Millstone 2
2Q/2012 Performance Indicators
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Unplanned scrams | 0 | 1.0 | 0 | 1.0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2134.5 | 2159.0 | 1408.9 | 1879.7 | 2209.0 | 2183.0 | 2184.0 |
Indicator value | 1.8 | 2.4 | 1.6 | 1.8 | 1.8 | 0.9 | 0.9 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Unplanned power changes | 0 | 1.0 | 0 | 0 | 2.0 | 0 | 1.0 | 0 |
Critical hours | 2208.0 | 2134.5 | 2159.0 | 1408.9 | 1879.7 | 2209.0 | 2183.0 | 2184.0 |
Indicator value | 0.9 | 0.8 | 0.8 | 0.9 | 2.8 | 1.8 | 2.7 | 2.5 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 1.0 | 1.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Safety System Functional Failures | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 0 |
Indicator value | 2 | 1 | 0 | 1 | 1 | 1 | 2 | 1 |
Licensee Comments:
2Q/11: LER 2011-001-00
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | 2.25E-07 | 1.58E-07 | 1.31E-07 | 4.11E-08 | 4.14E-08 | 3.20E-08 | 2.02E-08 | 4.15E-08 |
URI (ΔCDF) | 4.61E-09 | 3.00E-09 | 4.77E-10 | 7.10E-08 | 6.92E-08 | -1.55E-07 | -1.55E-07 | -1.52E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 2.30E-07 | 1.60E-07 | 1.30E-07 | 1.10E-07 | 1.10E-07 | -1.20E-07 | -1.30E-07 | -1.10E-07 |
Licensee Comments:
2Q/12: A condition report on the diesel was written on 6/29/12. This condition report is under review. If this event is determined to be a failure the 2nd quarter values will be updated in the 3rd quarter.
2Q/11: A PRA model change for Millstone Unit 2 was implemented during the second quarter.
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | -2.73E-07 | -2.73E-07 | -2.73E-07 | -6.36E-08 | -6.36E-08 | -6.36E-08 | -6.36E-08 | -6.36E-08 |
URI (ΔCDF) | -3.95E-08 | 1.17E-07 | 1.17E-07 | 1.48E-07 | 1.48E-07 | 1.46E-07 | 1.46E-07 | 1.44E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.10E-07 | -1.60E-07 | -1.60E-07 | 8.40E-08 | 8.40E-08 | 8.30E-08 | 8.20E-08 | 8.00E-08 |
Licensee Comments:
2Q/11: A PRA model change for Millstone Unit 2 was implemented during the second quarter.
Mitigating Systems Performance Index, Heat Removal System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | -4.49E-08 | -4.30E-08 | -4.26E-08 | -4.63E-08 | -4.17E-08 | -7.48E-08 | -6.15E-08 | -8.75E-08 |
URI (ΔCDF) | -1.46E-07 | -1.50E-07 | -1.50E-07 | -1.33E-07 | -1.38E-07 | -1.36E-07 | -1.37E-07 | -1.38E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.90E-07 | -1.90E-07 | -1.90E-07 | -1.80E-07 | -1.80E-07 | -2.10E-07 | -2.00E-07 | -2.30E-07 |
Licensee Comments:
2Q/11: A PRA model change for Millstone Unit 2 was implemented during the second quarter.
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | -4.57E-10 | -4.58E-10 | -6.64E-10 | -2.08E-10 | -1.82E-10 | -1.95E-10 | -1.95E-10 | -1.98E-10 |
URI (ΔCDF) | -1.53E-08 | -1.53E-08 | -1.55E-08 | -1.32E-08 | -1.31E-08 | -1.33E-08 | -1.35E-08 | -1.36E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.60E-08 | -1.60E-08 | -1.60E-08 | -1.30E-08 | -1.30E-08 | -1.30E-08 | -1.40E-08 | -1.40E-08 |
Licensee Comments:
2Q/11: A PRA model change for Millstone Unit 2 was implemented during the second quarter.
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
UAI (ΔCDF) | -2.75E-08 | -3.61E-08 | -3.61E-08 | -1.40E-09 | 5.34E-09 | 5.34E-09 | 5.33E-09 | 5.05E-09 |
URI (ΔCDF) | 1.99E-07 | -1.98E-07 | -1.99E-07 | -6.20E-08 | -6.28E-08 | -6.35E-08 | -6.42E-08 | -6.42E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.70E-07 | -2.30E-07 | -2.40E-07 | -6.30E-08 | -5.70E-08 | -5.80E-08 | -5.90E-08 | -5.90E-08 |
Licensee Comments:
2Q/11: A PRA model change for Millstone Unit 2 was implemented during the second quarter.
1Q/11: Changed PRA Parameter(s).
Reactor Coolant System Activity | 7/10 | 8/10 | 9/10 | 10/10 | 11/10 | 12/10 | 1/11 | 2/11 | 3/11 | 4/11 | 5/11 | 6/11 |
Maximum activity | 0.001580 | 0.001630 | 0.001710 | 0.001730 | 0.002030 | 0.001930 | 0.002020 | 0.002020 | 0.002460 | 0.002130 | 0.000863 | 0.000989 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.1 | 0.1 |
Reactor Coolant System Activity | 7/11 | 8/11 | 9/11 | 10/11 | 11/11 | 12/11 | 1/12 | 2/12 | 3/12 | 4/12 | 5/12 | 6/12 |
Maximum activity | 0.001300 | 0.001040 | 0.001040 | 0.001140 | 0.001210 | 0.001210 | 0.001250 | 0.001320 | 0.001450 | 0.001420 | 0.001430 | 0.001540 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 |
Licensee Comments: none
Reactor Coolant System Leakage | 7/10 | 8/10 | 9/10 | 10/10 | 11/10 | 12/10 | 1/11 | 2/11 | 3/11 | 4/11 | 5/11 | 6/11 |
Maximum leakage | 0.047 | 0.006 | 0.027 | 0.018 | 0.056 | 0.009 | 0.014 | 0.005 | 0.022 | 0 | 0.033 | 0.002 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.5 | 0.1 | 0.3 | 0.2 | 0.6 | 0.1 | 0.1 | 0.1 | 0.2 | 0 | 0.3 | 0 |
Reactor Coolant System Leakage | 7/11 | 8/11 | 9/11 | 10/11 | 11/11 | 12/11 | 1/12 | 2/12 | 3/12 | 4/12 | 5/12 | 6/12 |
Maximum leakage | 0.013 | 0.028 | 0.054 | 0.180 | 0.037 | 0.021 | 0.055 | 0.045 | 0.031 | 0.061 | 0.034 | 0.060 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.1 | 0.3 | 0.5 | 1.8 | 0.4 | 0.2 | 0.6 | 0.5 | 0.3 | 0.6 | 0.3 | 0.6 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Successful opportunities | 24.0 | 41.0 | 31.0 | 41.0 | 43.0 | 27.0 | 34.0 | 32.0 |
Total opportunities | 25.0 | 43.0 | 31.0 | 44.0 | 43.0 | 27.0 | 34.0 | 32.0 |
Indicator value | 96.0% | 95.9% | 96.9% | 96.2% | 96.4% | 96.7% | 97.2% | 97.8% |
Licensee Comments: none
ERO Drill Participation | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Participating Key personnel | 138.0 | 138.0 | 138.0 | 137.0 | 139.0 | 137.0 | 138.0 | 133.0 |
Total Key personnel | 138.0 | 138.0 | 138.0 | 137.0 | 139.0 | 137.0 | 138.0 | 133.0 |
Indicator value | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
Successful siren-tests | 473 | 553 | 474 | 553 | 474 | 553 | 474 | 473 |
Total sirens-tests | 474 | 553 | 474 | 553 | 474 | 553 | 474 | 474 |
Indicator value | 98.8% | 99.2% | 99.6% | 100.0% | 100.0% | 100.0% | 100.0% | 99.9% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/10 | 4Q/10 | 1Q/11 | 2Q/11 | 3Q/11 | 4Q/11 | 1Q/12 | 2Q/12 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Although the Security Cornerstone is included in the Reactor Oversight Process assessment program, the Commission has decided that specific information related to findings and performance indicators pertaining to the Security Cornerstone will not be publicly available to ensure that security information is not provided to a possible adversary. Other than the fact that a finding or performance indicator is Green or Greater-Than-Green, security related information will not be displayed on the public web page.
Action Matrix Summary |
Inspection Findings Summary |
PI Summary |
Reactor Oversight Process
Last Modified: July 24, 2012