Standard Number: | 1910.1017 App A |
Title: | Supplemental medical information |
When required tests under paragraph (k)(1) of this section show abnormalities, the tests should be repeated as soon as practicable, preferably within 3 to 4 weeks. If tests remain abnormal, consideration should be given to withdrawal of the employee from contact with vinyl chloride, while a more comprehensive examination is made. Additional tests which may be useful: A. For kidney dysfunction: urine examination for albumin, red blood cells, and exfoliative abnormal cells. B. Pulmonary system: Forced vital capacity, Forced expiratory volume at 1 second, and chest roentgenogram (posterior-anterior, 14 X 17 inches). C. Additional serum tests: Lactic acid dehydrogenase, lactic acid dehydrogenase isoenzyme, protein determination, and protein electrophoresis. D. For a more comprehensive examination on repeated abnormal serum tests: Hepatitis B antigen, and liver scanning. [39 FR 35896, Oct. 4, 1974; 39 FR 41848, Dec. 3, 1974, as amended at 40 FR 13211, Mar. 25, 1975. Redesignated at 40 FR 23072, May 28, 1975 and amended at 43 FR 49751, Oct. 24, 1978; 45 FR 35282, May 23, 1980; 54 FR 24334, June 7. 1989; 61 FR 5507, Feb. 13, 1996] |