skip navigation links 
 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Integrated Chemical Effects Test Project: Test #2 Data Report (NUREG/CR-6914)

On this page:

Download complete document

The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.


Publication Information

Manuscript Completed: August 2006
Date Published: December 2006

Principal Investigator: J. Dallman

Prepared by
J. Dallman, B. Letellier, J. Garcia, M. Klasky
W. Roesch, J. Madrid
Los Alamos National Laboratory
Los Alamos, NM 87545

K. Howe, D. Chen
University of New Mexico
Department of Civil Engineering
Albuquerque, NM 87110

B.P. Jain, NRC Project Manager

Prepared for
Division of Fuel, Engineering and Radiological Research
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC Job Code Y6999

Availability Notice


Abstract

A 30-day test was conducted in the Integrated Chemical Effects Test (ICET) project test apparatus. The test simulated the chemical environment present inside a pressurized water reactor containment water pool after a loss-of-coolant-accident. The initial chemical environment contained 14.54 kg of boric acid and 0.663 g of lithium hydroxide (LiOH). Trisodium phosphate (3.786 kg), hydrochloric acid (211 mL), and additional boric acid (600 g) were added beginning
at 30 minutes and lasting until 4 hours into the test. The test was conducted for 30 days at a constant temperature of 60°C (140°F). The materials tested within this environment included representative amounts of submerged and unsubmerged aluminum, copper, concrete, zinc, carbon steel, and insulation samples. Representative amounts of concrete dust and latent debris were also added to the test solution. Water was circulated through the bottom portion of the test chamber during the entire test to achieve representative flow rates over the submerged specimens. The test solution reached a pH of 7.3, and the test solution turbidity steadied out at approximately 1 NTU after 5 days. No precipitates were observed in the solution, but large amounts of white deposits (nominally 0.125 to 0.250 in. in diameter) were observed on the submerged galvanized steel, aluminum, and inorganic zinc, coated steel coupons. The test solution remained clearly Newtonian for the entire test. Aluminum was not detectable in the solution. Calcium, magnesium, silica, and sodium were prevalent in the solution.



Privacy Policy | Site Disclaimer