Electricity

‹ See entire Electric Power Annual

Electric Power Annual 2010 Data Tables

With Data for 2010   |  Release Date:  November 09, 2011   |  Next Release Date: November 2012

Table A3. Carbon Dioxide Uncontrolled Emission Factors
(Pounds of CO2 per Million Btu)
Fuel, Code, Source, and Emission Factor
Fuel And EIA Fuel Code Source and Tables (As appropriate) Factor (Pounds of CO2 Per Million Btu)***
Bituminous Coal (BIT) Source: 1 205.3
Distillate Fuel Oil (DFO) Source: 1 161.386
Geothermal (GEO) Estimate from EIA, Office of Integrated Analysis and Forecasting 16.59983
Jet Fuel (JF) Source: 1 156.258
Kerosene (KER) Source: 1 159.535
Lignite Coal (LIG) Source: 1 215.4
Municipal Solid Waste (MSW) Source: 1 (including footnote 2 within source) 91.9
Natural Gas (NG) Source: 1 117.08
Petroleum Coke (PC) Source: 1 225.13
Propane Gas (PG) Source: 1 139.178
Residual Fuel Oil (RFO) Source: 1 173.906
Synthetic Coal (SC) Assumed to have emissions similar to Bituminous Coal. 205.3
Subbituminous Coal (SUB) Source: 1 212.7
Tire-Derived Fuel (TDF) Source: 1 189.538
Waste Coal (WC) Assumed to have emissions similar to Bituminous Coal. 205.3
Waste Oil (WO) Source: 2, Table 1.11-3 (assumes typical heat content of 4.4 MMBtus per barrel) 210
Note:
*** CO2 factors do not vary by combustion system type or boiler firing configuration.
Sources: Energy Information Administration, Office of Integrated Analysis and Forecasting, Voluntary Reporting of Greenhouse Gases Program, Table of Fuel and Energy Source: Codes and Emission Coefficients; available at: http://www.eia.doe.gov/oiaf/1605/coefficients.html; and U.S. Environmental Protection Agency, AP 42, Fifth Edition (Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources); available at: http://www.epa.gov/ttn/chief/ap42/.