[Skip Sub Navigation]Building Systems Upgrades
The following are Sustainable Strategies to consider as your space undergoes a building system upgrade to improve energy, water use and occupant comfort. Refer to the Share Section for a representative project Case Study to discover key practices, benefits, results and checklists.
References/Resources:
- Federal Acquisition Regulation (FAR) Part 23: 23.703 Policy: Government policy on the acquisition of environmentally preferable, energy efficient, and water conserving products and services, including EPEAT-registered products
- LEED 2009 for Existing Building Operations & Maintenance Rating System
- California Commissioning Collaborative
- US Environmental Protection Agency I-Beam Forms
- Green Cleaning Network
- Green Seal
- Carpet and Rug Institute
Sustainable Strategies
Lighting and Lighting Controls
- Use Federal Acquisition Regulation (FAR) environmental and energy guidelines for product and service purchases
- Replace old fluorescent lighting with high-efficiency low-mercury T8 or T5 and compact fluorescent bulbs
- For highest performance, design a lighting scheme with daylight photo-sensors, dimming electronic ballasts, light shelves, occupancy sensors and automatic shades
- Use proper day lighting in a workplace to increase worker productivity and morale while reducing lighting and cooling energy costs
- Reroute direct sunlight with light shelf strategies to the ceiling and allow it to be diffused over a large area as a way to handle glare issues for workers
- Use dynamic systems such as automated shades to block, control, or filter sunlight to reduce or eliminate negative effects of glare and heat
- Use glazing on interior offices and shared spaces to maximize access to daylight and views from all locations and provide privacy with opaque glazing or applied polyester opaque film up to 48" height.
- Consider lowering the height of the workstation panels to approximately 48" in an open office environment allowing for views while still providing visual and acoustical privacy
- Use lighting fixtures that are either indirect, direct-indirect pendant lighting, or indirect lay-in fixtures to reduce glare and visual stress
- Choose lighting systems to accommodate both office and workstation arrangements without modification
- Enable occupant control of lighting levels with task lights or individual controls
- Consider using occupancy sensors to control dedicated power receptacles for task lighting in offices and workstations
- Provide feedback to occupants on energy use through the use of a dashboard or other display methods
HVAC & HVAC Controls
- Maintain acceptable temperature and relative humidity
- Enable occupant control of ambient conditions in their workspace through individual or zone control of ventilation and temperatures
- Educate occupants when new controls are provided
- Consider using wireless thermostats for VAV boxes allowing them to be easily relocated and managed remotely
- Provide feedback to occupants on energy use through the use of a dashboard or other display methods
- Retrofit existing cooling systems to run on environmentally friendly HFCs
Plumbing
- Use Federal Acquisition Regulation (FAR) environmental and energy guidelines for product and service purchases
- Use low flow aerators on lavatories (.5 gpm), low flow showerheads (2.5 gpm), and dual flush toilets (0.8/1.6 gpf) or low flow toilets (1.2 gpf)
- Consider waterless urinals to save significant amounts of water, and ensure that cleaning and maintenance staff receive training in the specific maintenance regimes and training required
- Install automatic fixture sensors on lavatories for water savings, but avoid automatic flushes on toilets because they often result in double flushing and are not recommended
- Consider high-efficiency water fountains, with a wider range of acceptable temperature to encourage use of tap over bottled water. Incorporate taps into the design to make them user friendly
Acoustic Systems
- Use Federal Acquisition Regulation (FAR) environmental and energy guidelines for product and service purchases
- Incorporate a blend of Design, treatments and behavioral programming to address acoustic issues systematically
- Improve acoustical quality through the minimization and isolation of noise levels and vibration relative to the space use to ensure speech intelligibility in conference rooms and speech privacy for offices
- Provide modular or removable panel extensions to workstations that can be used when more privacy is needed
- Insure the installation of sound-rated walls and insulation meets end user privacy requirements
- Install acoustical ceiling tiles with higher NRC absorption in the open office areas
- Implement sound control strategies and properly tuned sound masking systems
- Use carpet and sound absorbing materials to dampen sound
- Reinforce acoustically quiet areas with appropriate visual cues such as opaque walls or signage.
Help us improve the Sustainable Facilities Tool by taking a quick survey.
Did You Know?
![building dyk](https://webarchive.library.unt.edu/web/20130225132219im_/https://sftool.gov/Content/attachments/didyouknow.png)
Buildings are one of the heaviest consumers of natural resources and account for a significant portion of the greenhouse gas emissions that affect climate change. In the U.S., buildings account for 38% of all CO2 emissions.
Source: Energy Information Administration (2008). Assumptions to the Annual Energy Outlook.
Case Study
Comfort
![Operable Windows](https://webarchive.library.unt.edu/web/20130225132219im_/https://sftool.gov/Content/attachments/Comfort_Window.jpg)
Comfortable workers are more likely to be productive and engaged with their work than those who struggle to work in spaces that create barriers and stresses. With ever increasing needs to be mindful of the environment when designing spaces, GSA is developing practices that support both sustainability and worker comfort.