ROP Action Matrix Summary and Current Regulatory Oversight
Action Matrix assessments for some plants will appear different on this Web page now that the NRC has reintegrated security inspection results into the agency’s ROP assessment program. These security findings were previously identified under the separate security assessment program. As such they represent existing performance issues that have not been shown on the public Action Matrix for these plants until now. Future updates to the Action Matrix will reflect new safety and security findings. |
The assessment program collects information from inspections and performance indicators (PIs) in order to enable the agency to arrive at objective conclusions about the licensee's safety performance. Based on this assessment information, the NRC determines the appropriate level of agency response, including supplemental inspection and pertinent regulatory actions ranging from management meetings up to and including orders for plant shutdown. The Action Matrix Summary listed below reflects overall plant performance and is updated regularly to reflect inputs from the most recent performance indicators and inspection findings. Although the Security Cornerstone is included in the Reactor Oversight Process assessment program, the Commission has decided that specific information related to findings and performance indicators pertaining to the Security Cornerstone will not be publicly available to ensure that security information is not provided to a possible adversary. Other than the fact that a finding or performance indicator is Green or Greater-Than-Green, security related information will not be displayed on the public web page.
For those plants that are in the Regulatory Response Column, Degraded Cornerstone Column, Multiple/Repetitive Degraded Cornerstone Column, and Unacceptable Performance Column of the Action Matrix, notes are provided to explain the assessment inputs that direct the associated regulatory response. Additionally, information on the current level of inspection at each reactor unit (based on deviations from the Action Matrix, supplemental inspection status, etc.) is also found below. For any licensee in the Licensee Response Column, the expected agency inspection is the baseline program.
The substantive cross-cutting issues are available on the ROP Substantive Cross Cutting Issues Summary page for each of the plants.
Last Modified: 09-05-2012
Current Regulatory Oversight Table
Region I | Region II | Region III | Region IV | Action Matrix Summary
 Region I
Reactor Unit Action Matrix Column Current Regulatory Oversight
Beaver Valley 1
Licensee Response Column
Baseline inspection
Beaver Valley 2
Licensee Response Column
Baseline inspection
Calvert Cliffs 1
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Calvert 1 is in Column 1.
Baseline inspection
Calvert Cliffs 2
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Calvert 2 is in Column 1.
Baseline inspection
FitzPatrick
Licensee Response Column
Baseline inspection
Ginna
Licensee Response Column
Baseline inspection
Hope Creek 1
Degraded Cornerstone Column
Hope Creek is in Column 3 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 1Q2012.
Baseline inspection
and
IP 95002 supplemental inspection
Indian Point 2
Licensee Response Column
Baseline inspection
Indian Point 3
Licensee Response Column
Baseline inspection
Limerick 1
Licensee Response Column
Baseline inspection
Limerick 2
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Mitigating Systems Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Limerick 2 is in Column 1.
Baseline inspection
Millstone 2
Regulatory Response Column
Millstone 2 is in Column 2 because of a white finding in the Initiating Events Cornerstone originating in 2Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Millstone 3
Licensee Response Column
Baseline inspection
Nine Mile Point 1
Licensee Response Column
Baseline inspection
Nine Mile Point 2
Licensee Response Column
Baseline inspection
Oyster Creek
Licensee Response Column
Baseline inspection
Peach Bottom 2
Licensee Response Column
Baseline inspection
Peach Bottom 3
Licensee Response Column
Baseline inspection
Pilgrim 1
Regulatory Response Column
Pilgrim 1 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 3Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Salem 1
Degraded Cornerstone Column
Salem 1 is in Column 3 because of one or more greater-than-green finding(s) in the Security Systems Cornerstone originating in 1Q2012.
Baseline inspection
and
IP 95002 supplemental inspection
Salem 2
Degraded Cornerstone Column
Salem 2 is in Column 3 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 1Q2012.
Baseline inspection
and
IP 95002 supplemental inspection
Seabrook 1
Regulatory Response Column
Seabrook 1 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Susquehanna 1
Regulatory Response Column
Susquehanna 1 is in Column 2 because of one white finding in the Initiating Events Cornerstone originating in 3Q2010. A prior 95002 was performed because Susquehanna 1 was in Column 3 (see report ML12125A374). The inspection found that the white finding was not adequately addressed. Therefore, the finding will be held open until it is inspected satisfactorily. Note that the White Performance Indicator (Unplanned Scrams per 7000 Critical Hours) associated with Column 3 was closed during the 95002 inspection.
Baseline inspection
and
Continuation of IP 95002 supplemental inspection to address remaining white finding
Susquehanna 2
Licensee Response Column
Baseline inspection
Three Mile Island 1
Licensee Response Column
Baseline inspection
Vermont Yankee
Licensee Response Column
Baseline inspection
 Region II
Reactor Unit Action Matrix Column Current Regulatory Oversight
Browns Ferry 1
Multiple/Repetitive Degraded Cornerstone Column
Browns Ferry 1 is in Column 4 because of a red finding in the Mitigating Systems Cornerstone originating in 4Q2010.
