Security Levels

National Terrorism Advisory System (NTAS) check current status

Port Services

The Base Alameda Force Protection Officer (phone 510-437-3717) coordinates the functions of the Port Services Office.  The functions of the Port Services Office include assignment of berths, the use of piers, coordination of repairs by the NESU Alameda Industrial Activity, supplies and fuels, medical and human resource services, communication links and other services of a similar nature.

 

The Port Services Officer is located in the Base Alameda Security Office, Building 3.

Logistics Requests (LOGREQ)

Cutters expecting to moor at Base Alameda should notify Port Services of their intent as soon as practical.  Arriving cutters should submit a LOGREQ message not less that 3 days in advance of arrival.  The LOGREQ should be addressed to:
          COGARD INTSUPRTCOM ALAMEDA CA//fp//.
The visiting cutter should receive a LOGREQ reply no later than 48 hours before arrival.  If a LOGREQ reply is not received, call Base Alameda Port Services Officer or the OOD.

Relevant Navigational Information

Berths and Anchorages

Base Alameda - Pier Services

Pier Electrical: Power Mound (PM) & Service Water Sewage Air Draft Phone Service Cable Service
One PM 1: 2-400 amp, 480 volt Recept. / 120VAC Recept 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 28 ft 12 Lines 1 Line
One PM 2: 2-400 amp, 480 volt Recept. / 120VAC Recept. 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 28 ft 12 Lines 1 Line
Two PM 3: 2-400 amp, 480 volt Recept. / 120VAC Recept. 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 30 ft 12 Lines 1 Line
Two PM 4: 2-400 amp, 480 volt Recept. / 120VAC Recept 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 38 ft 12 Lines 1 Line
Three PM 5: 2-400 amp, 480 volt Recept. / 120VAC Recept. 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 38 ft 12 Lines 1 Line
Three PM 6: 2-400 amp, 480 volt Recept. / 120VAC Recept. 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 31 ft 12 Lines 1 Line
Four * PM 7: 2-400 amp, 480 volt Recept. / 120VAC Recept 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 18 ft 12 Lines 1 Line
Five * PM 7: 2-400 amp, 480 volt Recept. / 120VAC Recept 1-1/2" NPT 4" Female Cam-Lock 3/4" Quick Disconn. / 120 psi 18 ft 12 Lines 1 Line

*Pier 4 & 5 will only accept Cutters up to 87’ in length and 19.5’ beam

Download Plug-Ins
Download Plug-Ins: Some of the links on this page require a plug-in to view them. Links to the plug-ins are available below.
Click Here to Download Adobe Acrobat Reader Adobe Acrobat Reader (PDF)
Last Modified 7/11/2012