Click a state to see county-by-county climate zone information.

South Carolina Hawaii Hawaii Hawaii Hawaii Hawaii Hawaii Hawaii Alaska Alaska Alaska Alaska Alaska Alaska Alaska Alaska Alaska Alaska Florida Florida Florida Georgia Alabama North Carolina North Carolina Tennessee Rhode Island Connecticut Massachusetts Massachusetts Massachusetts Maine Maine Maine New Hampshire Vermont New York New Jersey Pennsylvania Delaware Maryland Maryland West Virginia Virginia Kentucky Ohio Michigan Michigan Michigan Michigan Wyoming Montana Idaho Washington Washington Texas Texas California California California California California Arizona Nevada Utah Colorado New Mexico Oregon Oregon North Dakota South Dakota Nebraska Iowa Mississippi Indiana Illinois Minnesota Wisconsin Missouri Arkansas Oklahoma Kansas Louisiana

Select a state and county to view its minimum insulation requirements.

Visit the Status of State Energy Codes website to see if your state has adopted the 2009 IECC.

Climate Zone 1

Ceiling R-value30
Wood Frame Wall R-value 13
Mass Wall R-value i 3/4
Floor R-value 13
Basement Wall R-value c 0
Slab R-value d, Depth 0
Crawlspace Wall R-value c 0
Fenestration U-Factor b 1.2
Skylight U-Factor b 0.75
Glazed fenestration SHGC b, e 0.30

Climate Zone 2

Ceiling R-value30
Wood Frame Wall R-value 13
Mass Wall R-value i 4/6
Floor R-value 13
Basement Wall R-value c 0
Slab R-value d, Depth 0
Crawlspace Wall R-value c 0
Fenestration U-Factor b 0.65j
Skylight U-Factor b 0.75
Glazed fenestration SHGC b, e 0.30

Climate Zone 3

Ceiling R-value30
Wood Frame Wall R-value 13
Mass Wall R-value i 5/8
Floor R-value 19
Basement Wall R-value c 5/13f
Slab R-value d, Depth 0
Crawlspace Wall R-value c 5/13
Fenestration U-Factor b 0.50j
Skylight U-Factor b 0.65
Glazed fenestration SHGC b, e 0.30

Climate Zone 4 (Except Marine)

Ceiling R-value38
Wood Frame Wall R-value 13
Mass Wall R-value i 5/10
Floor R-value 19
Basement Wall R-value c 10/13
Slab R-value d, Depth 10, 2 ft
Crawlspace Wall R-value c 10/13
Fenestration U-Factor b 0.35
Skylight U-Factor b 0.60
Glazed fenestration SHGC b, e NR

Climate Zone 5 & 4 Marine

Ceiling R-value38
Wood Frame Wall R-value 20 or 13+5h
Mass Wall R-value i 13/17
Floor R-value 30g
Basement Wall R-value c 10/13
Slab R-value d, Depth 10, 2 ft
Crawlspace Wall R-value c 10/13
Fenestration U-Factor b 0.35
Skylight U-Factor b 0.60
Glazed fenestration SHGC b, e NR

Climate Zone 6

Ceiling R-value49
Wood Frame Wall R-value 20 or 13+5h
Mass Wall R-value i 15/19
Floor R-value 30g
Basement Wall R-value c 15/19
Slab R-value d, Depth 10, 4 ft
Crawlspace Wall R-value c 10/13
Fenestration U-Factor b 0.35
Skylight U-Factor b 0.60
Glazed fenestration SHGC b, e NR

Climate Zone 7 & 8

Ceiling R-value49
Wood Frame Wall R-value 21
Mass Wall R-value i 19/21
Floor R-value 38g
Basement Wall R-value c 15/19
Slab R-value d, Depth 10, 4 ft
Crawlspace Wall R-value c 10/13
Fenestration U-Factor b 0.35
Skylight U-Factor b 0.60
Glazed fenestration SHGC b, e NR

a. R-values are minimums. U-factors and SHGC are maximums. R-19 batts compressed into a nominal 2x6 framing cavity such that the R-value is reduced by R-1 or more shall be marked with the compressed batt R-value in addition to the full thickness R-value.

b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.

c. "15/19" means R-15 continuous insulated sheathing on he interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. "10/13" means R-10 continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall.

d. R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in zones 1 through 3 for heated slabs.

e. There are no SHGC requirements in the Marine zone.

f. Basement Wall Insulation is not required in warm-humid locations.

g. Or insulation sufficient to fill the framing cavity. R-19 is minimum.

h. "13+5" means R-13 cavity insulation plus R-5 insulated sheathing. If structural sheathing covers 25 percnt or less of the exterior, insulating sheathing is not required where structural sheathing is used. If structural sheathing covers more than 25 percent of exteriror, structural sheathing shall be supplemented with insulated sheathing of atleast R-2.

i. The second R-value applies when more than half the insulation is on the interior of the wall.

j. For impact rated fenestration complying with SectionR301.2.1.2 of the International Residential Code or Section 1608.1.2 of the International Building code, the maximum U-factor shall be 0.75 in Zone 2 and 0.65 in Zone 3.