FHWA > Engineering > Pavements > Concrete > Maintenance of Highway Edge drains |
Maintenance of Highway Edge drainsRobert H. Baumgardner Maintenance is required to keep pavement subsurface drainage open so that the pavement structure will drain. Just about all State highway agencies (SHA's) that have constructed subsurface drainage systems recognize that maintenance is a problem. Vegetative growth around the pipe outlets, rodent's nests, mowing clippings, and sediment collecting on rodent screens at headwall are common maintenance problems. Some outlets have been so plugged that water has gushed from the pipes when they were unplugged. The purpose of this paper is to identify maintenance problems with edgedrains and document FHWA attempts at stressing the importance of maintenance to SHA's. A description of the various maintenance problems encountered by SHA's follows. An example of vegetative material removed from an edgedrain is shown in Photo No. 1, while an edgedrain pipe blocked by a rodent's nest is shown in Photo No. 2. Photo No. 1 Vegetative Material Removed from an Edgedrain System Photo No. 2 Rodent's Nest Crushed pipe are shown in Photo No. 3 and 4. Most likely these pipe were crushed during construction. Photo No. 3 Crushed Pipe Photo No. 4 Crushed Pipe Often outlets cannot be found because they are hidden by vegetative growth. Photo No. 5 shows a typical hidden and crushed outlet. Note that there is no headwall. Photo No. 5 Hidden Outlet Pipe It is obvious that if maintenance personnel can not find the outlets, no maintenance can be performed. SHA's that use concrete headwalls, reference markers, signs on fences, reflector disks in the shoulder, or painted arrows on the shoulders have better success in providing maintenance. It is also important that maintenance activities not block or damage the pipe outlet. A simple arrow painted on the edge of the shoulder, as shown in Photo No. 6, is a good reference marker for maintenance personnel. Photo No. 6 Painted Arrow as a Reference Marker One of the purposes of a headwall is to eliminate erosion at the pipe outlet. Unfortunately, excessive erosion at an edgedrain outlet is shown below in Photo No. 7. Photo No. 7 Excessive Erosion at the Outlet Pipe Larger headwalls, as shown in Figure No.8 have the following advantages:
Photo No. 8 Large Outlet Pipe Headwall Video inspection of edgedrains has two important benefits for SHA's:
Photo No. 9 shows a section of edgedrain that has collapsed. This problem was identified by video inspection. Photo No. 9 Crushed Edgedrain Pipe In Photo No. 10, the video inspection camera is approaching the main line longitudinal edgedrain. It will be difficult for the camera to make this turn from the outlet pipe to the edgedrain. It will also be difficult for any cleaning equipment to make the turn. This is why FHWA recommends large radius pipe or a combination of bends to make the turn. Photo No. 10 Ninety Degree Tee If flexible corrugated plastic pipe has been used as an edgedrain, the pipe will not be perfectly straight since the pipe has a tendency to coil during the laying process. Any low points in the edgedrain provide an opportunity for sediment to build up. Periodic flushing of the edgedrain may be necessary to remove sediment build up. Flushing or jet rodding the system is important in the maintenance scheme. It is important that the pipe have proper bends to facilitate this operation. The edgedrain pipe system should be designed with maintenance in mind. These operations should be done on a routine schedule. A pipe flushing unit is shown in Photo No. 11. The water jets point towards the rear of the unit so that the jetting action helps to propel the unit through the pipe. Photo No. 11 Pipe Flushing Unit Edgedrain outlets and pipe systems should be inspected at least once a year to determine their condition. Use of video equipment to inspect the edgedrain pipe is recommended. Flushing of the pipe system should be performed as necessary. Maintenance personnel should mow around the outlet pipes at least twice a year. It is important to perform the mowing on a periodic basis to keep vegetative build up to a minimum. Roadside ditches should also be mowed and kept clean of debris. The need for maintenance was first expressed in Technical Paper No. 90-01 "Subsurface Pavement Drainage:"
This theme has been expressed in the following FHWA drainage efforts: Final Report, Experimental Project No. 12, "Effectiveness of Highway Edgedrains" Participant Notebook, Demonstration Project No. 87, "Drainable Pavement Systems" Final Report, "Video Inspection of Highway Edgedrain Systems" Reference Manual, NHI Course No. 131026A, "Pavement Subsurface Drainage Design" Reference Manual, Drainage Construction Workshops, "Construction of Pavement Subsurface Drainage Systems" FHWA's guidance in all of these efforts is the same: if a SHA is unwilling to make the necessary maintenance commitment, subsurface drainage systems should not be provided. Demonstration Project No. 87 (Demo 87) "Drainable Pavement Systems" Section 15.0 Maintenance of Demo 87 stresses the need for maintenance. The most important statement in this section follows: "If an SHA is unwilling to make a maintenance commitment, permeable bases should not be used since the pavement section will become flooded. This increases the rate of pavement damage." NHI Course 131026A, "Pavement Subsurface Drainage Design" Chapter 10, Maintenance, of the Reference Manual for the NHI Course No. 131026A, "Pavement Subsurface Drainage," provides an extensive discussion of maintenance problems. The manual lists the following problems for longitudinal edgedrains: "For permeable bases with longitudinal edgedrains:
Below is a list of problems associated with daylighted permeable bases: "For daylighted permeable bases:
The Reference Manual makes the following salient recommendations:
Two relatively recent NCHRP Synthesis provide excellent discussions on the need for maintenance. NCHRP Synthesis 239 "Pavement Subsurface Drainage Systems" NCHRP Synthesis 239, "Pavement Subsurface Drainage Systems" is an up date of the previous Synthesis 96 with the same title. One of the main contributions that this synthesis makes is the use of the team approach. The synthesis stresses the need for coordination and cooperation between planners, designers, construction personnel and maintenance people. While this concept is certainly not new, subsurface drainage is certainly an area where the team approach has merit. The cost effectiveness of drainage systems is recognized by the following conclusions:
The need for maintenance is recognized by the following conclusions:
NCHRP Synthesis 285 "Maintenance of Highway Edgedrains The new NCHRP Synthesis 285, "Maintenance of Highway Edgedrains," provides a very insightful look into the problems associated with edgedrain maintenance. This synthesis is an extension of Synthesis 239 in which the need for maintenance was stressed. The conclusions listed below are extremely important since they hit at the heart of the problem. In the area of pavement performance and benefits, the synthesis draws the following conclusions:
The merits of pavement subsurface drainage are recognized by the following conclusion: "Based on the results of NCHRP Synthesis 239 and confirmed by literature reviewed in this synthesis, there is a significant cost in terms of poor pavement performance to agencies that are not using edge drains." The need for quality control in construction is acknowledged by the following conclusions:
The need for qualified and trained maintenance personnel is seen in the following conclusion: "All maintenance personnel should be made aware that a plugged subsurface drainage system may be worse than no drainage system because the pavement system becomes permanently saturated." Two of the most scathing conclusions were:
Summary If a SHA is unwilling to make a maintenance commitment, permeable bases should not be used since the pavement section will become flooded. This will increase the rate of pavement damage (FHWA 1992, Christopher 1997). REFERENCES
PDF files can be viewed with the Acrobat® Reader®
|
||
Updated: 04/07/2011 |