Baseline inspection
and
IP 95003 supplemental inspection
Browns Ferry 2
Regulatory Response Column
Browns Ferry 2 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Browns Ferry 3
Regulatory Response Column
Browns Ferry 3 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 2Q2012. Browns Ferry Unit 3 also has one white PI in the Initiating Events Cornerstone, Unplanned Scrams per 7000 Critical Hours, originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Brunswick 1
Regulatory Response Column
Brunswick 1 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Brunswick 2
Regulatory Response Column
Brunswick 1 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Catawba 1
Licensee Response Column
Baseline inspection
Catawba 2
Licensee Response Column
Baseline inspection
Crystal River 3
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Emergency Preparedness Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Crystal River is in Column 1.
Baseline inspection
Farley 1
Regulatory Response Column
Farley 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Farley 2
Regulatory Response Column
Farley 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Harris 1
Licensee Response Column
Baseline inspection
Hatch 1
Licensee Response Column
Baseline inspection
Hatch 2
Licensee Response Column
Baseline inspection
McGuire 1
Licensee Response Column
Baseline inspection
McGuire 2
Licensee Response Column
Baseline inspection
North Anna 1
Regulatory Response Column
North Anna 1 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
North Anna 2
Regulatory Response Column
North Anna 2 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Oconee 1
Licensee Response Column
As detailed in the inspection report 2012011 (ML12068A353) Oconee 1 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection.
Baseline inspection
and
IP 95002 supplemental inspection
Oconee 2
Licensee Response Column
As detailed in the inspection report 2012011 (ML12068A353) Oconee 2 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection.
Baseline inspection
and
IP 95002 supplemental inspection
Oconee 3
Licensee Response Column
As detailed in the inspection report 2012011 (ML12068A353) Oconee 3 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection.
Baseline inspection
and
IP 95002 supplemental inspection
Robinson 2
Licensee Response Column
Baseline inspection
Saint Lucie 1
Degraded Cornerstone Column
Saint Lucie 1 is in Column 3 because of two white Initiating Events Cornerstone PIs both originating in 1Q2012.
Baseline inspection
and
IP 95002 supplemental inspection
Saint Lucie 2
Licensee Response Column
Baseline inspection
Sequoyah 1
Licensee Response Column
Baseline inspection
Sequoyah 2
Licensee Response Column
Baseline inspection
Summer
Licensee Response Column
Baseline inspection
Surry 1
Licensee Response Column
Baseline inspection
Surry 2
Licensee Response Column
Baseline inspection
Turkey Point 3
Regulatory Response Column
Turkey Point Unit 3 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Turkey Point 4
Regulatory Response Column
Turkey Point Unit 4 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Vogtle 1
Licensee Response Column
Baseline inspection
Vogtle 2
Licensee Response Column
Baseline inspection
Watts Bar 1
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Watts Bar is in Column 1.
Baseline inspection
 Region III
Reactor Unit Action Matrix Column Current Regulatory Oversight
Braidwood 1
Licensee Response Column
Baseline inspection
Braidwood 2
Regulatory Response Column
Braidwood 2 is in Column 2 because of one white PI in the Mitigating Systems Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Byron 1
Licensee Response Column
Baseline inspection
Byron 2
Licensee Response Column
Baseline inspection
Clinton
Licensee Response Column
Baseline inspection
D.C. Cook 1
Licensee Response Column
Baseline inspection
D.C. Cook 2
Licensee Response Column
Baseline inspection
Davis-Besse
Licensee Response Column
Baseline inspection
Dresden 2
Licensee Response Column
Baseline inspection
Dresden 3
Licensee Response Column
Baseline inspection
Duane Arnold
Licensee Response Column
Baseline inspection
Fermi 2
Regulatory Response Column
Fermi is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2010.
Baseline inspection
and
IP 95001 supplemental inspection
Kewaunee
Licensee Response Column
Baseline inspection
La Salle 1
Licensee Response Column
Baseline inspection
La Salle 2
Licensee Response Column
Baseline inspection
Monticello
Licensee Response Column
Baseline inspection
Palisades
Degraded Cornerstone Column
Palisades is in Column 3 because of a yellow finding in the Initiating Events Cornerstone originating in 4Q2011. Palisades also has a white finding in the Initiating Events Cornerstone and a white finding in the Mitigating Systems Cornerstone, both originating 4Q2011.
Baseline inspection
and
IP 95002 supplemental inspection
Perry 1
Degraded Cornerstone Column
Perry 1 is in Column 3 because of one white Occupational Radiation Safety Cornerstone PI and one white finding in the Occupational Radiation Safety Cornerstone both originating in 2Q2011.
