A portable microcomputer has been developed for the IAEA to perform in-field analysis of plutonium gamma-ray spectra. The unit includes a 16-bit LSI-11/2 microprocessor, 32K words of memory, a 20-character display for user prompting, and a 20-character thermal printer for hardcopy output. Only the positions of the 148-keV Pu-241 and 208-keV U-237 peaks are ...
Energy Citations Database
This work presents an intercomparison between commercial software for alpha-particle spectrometry, Genie 2000, and the new free available software, Winalpha, developed by International Atomic Energy Agency (IAEA). In order to compare both codes, different environmental spectra containing plutonium, uranium, thorium and polonium have been analyzed, together ...
PubMed
Further to the inter-comparison runs of gamma spectra processing programs organized in 1974 by the Laboratoire de Mesure de Rayonnements Ionisants and in 1976 by the IAEA, in which many laboratories partook, the members of the 'Gamma Spectrometry' Working...
National Technical Information Service (NTIS)
The experiments were carried out to test and evaluate the Gamma Spectrometry Data Processor Unit developed for the IAEA safeguards. In the report the results of Pu isotopic ratios obtained by the Data Processor and by the IAEA Nuclear Data 6620 using the ...
In response to Task A.63 of the International Safeguards Project Office (ISPO), to upgrade measurement technology used by the International Atomic Energy Agency (IAEA), a portable data-reduction microprocessor was designed and programmed which allows in-field reduction of gamma-ray spectra and interfaces with the IAEA's ...
The purpose of this paper is to compare the tissue equivalence and tissue kerma for dosimetric tissue-equivalent detectors with allowance for the neutron spectra. Results are given for the calculated dose sensitivities for the DINA and GNEIS dosemeters for a portion of the neutron spectra recommended by IAEA for comparative ...
The object of this study is to remove some of the uncertainties associated with the application of the IAEA Regulations insofar as they apply to Special Form materials. The first part of this project involved a comparison of the ISO and IAEA Regulations. ...
Examples of data from IAEA leach tests on spent fuel elements are shown that were displayed, not in the recommended manner in the IAEA leach test, but in the manner of the modifications of this leach test. The main difference in the display methods is in the plotting of incremental leach rates ...
... Development Test and Evaluation (RDT&E) data. ... RADIOACTIVE MATERIALS, INTERNATIONAL, TREATIES, NUCLEAR PROPERTIES. ...
DTIC Science & Technology
The IAEA Code of Practice TRS 277 gives recommendations for absorbed dose determination in high energy photon and electron beams based on the use of ionisation chambers calibrated in terms of exposure or air kerma. The scope of the present work was to tes...
Lower hybrid current drive (LHCD) is currently under consideration for off-axis current profile control in the ITER device. Upcoming LHCD experiments in the Alcator C-Mod tokamak will be performed in a wave physics regime close to that of ITER where B 5T, ne 1 x 10^20 m-3, and (?pe / ?ce)^2 1 and are therefore ideally suited to test physics issues related to off-axis ...
NASA Astrophysics Data System (ADS)
Since 1993, the IAEA has made great progress in the implementation of remote monitoring. Equipment has been developed and tested, and installed systems are being used for safeguards purposes. The cost of equipment, the complexity of communication technology, and maintenance of the equipment are challenges that still face the IAEA. ...
DOE Information Bridge
... Corporate Author : SANDIA NATIONAL LABS ALBUQUERQUE NM. ... Sandia also conducts prescriptive fire testing for the IAEA, NRC and the DOT. ...
This paper develops a general approach for International Atomic Energy Agency (IAEA) authentication of nuclear material assays made with in-plant instruments under facility operator control. The IAEA is evaluating the use of in-plant instruments as a part of international safeguards at large bulk-handling facilities, such as reprocessing plants, fuel ...
This paper describes a potential approach by which the International Atomic Energy Agency (IAEA) might verify the nuclear-material balance at the Portsmouth Gas Centrifuge Enrichment Plant (GCEP), should that plant be placed under IAEA safeguards. The strategy makes use of the attributes and variables measurement verification approach, whereby the ...
Hanford Site operators combine gamma ray isotopic and calorimetry measurements for nondestructive plutonium assay. Such measurements offer lower variability (particularly for heterogeneous materials) and decreased radiation exposure, cost, waste, intrusiveness, and material handling compared to destructive analysis. Until now, the International Atomic Energy Agency (IAEA) has ...
This bulletin, published by the IAEA, provides atomic and molecular data references relevant to fusion research and technology. In part I the indexation of the papers is provided separately for (i) structure and spectra, (ii) atomic and molecular collisio...
This work is a continuation of the work performed within the IAEA programme on standardization of reactor radiation measurements, one of the important objectives of which is the assistance to laboratories in Member States to implement or intercompare the ...
