Hatch 2
2Q/2012 Performance Indicators
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 1.0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2065.1 | 1324.7 | 2208.0 | 1954.3 | 2183.0 | 2063.2 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0.9 | 0.9 | 0.8 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Unplanned power changes | 0 | 0 | 0 | 1.0 | 1.0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2065.1 | 1324.7 | 2208.0 | 1954.3 | 2183.0 | 2063.2 |
Indicator value | 0.8 | 0.8 | 0 | 0.9 | 1.8 | 1.9 | 1.8 | 0.8 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
Indicator value | 1 | 1 | 0 | 0 | 0 | 1 | 1 | 1 |
Licensee Comments:
4Q/11: LER 2011-001, Rev. 1
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | 1.32E-07 | 2.07E-07 | 2.22E-07 | 1.75E-07 | 1.61E-07 | 1.60E-07 | 1.69E-07 | 2.17E-07 |
URI (ΔCDF) | 5.79E-08 | 1.35E-07 | 1.30E-07 | 1.44E-07 | -5.97E-08 | -6.34E-08 | -4.61E-08 | -3.43E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.90E-07 | 3.40E-07 | 3.50E-07 | 3.20E-07 | 1.00E-07 | 9.60E-08 | 1.20E-07 | 1.80E-07 |
Licensee Comments:
1Q/11: Changed PRA Parameter(s). All PRA inputs were revised effective 4Q10 to reflect Rev 4 of the PRA model revised 3Q10. Version E of the Hatch MSPI Basis Document was approved on 12/28/2010.
4Q/10: Changed PRA Parameter(s). All PRA inputs were revised to reflect the Rev 4 PRA model (effective September 14, 2010), updated EDG mission time per Rev. 6 changes to NEI-99-02. These changes were incorporated into MSPI Basis Document, effective 12/28/2010.
3Q/10: Risk Cap Invoked.
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | -2.62E-08 | -1.46E-08 | -2.24E-08 | -2.24E-08 | -2.24E-08 | -2.24E-08 | -2.24E-08 | -2.24E-08 |
URI (ΔCDF) | 1.52E-07 | 9.27E-08 | -3.61E-08 | -3.51E-08 | -3.37E-08 | -3.49E-08 | -3.46E-08 | -3.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.30E-07 | 7.80E-08 | -5.80E-08 | -5.70E-08 | -5.60E-08 | -5.70E-08 | -5.70E-08 | -5.40E-08 |
Licensee Comments:
1Q/11: Changed PRA Parameter(s). All PRA inputs were revised effective 4Q10 to reflect Rev 4 of the PRA model revised 3Q10. Version E of the Hatch MSPI Basis Document was approved on 12/28/2010.
4Q/10: Changed PRA Parameter(s). All PRA inputs were revised to reflect the Rev 4 PRA model (effective September 14, 2010), updated EDG mission time per Rev. 6 changes to NEI-99-02. These changes were incorporated into MSPI Basis Document, effective 12/28/2010.
Mitigating Systems Performance Index, Heat Removal System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | 5.54E-09 | 1.01E-08 | 1.51E-08 | 1.61E-08 | 1.56E-08 | 1.60E-08 | 1.43E-08 | 1.27E-08 |
URI (ΔCDF) | -8.34E-08 | -1.88E-08 | -1.57E-08 | -1.63E-08 | -1.53E-08 | -1.53E-08 | -1.52E-08 | -1.40E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -7.80E-08 | -8.70E-09 | -6.30E-10 | -2.30E-10 | 3.30E-10 | 7.10E-10 | -9.00E-10 | -1.30E-09 |
Licensee Comments:
1Q/11: Changed PRA Parameter(s). All PRA inputs were revised effective 4Q10 to reflect Rev 4 of the PRA model revised 3Q10. Version E of the Hatch MSPI Basis Document was approved on 12/28/2010.
4Q/10: Changed PRA Parameter(s). All PRA inputs were revised to reflect the Rev 4 PRA model (effective September 14, 2010), updated EDG mission time per Rev. 6 changes to NEI-99-02. These changes were incorporated into MSPI Basis Document, effective 12/28/2010.
