FOR years, scientists conducting shock-physics experiments were limited to measuring sudden velocity increases at only a few discrete points on a target’s surface. For example, as recently as a year ago, the high costs and complexity of setup forced researchers at the National Nuclear Security Administration (NNSA) laboratories to collect velocity data at only a dozen or so points on a moving surface as part of stockpile stewardship experiments. These scientists then used extrapolation, assumptions, and models to determine what was occurring in regions of the experimental target not observed directly. Today, scientists are routinely recording 96 channels of optical velocity data at a fraction of the former cost to acquire data from just a few channels. This new technology, for which its developers earned an R&D 100 Award, is called multiplexed photonic Doppler velocimetry (MPDV). The MPDV system was designed and developed by a team from NNSA’s National Security Technologies (NSTec), LLC, the managing and operating contractor for the Nevada National Security Site and its related facilities, including operations in Los Alamos and Nevada. Senior scientist Ed Daykin led the development team together with Livermore physicist Ted Strand. The project began under NSTec’s Site Directed Research and Development Program, and final development was conducted under the Shock Wave Related Diagnostic Development Project, which addresses the diagnostic needs of the NNSA nuclear design laboratories (Lawrence Livermore, Los Alamos, and Sandia national laboratories) in the area of shock physics. Beat Frequency a Matter of Subtraction PDV is based on determining the “beat frequency,” the difference in frequency between two waves, in this case, the difference in frequencies between a reference laser and the Doppler-shifted light reflected from a moving surface. Over the years, PDV became a standard diagnostic tool available to Livermore researchers. (See S&TR, July/August 2004, This Instrument Keeps the Beat.) Strand explains that although highly reliable, PDV cannot economically provide the many dozens of simultaneous measurements needed to improve physical understanding and experimental accuracy in some stockpile stewardship experiments. In particular, Los Alamos and Lawrence Livermore scientists performing hydrodynamics experiments requested a more portable and cost-effective diagnostic system that could record more than 100 points of optical velocimetry data. Hydrodynamics experiments monitor the movement of a curved imploding surface inside a domelike configuration. In these experiments, the detonation of high explosives sends a shock wave through the test material, causing a liquidlike flow. Liquid behavior is described by hydrodynamic equations, so the experiments are often called hydrotests. (See the related article Simulation and Precision Engineering Lead to Extraordinary Results in Experiment.) More Information at Reduced Cost MPDV uses a fiber-optic interferometer that measures the beat frequency resulting from a combination of the Doppler-shifted light from one laser and the reference light from another laser—an approach referred to as the heterodyne method. The Doppler-shifted light from four different probes is combined with four different reference light frequencies and applied to a photodetector. This process is accomplished within a fiber-coupled system that leverages commercially available telecommunications hardware. The beat frequency is recorded onto a high-bandwidth (20-gigahertz) digitizing oscilloscope and is then analyzed to determine velocity versus time at any of the surface locations that were monitored. With MPDV, scientists can make hundreds of velocity measurements between 0.001 to 30 kilometers per second that are both economical and logistically feasible. The portable MPDV system requires no special laser safety requirements. Proof-of-concept experiments were conducted in early 2011. The technology was first demonstrated at Los Alamos in August and September of that year. MPDV was then fielded on two multimillion-dollar experiments in October and December at Lawrence Livermore and Los Alamos, respectively. On March 7, 2012, a record 96 channels were demonstrated using three MPDV units. By providing scientists with much more high-quality data, MPDV improves the ability to predict shock and material conditions and allows detailed comparisons between computational and experimental results. In this way, the technology helps ensure the safety and security of the nation’s nuclear stockpile. The new capability has potential applications to pulsed-power experiments as well as low-velocity commercial applications such as noncontact measurements of vibration. The team plans to continue development with an eye on increasing channel count, improving cost-effectiveness, and enhancing measurement capabilities. —Arnie Heller Key Words: fiber-optic interferometer, hydrodynamics test, multiplexed photonic Doppler velocimetry (MPDV), R&D 100 Award, shock physics. For further information contact Natalie Kostinski (925) 423-1890 (kostinski1@llnl.gov).
|
||||||||||||||
S&TR Home | LLNL
Home | LLNL Site Map | Top Lawrence Livermore National Laboratory Privacy & Legal Notice | UCRL-TR-52000-12-10/11 | October 1, 2012
|