Spent fuels with burnups of 9000, 28,000 and 54,500 MWd/MTU have been leach tested at 25 exp 0 C. Three leach-test procedures (Paige, IAEA and static) were used. IAEA and static tests were conducted in five different solutions: deionized water, sodium bic...
A number of pellets and highly durable glasses prepared from nonradioactive-simulated high-level waste calcines have been leach tested. The leach tests are patterned on the IAEA standard test and the proposed Materials Characterization Center tests. Most ...
A number of pellets and highly durable glasses prepared from nonradioactive-simulated high-level wasste calcines have been leach tested. The leach tests are patterned on the IAEA standard test and the proposed Materials Characterization Center tests. Most...
The International Atomic Energy Agency's (IAEA) Department of Safeguards uses complex instrumentation for the application of safeguards at nuclear facilities around the world. Often, this equipment is developed through cooperation with member state support programs because the Agency's requirements are unique and are not met by commercially available ...
The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) established a Network of Secondary Standards Dosimetry Laboratories (IAEA/WHO SSDL Network) in 1976. Through SSDLs designated by Member States, the Network provides a direct link of national dosimetry standards to the international measurement system of standards ...
... OF TECH WRIGHT-PATTERSON AFB OH SCHOOL OF ENGINEERING. ... and tested on a test spectrum wtih a ... in reproducing this test spectra and no ...
This paper describes a potential approach by which the International Atomic Energy Agency (IAEA) might verify the nuclear-material balance at the Portsmouth Gas Centrifuge Enrichment Plant (GCEP). The strategy makes use of the attributes and variables measurement verification approach, whereby the IAEA would perform independent measurements on a randomly ...
... REFLECTIVITY, GRASSES, ULTRAVIOLET SPECTRA, VISIBLE SPECTRA, BRIGHTNESS, MODEL TESTS, LIGHT TRANSMISSION, USSR. ...
This paper presents the implementation of the training received through the IAEA Project 'Preparation of Reference Materials and Organization of Proficiency Tests Rounds' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out ...
This paper presents the implementation of the training received through the IAEA Project ``Preparation of Reference Materials and Organization of Proficiency Tests Rounds'' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out by the NAT ...
This report contains the actual status of the Belgian contribution to the IAEA CRP-IV program. Besides Charpy-V impact tests on as-received CRP-IV JRQ- specimens, fracture toughness tests were performed on two geometries: PCCV- specimens and CRB-specimens...
The designation 'special form' may be applied to indispersible solid radioactive material if the material meets the requirements of the tests described in the International Atomic Energy Agency Regulations for the Safe Transport of Radioactive Type Materi...
Two 3600 kg transport flasks made of mild steel have been instrumented with thermocouples and subjected to typical thermal tests, as specified in the 1973 IAEA Advisory Document. One of the tests was in a furnace and the other in a fire. From the recorded...
Two scientists from the U.S. Department of Energy`s Environmental Measurements Laboratory served as scientific experts to the International Atomic Energy Agency`s (IAEA) Mission to Kazakhstan: Strengthening Radiation and Nuclear Safety Infrastructures in Countries of the former USSR, Special Task - Preassessment of the radiological situation in the Semipalatinsk and western ...
A remote monitoring system (RMS) field trial will be conducted for the International Atomic Energy Agency (IAEA) on highly enriched uranium materials in a vault at the Oak Ridge Y-12 Plant. Remote monitoring technologies are being evaluated to verify their capability to enhance the effectiveness and timeliness of IAEA safeguards in storage facilities while ...
The IAEA continues to assess, develop, and test recommendations for strengthening the cost effectiveness of safeguards. The IAEA`s investigation has focused on ways to increase Agency access to data, including access to sites and site data, export/import data, environmental data, open-source data, and other expanded data sources. ...
For many years the well-established Kayzero for Windows software for neutron activation analysis (NAA) using k0 standardization was the only commercial program available. Recently, the freeware k0-IAEA software has been launched by the International Atomic Energy Agency (IAEA). The software is based on an adapted H�gdahl convention in which the cadmium ...
A precise quantitative analysis with the neutron radiography technique of materials with a high-neutron scattering cross section, imaged at small distances from the detector, is impossible if the scattering contribution from the investigated material onto the detector is not eliminated in the right way. Samples with a high-neutron scattering cross section, e.g. hydrogenous materials such as water, ...
... Accession Number : ADA199882. Title : Testing and Evaluation of SURLYN Foam and SPECTRA Fiber Ropes for Buoy Systems Applications. ...
... Accession Number : ADA252031. Title : A Test of the Possibility of Calculating Absorption Spectra by Mixed Quantum-Classical Methods. ...