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | 3.29E-08 | 5.86E-08 | 6.81E-08 | 7.23E-08 | 2.03E-08 | 2.13E-08 | 1.69E-08 | 1.45E-08 |
URI (ΔCDF) | 2.82E-08 | 3.47E-08 | 4.73E-08 | 5.41E-08 | 6.51E-08 | 6.14E-08 | -1.16E-07 | -1.13E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 6.10E-08 | 9.30E-08 | 1.20E-07 | 1.30E-07 | 8.50E-08 | 8.30E-08 | -9.90E-08 | -9.90E-08 |
Licensee Comments:
1Q/11: Changed PRA Parameter(s). All PRA inputs were revised effective 4Q10 to reflect Rev 4 of the PRA model revised 3Q10. Version E of the Hatch MSPI Basis Document was approved on 12/28/2010.
4Q/10: Changed PRA Parameter(s). All PRA inputs were revised to reflect the Rev 4 PRA model (effective September 14, 2010), updated EDG mission time per Rev. 6 changes to NEI-99-02. These changes were incorporated into MSPI Basis Document, effective 12/28/2010.
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | 6.63E-08 | 1.40E-07 | 1.41E-07 | 7.78E-08 | 7.80E-08 | 5.26E-08 | 3.55E-08 | 5.68E-08 |
URI (ΔCDF) | 4.87E-08 | 1.32E-07 | 1.37E-07 | 8.92E-08 | 9.28E-08 | 5.08E-09 | 9.56E-09 | 1.08E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.20E-07 | 2.70E-07 | 2.80E-07 | 1.70E-07 | 1.70E-07 | 5.80E-08 | 4.50E-08 | 6.80E-08 |
Licensee Comments:
1Q/11: Changed PRA Parameter(s). All PRA inputs were revised effective 4Q10 to reflect Rev 4 of the PRA model revised 3Q10. Version E of the Hatch MSPI Basis Document was approved on 12/28/2010.
4Q/10: Changed PRA Parameter(s). All PRA inputs were revised to reflect the Rev 4 PRA model (effective September 14, 2010), updated EDG mission time per Rev. 6 changes to NEI-99-02. These changes were incorporated into MSPI Basis Document, effective 12/28/2010.
3Q/10: Changed PRA Parameter(s). Update for change file: Version D of the Basis Document shows that the FVUAP values for Unit 2 RHRSW divisions 1 and 2 should be 3.90e-02 and 7.22e-02, respectively. However, the January Unit 2 Cooling Water Derivation Report shows that the FVUAP values for U2 RHRSW divisions 1 and 2 are still Version C values. Since the values in Version E of the Basis Document went into effect October 2010, the FVUAP values were overridden from January 2009 through September 2010 for U2 RHRSW Divisions 1 and 2 to be 3.90e-02 and 7.22e-02, as described in Version D of the Basis. This change did not affect the ???color??? of the indicator.
Reactor Coolant System Activity | 7/10 | 8/10 | 9/10 | 10/10 | 11/10 | 12/10 | 1/11 | 2/11 | 3/11 | 4/11 | 5/11 | 6/11 |
Maximum activity | 0.000127 | 0.000143 | 0.000143 | 0.000136 | 0.000128 | 0.000126 | 0.000121 | 0.000115 | 0.000111 | N/A | 0.000045 | 0.000054 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | N/A | 0 | 0 |
Reactor Coolant System Activity | 7/11 | 8/11 | 9/11 | 10/11 | 11/11 | 12/11 | 1/12 | 2/12 | 3/12 | 4/12 | 5/12 | 6/12 |
Maximum activity | 0.000058 | 0.000060 | 0.000048 | 0.000038 | 0.000084 | 0.000048 | 0.000062 | 0.000064 | 0.000116 | 0.000063 | 0.000062 | 0.000062 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.1 | 0 | 0 | 0 |
Licensee Comments:
6/11: Unit 2 was in a refueling outage the month of April.
