (Acrobat, 432 KB)
Note: Pending FLH approval 6/20058/2013
 DGN Icon Part Lane Width and Shoulder Closure Layout  (DGN, 113 KB)
 Acrobat Icon 635-11  (Acrobat, 506 KB)
 Acrobat Icon M635-11  (Acrobat, 532 KB)
Note: Pending FLH approval 6/20058/2013
 DGN Icon Part Lane Width and Shoulder Closure Layout with Temporary Barrier  (DGN, 118 KB)
 Acrobat Icon 635-12  (Acrobat, 556 KB)
 Acrobat Icon M635-12  (Acrobat, 580 KB)
Note: Pending FLH approval 6/20056/2015
 DGN Icon Single Lane Closure Layout with Temporary Barrier  (DGN, 102 KB)
 Acrobat Icon 635-13  (Acrobat, 381 KB)
 Acrobat Icon M635-13  (Acrobat, 385 KB)
Note: Pending FLH approval 6/20056/2015
 DGN Icon Sign Installation, Wood Posts  (DGN, 110 KB)
 Acrobat Icon 635-14  (Acrobat, 378 KB)
 Acrobat Icon M635-14  (Acrobat, 399 KB)
Note: Pending FLH approval 6/20059/2014
Previous Top

Resources  |  Top