Based on results of an International Atomic Energy Agency (IAEA) field test of the prototype 20-ton-capacity Load-Cell-Based Weighing System (LCBWS), a modified LCBWS is being configured for routine IAEA field use in verifying the masses of 10- and 14-ton...
The International Atomic Energy Agency (IAEA) runs the Assessment of Safety Significant Event Team (ASSET) services for assessing safety performance at nuclear power plants. The aim of the ASSET missions is to prevent incidents and accidents. The way to achieve this is through the analyses of the safety relevant events experienced during operation, ...
Additional subsurface investigations of the Rio Blanco detonation region and adjacent reservoir have been underway since the last technical meeting at IAEA. The lowermost explosion cavity has been reentered and a production test from it was performed. A d...
Investigations are reported on reducing cesium and strontium leachability from products formed at the cementation of intermediatelevel waste solutions from reprocessing plants. The leach tests used were the IAEA method and an accelerated test. One particu...
A modified IAEA leach test was used to evaluate the relative performance of potential saltstone formulations. The effects of sample size and leach rates for specific ions were determined. Nitrite, nitrate, sodium, and sulfate are listed in order of decreasing leach rates and effective diffusivities for saturated leaching of saltstone. This paper discusses ...
The IAEA convened the Advisory Group to (1) consider any available data on transport accidents and any risk assessments performed in Member States, with a view to making a critical study of the continuing adequacy of the package test requirements included...
The IAEA will require advanced technologies to effectively safeguard nuclear material at envisioned large scale nuclear reprocessing plants. This dissertation describes results from simulations and experiments designed to test the Multi-Isotope Process (MIP) Monitor, a novel safeguards approach for process monitoring in reprocessing plants. The MIP Monitor ...
Performance requirements and testing protocols are needed to ensure that equipment used by the International Atomic Energy Agency (IAEA) is reliable. Oak Ridge National Laboratory (ORNL), through the US Support Program, tested equipment to validate performance requirements protocols used by the IAEA for the subject ...
For the past 15 years, the International Atomic Energy Agency (IAEA) has had a major interest in helping its member states to diagnose livestock diseases through the development and validation of diagnostic tests for trans-boundary animal diseases. In November, 2007, an IAEA consultants meeting attended by experts, OIE members and ...
An Active Well Coincidence Counter (AWCC) and a portable shift register (PSR-B) produced by Aquila Technologies Group, Inc., have been tested and cross-calibrated with existing AWCCs used by the International Atomic Energy Agency (IAEA). This report summarizes the results of these tests and the cross-calibration of the detector. In ...
The BN-350 Unattended Monitoring System plays an important role for the Safeguards Department of the International Atomic Energy Agency (IAEA). In 1998, the Los Alamos National Laboratory, in conjunction with the IAEA and sponsored by the US Department of Energy, designed and installed an integrated multi-instrument safeguards system at the BN-350 reactor ...
The IAEA (International Atomic Energy Agency) code of practice TRS 277 gives recommendations for absorbed dose determination in high energy photon and electron beams based on the use of ionization chambers calibrated in terms of exposure of air kerma. The scope of the work was to test the code for cobalt 60 gamma radiation and for several radiation ...
Since 1993, the IAEA has made great progress in the implementation of remote monitoring. Equipment has been developed and tested, and installed systems are being used for safeguards purposes. The cost of equipment, the complexity of communication technolo...
IAEA (International Atomic Energy Agency) Safety Series n. 6 states that, to ensure compliance with the Regulation, the programs of quality assurance must be put in practice either for design, manufacture, testing, documentation, use and maintenance and i...
Analytical results need to be reliable, and analysts are well serviced to test their complete analytical systems, methods, instruments, personnel, data reduction, etc., on a frequent basis. Besides the use of standard reference materials, the intercompari...
The main dificulties faced in the implementation of the WASP-III on the Honeywell Bull DPS 6/64 computer at CNEN, are discribed. After the implementation, tests making use of input data provided by International Atomic Energy Agency, IAEA, were performed ...
Two scientists from the U.S. Department of Energy's Environmental Measurements Laboratory served as scientific experts to the International Atomic Energy Agency's (IAEA) Mission to Kazakhstan: Strengthening Radiation and Nuclear Safety Infrastructures in ...
IAEA regulations require that packages containing more than a very small amount of radioactive or fissile material must withstand a drop from 9 m onto a target which is a flat, horizontal surface without escape of radioactive material, increase of externa...
As the final report of a three-year project carried out in the IAEA dosimetry laboratory on 'Design and construction of a portable graphite calorimeter', the construction, mode of operation, testing and performances of a prototype and four production unit...
The document reproduces the statement adopted by the Zangger Committee on the recent nuclear tests conducted by India and Pakistan, which was received on 26 June 1998 by the Director General of the IAEA from the Permanent Mission of the United Kingdom to ...
The first edition of the Directory of IAEA Databases is intended to describe the computerized information sources available to IAEA staff members. It contains a listing of all databases produced at the IAEA, together with information on their availability...
The International Atomic Energy Agency (IAEA) will require the development of advanced technologies to effectively safeguard nuclear material at increasingly large-scale nuclear recycling facilities. Ideally, the envisioned technologies would be capable of nondestructive, near-real-time, autonomous process monitoring. This paper describes recent results from model simulations ...
The International Atomic Energy Agency (IAEA) has supported neutron radiation effects information exchange through meetings and conferences since the mid-1960s. Through an International Working Group on Reliability of Reactor Pressure Components, information exchange and research activities were fostered through the Coordinated Research Program (CRP) sponsored by the ...
The test series described in this paper has shown that the proposed dynamic crush test or the alternate static crush test result in significantly greater packaging deformation than occurs when the regulatory 9 meter drop test is performed on lightweight, ...
The Kozloduy NPP is located in the North-West part of Bulgaria on the Danube river. The plant consists of four units of 440 MW and two units of 1,000 MW. In the last 15 years there have been three strong, intermediate depth earthquakes in the Vrancea seismic zone (1977, 1986, 1990) which have affected the NPP site. The Vrancea zone is located approximately 300 km northeast of the plant. It is ...
... HAZARDS, EMISSION SPECTRA, TEST EQUIPMENT, ELECTRON SPIN RESONANCE, ULTRAVIOLET SPECTROSCOPY, VISIBLE SPECTRA ...
... Abstract : The experimental tests by Okamoto and Drickamer of the Drickamer model of high-pressure effects on electronic spectra are reexamined. ...
... Proton recoil spectra and Compton electron spectra were unfolded with the neutron and gamma unfolding code FORIST to generate the incident ...
... Accession Number : AD0621906. Title : TESTS FOR RANDOMNESS, STATIONARITY, NORMALITY AND COMPARISON OF SPECTRA. ...
... Accession Number : AD0247707. Title : ACCEPTANCE TEST FOR PRESERVATIVE LUBRICANTS BASED ON INFRARED SPECTRA. ...
The radioactivities of 14 MeV neutron irradiated Molybdenum foils have been measured for comparison exercise conducted by the IAEA Nuclear Data Section. The spectra of the characteristic gamma-rays emitted as a result of the induced radioactivity were tak...
A state-of-the-art video surveillance system, the Modular Integrated Video System (MIVS), has been developed by Sandia National Laboratories for the International Atomic Energy Agency (IAEA). The development of this system was sponsored by the U.S. Department of Energy and the U.S. Program of Technical Assistance to IAEA Safeguards. The development of the ...
Several intercomparison exercises were organised by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or interregional basis. In East Asia region, a third phase of the intercomparison finished in mid 2004. It was organised within the frame of the Regional Cooperation Agreement (RCA) as a follow-up to previous exercises ...
Searchable database by country. The results can be viewed as a summary or a reactor list. "The purpose of this site is to enable access to the IAEAs Research Reactor Data Base (RRDB). It contains administrative, technical and utilization information on research reactors, training reactors, test reactors, prototype reactors and critical assemblies ...
NSDL National Science Digital Library
The IAEA is currently bringing into routine use safeguards equipment based on new technology. In many cases, bringing this new equipment to the point of routine use has required a surprisingly long time. This survey of equipment development is directed at describing the experience gained in introducing new equipment for IAEA safeguards. The experience ...
This report gives details of the tests for normal transport (Type A tests) and accident conditions (Type B tests) carried out on the AWE(A) packaging assembly AWG 446Eu4 and demonstrates the ability of the packaging to remain leaktight after the tests wit...
The new IRDF-2002 dosimetry cross-section library was completed by the IAEA in January 2004. A rigorous process was followed in the selection of the recommended dosimetry cross sections. The cross-section selection was followed with a consistency testing. This paper reports on the results of the consistency testing. All candidate ...
A sophisticated program for isotopic analysis of plutonium gamma-ray spectra using small computers has been developed. It is implemented on a DEC LSI-11/2 configured in a portable unit without a mass storage device for use by IAEA inspectors in the field. Only the positions of the 148-keV /sup 241/Pu and 208-keV /sup 237/U peaks are needed as input. ...
The Modular Integrated Video System (MIVS) Image Processing System (MIPS) was developed to assist the International Atomic Energy Agency (IAEA) Inspectorate in the safeguards review of MIVS Surveillance data. MIPS is designed to review MIVS surveillance data automatically; firstly detecting significantly changed images and secondly identifying if the changed images show ...
