Printable Version | View in New Window | Update Beamline Info

Beamline 14-ID-B: Sector 14 - Insertion Device Beamline

BioCARS
Life Sciences

Description

The 14-ID-B station is an insertion device station with two in-line undulators (U23 and U27). It supports Laue and time-resolved crystallography and time-resolved solution scattering (ns and ps pulsed lasers are available). The ID and bending magnet stations are embedded in a biohazards facility suitable for handling biohazards at the BSL2 and BSL3 levels.  

 

Supported Techniques

  • Time-resolved crystallography
  • Time-resolved x-ray scattering
  • Laue crystallography
  • Wide-angle x-ray scattering
  • Biohazards at the BSL2/3 level
  • Macromolecular crystallography

Beamline Controls and Data Acquisition

Beamline controls: EPICS. Data acquisition: BioCARS-developed GUI. Data processing: HKL2000, Denzo/HKL, MOSFLM, LaueView, Precognition, etc. (See http://cars9.uchicago.edu/biocars/software/software.html for the full list.)

Detectors

  • MAR165

Additional Equipment

  • 60 deg. kappa diffractometer
  • Oxford Cryo-Jet and FTS Air-Jet crystal coolers
  • Carl Zeiss microscope
  • Biosafety cabinet
  • Laser laboratory with cw and pulsed lasers, micro-spectrophotometer
  • Cold room
  • Chemical laboratory

Local Contacts

Name VUKICA SRAJER
Phone 630.252.0455
Name KATHRYN L. TIETZ
Phone 630.252.0450
Name ROBERT W. HENNING
Phone 630.252.0446

Beamline Specs

Source (upstream)

2.7 Undulator

Source (downstream)

2.3 Undulator

Monochromator Type

Si(111)

Energy Range

7-19 keV

Resolution (ΔE/E)

1.4 x 10 -4

Flux (photons/sec)

7 x 10 13 @12 keV

Beam Size (HxV)

 

Focused

95µm x 30µm

For additional information see:
http://cars9.uchicago.edu/biocars/pages/idb.html

Current Status:

Operational/Accepting General Users

Access Mode: