ENERGY STAR Building Design Profile

Seven Generations Office Park, Building A
Fort Collins, CO 80521

Seven Generations Office Park, Building A

The 10,000-square-foot Seven Generations Office Park, Building A located in Fort Collins, CO, was designed by RB+B Architects, Inc. to be an example of a building project that is both green and economical. Building owner Seven Generations, LLC believed in the possibility of offering high performance office space at the same cost as traditional office space, which would give it an edge in the marketplace and help spread the word that sustainable building practices help fight global warming and are economically feasible.

RB+B and Seven Generations chose to use EPA’s Target Finder in their overall approach because the tool is nationally recognized for helping design teams set realistic high energy performance goals. The design rated at 96 (out of 100) in Target Finder, thus achieving Designed to Earn the ENERGY STAR. Compared to an average office building with similar characteristics, Seven Generations Office Park, Building A is expected to use 56 percent less energy.

The project uses raised access floors for under-floor air distribution, which can be controlled by building occupants and is more efficient than traditional overhead air distribution. The building takes advantage of extensive daylighting strategies to decrease the need for electric light. Additional design strategies to reduce energy used by lighting include: energy-efficient windows, occupancy sensors in restrooms, and reduced exterior lighting power. Through careful placement of the insulation in the wall and roof assemblies and reduced air infiltration, the building’s high performance envelope reduces the heating and cooling loads and the size of the mechanical equipment needed. Efficient plumbing fixtures and draught-tolerant landscaping dramatically reduce water consumption. A small demonstration solar array further helps offset a portion of the building’s electricity usage.

Back to Architects & Projects

Designed to Earn the ENERGY STAR

Design Team

Architect of Record:
RB+B Architects, Inc
Fort Collins, CO

MEP Engineer:
Beaudin Ganze Consulting Engineers, Inc.
Lakewood, CO

Energy Analysis:
Enermodal Engineering, Inc.
Denver, CO

Building Owner:
Seven Generations, LLC
Fort Collins, CO

Design Rating / % Energy and CO₂ Reduction*:
96 / 56%

Design / Completion Date:
2008 / December 2007

Space Type:
Office

Floor Space:
10,000 sf

Estimated Energy Use Intensity:
98.4 kBtu/sf/yr

Estimated Total Annual Energy Use:
984,000 kBtu

Estimated Annual Energy Cost:
$5,000

Technologies Specified:
Under-floor air distribution, daylighting strategies, high performance building envelope and windows, occupancy sensors in restrooms, reduced exterior lighting power, efficient plumbing fixtures and draught-tolerant landscaping for reduced building and site water usage, and demonstration solar array.

For More Information:
Matt Arabasz
RB+B Architects, Inc.
212.627.1700
marabasz@rbbarchitects.com

*Percent Energy and CO₂ Reductions are compared with an average building of similar type.