The proliferation of nuclear weapons is a great threat to world peace and stability. The question of strengthening the nonproliferation regime has been open for a long period of time. In 1997 the International Atomic Energy Agency (IAEA) Board of Governors (BOG) adopted the Additional Safeguards Protocol. The purpose of the protocol is to enhance the ...
E-print Network
This presentation discusses the International Atomic Energy Agency (IAEA) and the control of radioactive sources.
... Title : THE IAEA SYSTEM AND EXPERIENCE AS A MODEL FOR INFORMATION MANAGEMENT UNDER THE CHEMICAL WEAPONS ...
The second Standard Problem sponsored by IAEA consists in the simulation of a small LOCA located in the downcomer of a PMK-NVH integral test facility, which models WWER/440 type reactor. This report presents input data preparation and comparison between T...
The International Atomic Energy Agency (IAEA)'s Environmental Modelling for Radiation Safety (EMRAS) model evaluation programme includes a Tritium and Carbon-14 Working Group (TCWG), the goal of which is to test the performance of models for the environmental transfer. This paper describes work on two of the nine TCWG scenarios; one involved the prediction ...
A three dimensional (3-D) heat transfer computer code was developed to study and optimize the design parameters and to better understand the performance characteristics of the IAEA's air-bath calorimeters. The computer model accounts for heat conduction and radiation in the complex materials of the calorimeter and for heat convection and radiation at its outer ...
A system of computer programs for recognizing inpure or mixed spectra was assembled that provided automatic subtraction of reference mass spectra from a mixed spectrum. The software was 99% successful in recognizing pure spectra for the cases tested. Subtractions were done on mix...
EPA Science Inventory
The Kori No.1, which began operation in 1978, replaced its cask handling crane in 2000. To prove the safety of recycling and reuse of crane scrap, a particular calculation method for surface contamination was used. Because surface radioactive contamination of steel is limited to a few-microns-thick layer, we can calculate the total(removable and fixed contamination) activity of the sample ...
This website charts the progress made by countries that are emerging nuclear energy producers. An emerging country is defined as a nation whose government has expressed an interest in a civilian nuclear power program with the assistance of established nuclear suppliers and the International Atomic Energy Agency (IAEA). The site�s interactive table presents the current (2009) ...
The IAEA has been involved for more than twenty years in supporting international nuclear non- proliferation efforts associated with reducing the amount of highly enriched uranium (HEU) in international commerce. IAEA projects and activities have directly supported the Reduced Enrichment for Research and Test Reactors (RERTR) ...
Based on results of an International Atomic Energy Agency (IAEA) field test of the prototype 20-ton-capacity Load-Cell-Based Weighing System (LCBWS), a modified LCBWS is being configured for routine IAEA field use in verifying the masses of 10- and 14-ton UF/sub 6/ cylinders. The modified system is being designed to meet ...
The International Atomic Energy Agency (IAEA) coordinates the work of a world-wide network of analytical laboratories, the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network. A proficiency test for ALMERA members was organized in 2006 based on the determination of gamma-emitting radionuclides ((54)Mn, (60)Co, ...
The Modular Integrated Video System (MIVS) was developed to provide a replacement surveillance system for the IAEA's Twin Minolta Film Camera System. This task was sponsored by the Department of Energy (DOE) and the US Program for Technical Assistance to IAEA Safeguards (POTAS). This is the final report describing the development, ...
Mushroom reference materials have been prepared and characterized for the use in proficiency tests according to a procedure established within the frame of an IAEA Interregional Technical Cooperation Project. The materials were used for conducting the proficiency tests in Poland in 2005-2007. The results obtained by participating ...
This report outlines the analytical work on the first test case, Test Case 1, specified by the IAEA sponsored co-operative research programme on the safety assessment of near-surface radioactive waste disposal facilities. Descriptions are provided on anal...
This report summarizes and evaluates field tests of the Active Well Coincidence Counter (AWCC) at Winfrith and Dounreay, United Kingdom. The applicability of the AWCC for assaying the uranium content of a wide variety of materials was demonstrated and calibration curves were generated. The AWCC was used in three modes (fast, thermal, and passive) while assaying powders, ...
A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data ...
A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: (1) a data-transfer application for transferring spectral ...
It has long been United States Government (USG) policy to actively support nuclear nonproliferation efforts, as evinced in the 1970 US ratification of the Nuclear I Nonproliferation Treaty (NPT) and the 1978 US Voluntary Treaty with the IAEA (INFCIRC/288). Under INFCIRC 288, US facilities without direct national security involvement are eligible for International Atomic Energy ...
... NONDESTRUCTIVE TESTING, OPTICAL PROPERTIES, RAMAN SPECTRA, RAMAN SPECTROSCOPY, SEMICONDUCTORS, SILICON ...
