Application of correction factors.

Regulations current to Aug 30, 2012
         
Examples: Medical Form, 391.53, 391
 
Up All Regulations
Up Part 325
 
< 325.77 325.91 >
Subpart F - Correction Factors

Code of Federal Regulations§ 325.79Application of correction factors.(a) If two correction factors apply to a measurement they are applied cumulatively.(b) The following examples illustrate the application of correction factors to sound level measurement readings: (1) Example 1—Highway operations. Assume that a motor vehicle generates a maximum observed sound level reading of 86 dB(A) during a measurement in accordance with the rules in subpart D of this part. Assume also that the distance between the microphone location point and the microphone target point is 60 feet (18.3 m) and that the measurement area of the test site is acoustically “hard.” The corrected sound level generated by the motor vehicle would be 85 dB(A), calculated as follows: 86 dB(A)Uncorrected reading+1 dB(A)Distance correction factor-2 dB(A)Ground surface correction factor_____ 85 dB(A)Corrected reading (2) Example 2—Stationary test. Assume that a motor vehicle generates maximum sound level readings which average 88 dB(A) during a measurement in accordance with the rules in subpart E of this part. Assume also that the distance between the microphone location point and the microphone target point is 35 feet (10.7 m), and that the measurement area of the test site is acoustically “soft.” The corrected sound level generated by the motor vehicle would be 87 dB(A), calculated as follows: 88 dB(A)Uncorrected average of readings-3 dB(A)Distance correction factor+2 dB(A)Ground surface correction factor_____ 87 dB(A)Corrected reading

 
 
Connect with us
FMCSA's Contact Us  FMCSA's Facebook page

Feedback | Privacy Policy | USA.gov | Freedom of Information Act (FOIA) | Accessibility | OIG Hotline | Web Policies and Important Links | Site Map | Plug-ins

Federal Motor Carrier Safety Administration
1200 New Jersey Avenue SE, Washington, DC 20590 • 1-800-832-5660 • TTY: 1-800-877-8339 • Field Office Contacts