Refining Kettle Emissions Control

Design Characteristics:
  • Volume flow rate of kettle surface area
  • Dust Velocity greater than or equal to 4000 FPM
Construction Notes
  • Enclose to provide at least 250 FPH face velocity at all openings
  • Provide adequate lifting points for hood assembly associated ductwork