... Descriptors : *OXIDES, *PHOTOELECTRON SPECTRA, *NIOBIUM COMPOUNDS, TEST AND EVALUATION, OPTICAL PROPERTIES, MODELS ...
... Descriptors : *DENSIMETERS, *RADIOACTIVE ISOTOPES, GAMMA EMISSION, RADIOMETERS, SOILS, ABSORPTION SPECTRA, USSR. ...
... TEST REACTORS, *RESEARCH REACTORS, REACTOR SHUTDOWN, REACTOR CONTROL, POWER SPECTRA, NOISE ANALYZERS ...
... an energetic particle such as a recoil proton or Compton ... It is the energy spectra of these recoil protons and electrons which are then recorded in the ...
... Abstract : Random vibration, a test screen found to be extremely effective for disclosing workmanship problems in various equipment, is also ...
... funded research, testing and training ... rocket engine test data, the ... SPECTRA, RESONANT FREQUENCY, RESPONSE, BOOSTER ROCKET ...
... for in vitro testing are Vaccinia ... Descriptors : , , ADENOVIRUSES, ANIMALS, ANTIVIRAL AGENTS ... SPECTRA, TARGETS, TEST AND EVALUATION ...
... for in vitro testing are Vaccinia ... AGENTS, ADENOVIRUSES, ANIMALS, BIOLOGY, CHEMICAL ... SPECTRA, TARGETS, TEST AND EVALUATION ...
... for invitro testing are Vaccinia ... AGENTS, ADENOVIRUSES, ANIMALS, BIOLOGY, CHEMICAL ... SECONDARY, SPECTRA, TEST AND EVALUATION ...
... mitigate electromagnetic spectrum concerns throughout the system's acquisition life cycle. Descriptors : *ELECTROMAGNETIC SPECTRA, *TEST ...
... LIFE EXPECTANCY(SERVICE LIFE), EXCITATION, LABORATORY EQUIPMENT, TEST EQUIPMENT, TEST METHODS, ATOMS, VIBRATION ...
The nuclear spent fuel transport and storage cask is used for transport of the spent fuel from a nuclear power station to an intermediate storage facility. Leak tightness and subcriticality on transportation required from IAEA TS-R1[1] have to be assured by a 9 m drop test and its numerical simulation. This paper describes the drop ...
This report describes the application of methodology for planning an inspection according to the procedures of the International Atomic Energy Agency (IAEA), and an example evaluation of data representative of low-enriched uranium fuel fabrication facilities. Included are the inspection plan test criteria, the inspection sampling plans, the sample data ...
The report gives a brief description of the nature of the radioactive wastes generated at the IAEA Laboratories in Seibersdorf, their origin and composition, their management and monitoring. The management of the radioactive waste produced at IAEA Laborat...
The objectives of the work discussed in this report were to: (1) develop a flow loop that would simulate the purified uranium-bearing aqueous stream exiting the solvent extraction process in a natural uranium conversion plant (NUCP); (2) develop a test plan that would simulate normal operation and disturbances that could be anticipated in an NUCP; (3) use the flow loop to ...
The LR-56 cask is an International Atomic Energy Agency (IAEA), type B (U) certified Medium to High Level Radioactive Liquid Waste Transport Cask. The LR-56 consists of a trailer equipped with the following component and systems: 4 cubic meter lead shield...
Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the qua...
The present report contains the summary of the IAEA Consultants' Meeting on ''First Results of FENDL-1 Testing and Start of FENDL-2''. The meeting conclusions and recommendations and future plans for the development of a nuclear data base for fusion react...
Current requirements for flask testing involve the recommended IAEA 9m drop test onto a flat unyielding surface. However, in practice impacts may occur at speeds far greater than the 30 mph equivalent of a 9m drop but into a yielding target. Additionally,...
Sep 7, 2007 ... observe the longwave feedbacks of the climate system in timeseries of annual average outgoing longwave spectra. ...
NASA Website
JPL has modeled the Mars surface solar spectra, modified an X-25 solar simulator, and completed testing of Mars-optimized solar cells previously developed by ...
... Title : PRESSURE SPECTRA AND SPACE CORRELATIONS FROM AERODYNAMIC NOISE TEST, AD-366 P-1, SPO NO. 149 AND 150,. ...
... a mixture tests also used one input mineral, but with ... for large spectra of several of the minerals were very ... the spectra of illite and chlorite in parallel ...
The U.S. Support Program (USSP) to IAEA Safeguards priority of destructive analysis is aimed at strengthening the IAEA's ability to use destructive analysis as a safeguards tool. IAEA inspectors bring back nuclear and environmental samples from inspection...
The presentation covers the following areas: the wide spectrum of media outlets that the IAEA seeks to serve and their differing needs; the resources available to the IAEA for that purpose; the way in which IAEA endeavours to disseminate authoritative, re...
