High Pressure Test Facility for Metal Dusting Resistance:

The facility is used to evaluate the performance of Fe- and Ni-base structural alloys in metal dusting environments at temperatures up to 700°C and pressures up to 600 psi.

High Pressure Metal Dusting Test FacilityHigh Pressure Metal Dusting Test Facility: Structural materials are tested for their corrosion resistance in simulated metal dusting environments at elevated temperatures, typical of conditions in hydrogen-, ammonia-, and methanol-reformers and in syngas plants.
Click on photo to view a larger image.

Atmospheric Pressure Test Facility for Metal Dusting:

We have five facilities that are used to develop a mechanistic understanding of metal dusting degradation and to evaluate newly developed alloys, coatings, and weldments with improved metal dusting resistance.

Atmospheric tests facilitiesAtmospheric tests facilities are used to develop a fundamental understanding of metal dusting reactions and material performance over a wide range of simulated process conditions, temperatures, surface finish and coatings. The facilities are used to test developmental alloys and coatings with improved metal dusting resistance.
Click on photo to view a larger image.

High Temperature Corrosion Test Facilities:

We have six corrosion test facilities and two thermogravimetric systems for conducting corrosion tests in complex mixed gas environments, in steam, and in the presence of deposits.

Last Modified: Mon, February 15, 2010 4:47 PM

 

RELATED RESOURCES

Research

Capabilities

For more information:

Corrosion and Mechanics of Materials
Sect. Manager: K. Natesan
Fax:  +1 630-252-3604

K. Natesan's Executive Bio

 

U.S. Department of Energy | UChicago Argonne LLC
Privacy & Security Notice | Contact Us | Site Map | Search   go to top