246.270  Safety of facilities, infrastructure, and equipment for military operations.

 

246.270-1  Scope.

This section implements section 807 of the National Defense Authorization Act for Fiscal Year 2010 (Pub. L. 111-84).  It establishes policies and procedures intended to ensure the safety and habitability of facilities, infrastructure, and equipment acquired for use by DoD military or civilian personnel during military operations performed outside the United States, Guam, Puerto Rico, and the Virgin Islands.

 

246.270-2  Policy.

 

      (a)  Contracts (including task and delivery orders) for the construction, installation, repair, maintenance, or operation of facilities, infrastructure, and equipment configured for occupancy, including but not limited to, existing host nation facilities, new construction, and relocatable buildings acquired for use by DoD military or civilian personnel, shall require a pre-occupancy safety and habitability inspection.

 

      (b)  To minimize safety and health risks, each contract covered by this policy shall require the contractor’s compliance with the Unified Facilities Criteria (UFC) 1-200-01 and its referenced standards for—

 

              (1)  Fire protection;

 

              (2)  Structural integrity;

 

              (3)  Electrical systems;

 

              (4)  Plumbing;

 

              (5)  Water treatment;

 

              (6)  Waste disposal; and

 

              (7)  Telecommunications networks.

 

      (c)  Existing host nation facilities constructed to standards equivalent to or more stringent than UFC 1-200-01 are acceptable upon a written determination of the acceptability of the standards by the Discipline Working Group.

 

      (d)  Inspections to ensure compliance with UFC 1-200-01 standards shall be conducted in accordance with the inspection clause of the contract.

 

246.270-3  Exceptions.

The combatant commander may waive compliance with the foregoing standards when it is impracticable to comply with such standards under prevailing operational conditions.

 

246.270-4  Contract clause.

Use the clause at 252.246-7004, Safety of Facilities, Infrastructure, and Equipment for Military Operations, in solicitations and contracts for the construction, installation, repair, maintenance, or operation of facilities, infrastructure, or for equipment configured for occupancy, planned for use by DoD military or civilian personnel during military operations.

 

 

 