This issue gives brief information on the following topics: IAEA Director General Addresses United Nations, IAEA Board of Governors' December Meetings, UN General Assembly Commends Work of IAEA, Oceanographic Investigations of Radioactive Pollution, Cance...
...false Communication of information to IAEA. 75.12 Section 75.12 Energy...NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information...12 Communication of information to IAEA. (a) Except as otherwise...
Code of Federal Regulations, 2010
A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ran...
Dominating ?-particle heating will be the qualitatively new physics element of ITER. As it constitutes both a conceptually challenging as well as a practically highly relevant field, it has attracted the attention of a large and growing scientific community. Theoretical and diagnostic tools should be fully developed at the commencement of the thermonuclear operation of ITER. Fortunately effective ...
... The United States and the world have a great interest in the IAEA's success. ... Key Points Strengthening the IAEA: How the ...
... Accession Number : ADD344508. Title : Radiation Safety in Industrial Radiography; IAEA Safety Report,. Corporate Author : ...
... Title : Documentation and Analysis of IAEA (International Atomic Energy Agency) Safeguards Implementation at the Exxon Nuclear Fuel Fabrication ...
The international community in the post-Cold War period has expressed an interest in the International Atomic Energy Agency (IAEA) using its expertise in support of the arms control and disarmament process in unprecedented ways. The pledges of the US and Russian presidents to place excess defense materials under some type of international inspections raises the prospect of ...
Environmental sampling (ES) is a key component of International Atomic Energy Agency (IAEA) safeguarding approaches throughout the world. Performance of ES (e.g. air, water, vegetation, sediments, soil and biota) supports the IAEAs mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a State and has ...
The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA ...
Quality assurance of external-beam treatment-planning systems is recommended, and this can be partly achieved with predefined type tests. The beam data and test geometries of IAEA TECDOC 1540 have been used to test the analytical anisotropic algorithm (AAA) and pencil-beam convolution (PBC) algorithm of the Varian ...
PubMed Central
... of Spray Nozzles Using a Standardized Testing Protocol. ... size spectra for each test were input in ... DRIFT, *WIND TUNNEL TESTS, *SPRAY NOZZLES ...
This paper reports on the most recent efforts of US technical experts to explore verification by IAEA of unclassified attributes of classified excess fissile material. Two propositions are discussed: (1) that multiple unclassified attributes could be declared by the host nation and then verified (and reverified) by the IAEA in order to provide confidence ...
The United States is considering the offer of irradiated research reactor spent fuel (RRSF) for international safeguards applied by the International Atomic Energy Agency (IAEA). The offer would be to add one or more spent fuel storage basins to the list of facilities eligible for IAEA safeguards. The fuel to be safeguarded would be stored in basins on the ...
The modified truncated singular value decomposition (MTSVD) unfolding method is applied to obtain primary spectra for X-ray tubes in radiodiagnostic. Three parameters - voltage, anode angle and filter thickness - of the tube are tested. Unfolded spectra are compared with theoretical extracted from IPEM-78 catalogue. A 2? error ...
. International Atomic Energy Agency, Vienna, Aus- tria, pp. 13�29. Motz, J.E., 2000. Oxygen and hydrogen isotopes upon heating and is captured in the quartz envelope for analysis. Tests with standard polyethylene foil and recalibration of this technique. ZThe materials chosen were polyethylene foil IAEA Table 1 Actual and measured d
Special Form encapsulation has been used at Oak Ridge National Laboratory to ship radioactive solids for the past fifteen years. A family of inexpensive stainless steel containers has been developed and tested to meet the USA Department of Transportation (DOT) and the International Atomic Energy Agency (IAEA) regulations concerning radioactive material ...
Radionuclide determinations on seventeen field trial test samples were carried out for the International Atomic Energy Agency by the Finnish Centre for Radiation and Nuclear Safety (STUK). All the samples, i.e., samples of sea water, grass and biota were ...
The report contains 40 papers that are printed in the order of their presentation in each session and describe recent large-scale fracture (brittle and/or ductile) experiments, analyses of these experiments, and comparisons between predictions and experim...
... partially funded by financial assistance from the International Atomic Energy Agency under its Research Agreement with the Okanagan� ... October 1992, Vienna. IAEA-SM-327/ 29, International Atomic Energy A...
NBII National Biological Information Infrastructure
An experiment was organised at Harwell to test nuclear accident dosimetry (NAD) systems from some 17 laboratories in 13 countries. Dosimeters were irradiated by the Viper reactor at Aldermaston which gave a well moderated neutron spectrum with a broad pea...
