Learn
[Skip Sub Navigation]Flexibility
Today’s workplaces are often in flux. As organizations change direction or develop new services, people also move. Teams form and re-form. People move to new spaces and take on new responsibilities. The spaces themselves are transformed to meet new needs. Conference spaces may be eliminated or added, new groups may be added to existing divisions. These changes are much easier to accommodate, with less stress on people and the organization, when the workplace is designed to support flexibility.
Achieving Both Flexibility and Sustainability: Key Practices
- Move people, not things. Workstation standards minimize the time needed to adjust space when people move to new locations.
- Let people adjust their own workspaces. Adjustable furniture and computer workstations enable people to meet personal preferences and work needs. Furniture on wheels enables easy moves within and between spaces.
- Provide a flexible infrastructure. Demountable walls, under floor data, power and conditioning systems make it easier to transform the workspace in an environmentally friendly way by reducing construction materials, especially hard walls.
- Support mobility within the office. Laptops, cell phones, and wireless connectivity enable people to move easily as their tasks and needs change.
- Support alternative work settings. Enable people to work in spaces outside of the office, such as home or a telework center, to reduce the environmental and economic costs of commuting.
Benefits:
Social:
- Improved employee comfort and satisfaction
- Reduced likelihood of ergonomic-related injuries.
- Reduced employee stress associated with commuting
Economic:
- Reduced costs of moves
- Reduced costs of construction
Environmental:
- Reduced waste from construction
- Reduced energy from commute reduction
Case Study: PBS Chicago Regional Office
Strategy:
Prior to an extensive renovation, the Chicago PBS office had a multitude of workspace types and sizes, making moves time consuming and costly.
The new workplace is significantly more flexible. The open plan workstations and private offices are standardized and conference rooms have demountable walls. A central filing space reduces the demand for individual storage.
Results
- Costs of reconfiguring were reduced from $900 per workstation and $1650 per office to 0 for each.
- Savings of $55,000 to $72,000 per year due to reduced costs of reconfiguring space and cabling.
- Plug and play data and telecom closets enable GSA staff to do workstation changes rather than hiring an external person, with an average cost savings of $125 per change.
Alternative Workplace Lab (AWL): GSA, Washington DC
Key Results from AWL research:
The space has supported three major re-organizations and a 150% increase in staff for the current tenant.
One private office added two touchdown spaces to support staff who live outside of Washington DC.
On move-in day, one team totally reconfigured its work area in 90 minutes.
Project Checklist
- Workstations and private office elements facilitate adjustment and reconfiguration
- Moveable desks
- Moveable storage units
- Moveable task light
- Individual lighting controls
- Individual ventilation control
- Meeting spaces have reconfigurable furniture
- Conference rooms have de-mountable walls to enable reconfiguration or relocation
- Large conference rooms (20 or more people) can be subdivided into smaller spaces with moveable wall partitions
- Space standards for open plan to enable rapid relocation of people
- Flexible utility distribution, such as under floor cabling.to allow changes without demolition and renovation
- Wireless connectivity is provided in all spaces
- Alternative work settings in the office support mobility for associates and support for guests (e.g.,. touch down spaces)
- Alternative work settings outside of the office are supported, such as work at home or at a telework center
- Under floor air distribution or adjustable ceiling system to enable user control of ventilation
Gallery
Did You Know?
Between 1950 and 2000, the U.S. population nearly doubled. However, in that same period, public demand for water more than tripled. Americans now use an average of 100 gallons of water each day—enough to fill 1,600 drinking glasses. Source: EPA WaterSense, Why Water Efficiency?
Case Study
Spatial Equity
Organizations today are less hierarchical and work is more team based, more mobile, and more cross functional. A key to spatial equity is that space layout and workstation standards are based on new ways of working and specific work tasks and business needs rather than organizational hierarchy.
Share Your Story
Do you have a story to share? See and share examples of successes and struggles from our user community in Share