Reactor Coolant System Leakage | 7/10 | 8/10 | 9/10 | 10/10 | 11/10 | 12/10 | 1/11 | 2/11 | 3/11 | 4/11 | 5/11 | 6/11 |
Maximum leakage | 1.740 | 1.610 | 1.520 | 1.500 | 1.420 | 1.420 | 1.350 | 1.360 | 1.440 | N/A | 1.770 | 1.770 |
Technical specification limit | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 |
Indicator value | 5.8 | 5.4 | 5.1 | 5.0 | 4.7 | 4.7 | 4.5 | 4.5 | 4.8 | N/A | 5.9 | 5.9 |
Reactor Coolant System Leakage | 7/11 | 8/11 | 9/11 | 10/11 | 11/11 | 12/11 | 1/12 | 2/12 | 3/12 | 4/12 | 5/12 | 6/12 |
Maximum leakage | 1.790 | 1.770 | 1.790 | 1.690 | 1.730 | 1.730 | 1.710 | 1.650 | 1.620 | 1.670 | 1.750 | 1.710 |
Technical specification limit | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 |
Indicator value | 6.0 | 5.9 | 6.0 | 5.6 | 5.8 | 5.8 | 5.7 | 5.5 | 5.4 | 5.6 | 5.8 | 5.7 |
Licensee Comments:
6/11: Unit 2 was in a Refueling Outage during the month of April
Drill/Exercise Performance | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Successful opportunities | 38.0 | 8.0 | 6.0 | 30.0 | 27.0 | 20.0 | 10.0 | 70.0 |
Total opportunities | 40.0 | 8.0 | 6.0 | 32.0 | 27.0 | 21.0 | 10.0 | 72.0 |
Indicator value | 96.4% | 96.4% | 96.5% | 95.3% | 95.8% | 96.6% | 96.5% | 96.8% |
Licensee Comments:
3Q/11: During NRC EP Inspection, 10/31/11, did not have supporting documentation for drill DEP Opportunity, had to remove ERO participation credit for individuals involved and opportunities.
1Q/11: During NRC EP Inspections, 10/31/11, did not have supporting documentation for drill DEP Opportunity, had to remove ERO participation credit for individuals involved and opportunities.
ERO Drill Participation | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Participating Key personnel | 136.0 | 138.0 | 134.0 | 141.0 | 145.0 | 150.0 | 150.0 | 149.0 |
Total Key personnel | 136.0 | 138.0 | 134.0 | 143.0 | 145.0 | 150.0 | 150.0 | 149.0 |
Indicator value | 100.0% | 100.0% | 100.0% | 98.6% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments:
2Q/11: During NRC EP Inspection, 10/31/11, did not have supporting documentation for drill DEP Opportunity, had to remove ERO participation credit for individuals involved and Opportunities.
1Q/11: During NRC EP Inspectin, 10/31/11, did not have supporting doucmentation for drill DEP Opportunity, had to remove ERO participation credit for individuals involved and opportunities.
Alert & Notification System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Successful siren-tests | ||||||||
Total sirens-tests | ||||||||
Indicator value |
Licensee Comments:
2Q/12: Plant Hatch does not use sirens as an emergency notification system.
1Q/12: Plant Hatch does not use sirens as an emergency notifications system.
4Q/11: Plant Hatch does not use sirens as an emergency notification system.
3Q/11: Plant Hatch does not use sirens as an emergency notification system.
2Q/11: Plant Hatch does not use sirens as an emergency notification system.
1Q/11: Plant Hatch does not use sirens as an emergency notification system.
4Q/10: Plant Hatch does not use sirens as an emergency notificaton system.
3Q/10: Plant Hatch does not use sirens as an emergency notification system.
Occupational Exposure Control Effectiveness | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Although the Security Cornerstone is included in the Reactor Oversight Process assessment program, the Commission has decided that specific information related to findings and performance indicators pertaining to the Security Cornerstone will not be publicly available to ensure that security information is not provided to a possible adversary. Other than the fact that a finding or performance indicator is Green or Greater-Than-Green, security related information will not be displayed on the public web page.