What are the requirements for front end structures used as part of a cargo securement system?

Regulations current to Aug 30, 2012
         
Examples: Medical Form, 391.53, 391
 
Up All Regulations
Up Part 393
 
< 393.112 393.116 >
Subpart I - Protection against shifting and falling cargo

Code of Federal Regulationsยง 393.114What are the requirements for front end structures used as part of a cargo securement system? (a) Applicability. The rules in this section are applicable to commercial motor vehicles transporting articles of cargo that are in contact with the front end structure of the vehicle. The front end structure on these cargo-carrying vehicles must meet the performance requirements of this section.
Code of Federal Regulations464
(b) Height and width. (1) The front end structure must extend either to a height of 4 feet above the floor of the vehicle or to a height at which it blocks forward movement of any item or article of cargo being carried on the vehicle, whichever is lower. (2) The front end structure must have a width which is at least equal to the width of the vehicle or which blocks forward movement of any article of cargo being transported on the vehicle, whichever is narrower. (c) Strength. The front end structure must be capable of withstanding the following horizontal forward static load: (1) For a front end structure less than 6 feet in height, a horizontal forward static load equal to one-half (0.5) of the weight of the articles of cargo being transported on the vehicle uniformly distributed over the entire portion of the front end structure that is within 4 feet above the vehicle's floor or that is at or below a height above the vehicle's floor at which it blocks forward movement of any article of the vehicle's cargo, whichever is less; or(2) For a front end structure 6 feet in height or higher, a horizontal forward static load equal to four-tenths (0.4) of the weight of the articles of cargo being transported on the vehicle uniformly distributed over the entire front end structure. (d) Penetration resistance. The front end structure must be designed, constructed, and maintained so that it is capable of resisting penetration by any article of cargo that contacts it when the vehicle decelerates at a rate of 20 feet per second, per second. The front end structure must have no aperture large enough to permit any article of cargo in contact with the structure to pass through it. (e) Substitute devices. The requirements of this section may be met by the use of devices performing the same functions as a front end structure, if the devices are at least as strong as, and provide protection against shifting articles of cargo at least equal to, a front end structure which conforms to those requirements. [67 FR 61225, Sept. 27, 2002, as amended at 71 FR 35833, June 22, 2006]

 
 