The Modular Integrated Video System (MIVS) is intended to provide a simple, highly reliable closed circuit television (CCTV) system capable of replacing the IAEA Twin Minolta Film Camera Systems in those safeguards facilities where mains power is readily available, and situations where it is desired to have the CCTV camera separated from the CCTV recording console. This paper ...
Leach tests were conducted using a modified version of the IAEA procedure to study the behavior of glass waste-solution interactions. Release rates were determined for Tc, U, Np, Pu, Am, Cm, and Si in the following solutions: WIPP B salt brine, NaCl (287 ...
The use of resin beads for mass spectrometry of U and Pu has been extensively developed at Oak Ridge National Laboratory in the USA and tested in a number of intercomparison experiments between the Safeguards Analytical Laboratory (SAL) of the IAEA and th...
This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). T...
Recent extensions and improvements of the EMPIRE code system are outlined. They add new capabilities to the code, such as prompt fission neutron spectra calculations using Hauser-Feshbach plus pre-equilibrium pre-fission spectra, cross section covariance matrix calculations by Monte Carlo method, fitting of optical model parameters, extended set of optical ...
A variety of impacts are foreseen by implementing the 1985 IAEA regulations. The more significant regulation changes would require a reanalysis of release limits as a result of changes in the A{sub 1}/A{sub 2} table, analysis of the deep water submergence test and performance of a crush test for certain light weight packagings. Of ...
Pacific Northwest National Laboratory (PNNL) obtained a Mettler Toledo floor scale for the purpose of testing it to determine whether it can replace the International Atomic Energy Agency�s (IAEA) cumbersome, hanging load cell. The floor scale is intended for use as a subsystem within PNNL�s nascent UF6 Cylinder Portal Monitor. The particular model was ...
The Bulk-Assay Calorimeter described in ANL-NDA-9/ISPO-14 was field tested at the Belgonucleaire mixed-oxide fuel fabrication plant at Dessel, Belgium, May 13-19, 1982. This instrument was developed under ISPO Tasks A-9 and A-47 at Argonne National Laboratory and was supplied to the IAEA through the U.S support program. Five containers of plutonium-oxide ...
The sequence of events in the design, testing and fabrication of a radioisotopic heat source using available $sup 238$PuO$sub 2$ fuel that would be amenable to a Navy 0.5-W (electrical) Radioisotopic Thermoelectric Generator for undersea application is discussed. Various designs were considered as a function of heat leak in order to adopt the most desirable ...
The present work on fatigue-loading spectra encompasses the current status of standardized stress-time histories, European approaches to standard loading spectrum development, transport aircraft airframe fatigue test spectra, the TURBISTAN fatigue-loading standard for fighter-aircraft engine disks, an automated procedure for the ...
The modification of the well-known computer code for complex gamma -ray spectra processing KATOK is described. The changes carried out allowed one to accelerate processing of spectra by more than twice without reducing solution quality. The test examples ...
Comparison of measurements and calculations of fast neutron spectra from a radioactive neutron source inside spheres of Mo or Pb and from a cylindrical reactor containing a thick Pb or Mo reflector are used as a test of ENDF cross sections. The sphere lea...
It is likely that the ongoing process to produce the 1996 version of the IAEA Regulation for the Safe Transport of Radioactive Materials, IAEA Safety Series 6(SS 6) will result in a more stringent package qualification standard for air transport of large quantities of radioactive materials (RAM) than is included in the 1990 version. During the process to ...
The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive ...
This document is an overview of International Atomic Energy Agency (IAEA) safeguards and the basic requirements or elements of an IAEA safeguards regime. The primary objective of IAEA safeguards is the timely detection of the diversion of a significant quantity of material and the timely detection of undeclared activities. The two ...
... SPECTRA, CALIBRATION, ASSEMBLY, FOCAL PLANES, PIXELS, OPTICAL LENSES, ULTRAVIOLET DETECTORS, SPECTROGRAPHY, IMAGE ...
... OF STANDARDIZED SEQUENCES OF FLIGHT-BY-FLIGHT LOAD SPECTRA IN FATIGUE TESTING OF STRUCTURAL AIRCRAFT COMPONENTS ...
... Descriptors : *Patents, *Soybeans, *Food processing, Test methods, Fluorescence, Intensity, Excitation, Measuring instruments, Ultraviolet spectra ...
... CYANATES, STEAM, VOLUMETRIC ANALYSIS, ACCELERATED TESTING, INFRARED SPECTRA, FURANS, HYDROXYL RADICALS ...
... This test equipment is capable of programming slowly varying static loads, dynamic loads, and temperature, automatically through the use of ...
... FIELD TESTS, DATA ACQUISITION, BAND SPECTRA, WATER VAPOR, STABILITY, RADIATION, MEASUREMENT, PASSIVE SYSTEMS. ...