Baseline inspection
and
IP 95002 supplemental inspection
Point Beach 1
Regulatory Response Column
Point Beach 1 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Point Beach 2
Regulatory Response Column
Point Beach 2 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
Prairie Island 1
Regulatory Response Column
Prairie Island 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Prairie Island 2
Regulatory Response Column
Prairie Island 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Quad Cities 1
Licensee Response Column
Baseline inspection
Quad Cities 2
Licensee Response Column
Baseline inspection
 Region IV
Reactor Unit Action Matrix Column Current Regulatory Oversight
Arkansas Nuclear 1
Licensee Response Column
Baseline inspection
Arkansas Nuclear 2
Licensee Response Column
Baseline inspection
Callaway
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Callaway is in Column 1.
Baseline inspection
Columbia Generating Station
Licensee Response Column
Baseline inspection
Comanche Peak 1
Licensee Response Column
Baseline inspection
Comanche Peak 2
Licensee Response Column
Baseline inspection
Cooper
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary still indicates a white inspection finding under the Mitigating Systems Cornerstone. The supplemental inspection was performed satisfactorily. As of 1Q2012, the finding is closed and Cooper is in Column 1.
Baseline inspection
Diablo Canyon 1
Licensee Response Column
Baseline inspection
Diablo Canyon 2
Licensee Response Column
Baseline inspection
Fort Calhoun
Under IMC 0350
Fort Calhoun is under the oversight of inspection manual chapter 0350, "Oversight of Reactor Facilities in a Shutdown Condition due to Significant Performance and/or Operational Concerns." For more information please see the letter dated December 13, 2011 (ML113470721).
Nuclear Regulatory Commission staff has established a special oversight panel to coordinate the agency's regulatory activities associated with assessing the performance issues at Fort Calhoun.
Grand Gulf 1
Licensee Response Column
Baseline inspection
Palo Verde 1
Regulatory Response Column
Palo Verde 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Palo Verde 2
Regulatory Response Column
Palo Verde 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
Palo Verde 3
Regulatory Response Column
Palo Verde 3 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011.
Baseline inspection
and
IP 95001 supplemental inspection
River Bend 1
Regulatory Response Column
River Bend is in Column 2 because of one white PI in the Initiating Events Cornerstone for Unplanned Scrams with Complications originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
San Onofre 2
Regulatory Response Column
San Onofre 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
San Onofre 3
Regulatory Response Column
San Onofre 3 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
South Texas 1
Licensee Response Column
Baseline inspection
South Texas 2
Licensee Response Column
Baseline inspection
Waterford 3
Licensee Response Column
The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Occupational Radiation Safety Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Waterford is in Column 1.
Baseline inspection
Wolf Creek 1
Regulatory Response Column
Wolf Creek is in Column 2 because of a white PI in the Mitigating Systems Cornerstone originating in 2Q2012.
Baseline inspection
and
IP 95001 supplemental inspection
  Action Matrix Summary
Top of Page
Last modification: Sep 05, 2012
Current Regulatory Oversight Table
Region I | Region II | Region III | Region IV | Action Matrix Summary
 Region I
Reactor Unit | Action Matrix Column | Current Regulatory Oversight |
Beaver Valley 1 | Licensee Response Column | Baseline inspection |
Beaver Valley 2 | Licensee Response Column | Baseline inspection |
Calvert Cliffs 1 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Calvert 1 is in Column 1. |
Baseline inspection |
Calvert Cliffs 2 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Calvert 2 is in Column 1. |
Baseline inspection |
FitzPatrick | Licensee Response Column | Baseline inspection |
Ginna | Licensee Response Column |
Baseline inspection |
Hope Creek 1 | Degraded Cornerstone Column Hope Creek is in Column 3 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 1Q2012. |
Baseline inspection and IP 95002 supplemental inspection |
Indian Point 2 | Licensee Response Column | Baseline inspection |
Indian Point 3 | Licensee Response Column | Baseline inspection |
Limerick 1 | Licensee Response Column | Baseline inspection |
Limerick 2 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Mitigating Systems Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Limerick 2 is in Column 1. |
Baseline inspection |
Millstone 2 | Regulatory Response Column Millstone 2 is in Column 2 because of a white finding in the Initiating Events Cornerstone originating in 2Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Millstone 3 | Licensee Response Column | Baseline inspection |
Nine Mile Point 1 | Licensee Response Column | Baseline inspection |
Nine Mile Point 2 | Licensee Response Column | Baseline inspection |
Oyster Creek | Licensee Response Column | Baseline inspection |
Peach Bottom 2 | Licensee Response Column | Baseline inspection |
Peach Bottom 3 | Licensee Response Column | Baseline inspection |
Pilgrim 1 | Regulatory Response Column Pilgrim 1 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 3Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Salem 1 | Degraded Cornerstone Column Salem 1 is in Column 3 because of one or more greater-than-green finding(s) in the Security Systems Cornerstone originating in 1Q2012. |
Baseline inspection and IP 95002 supplemental inspection |
Salem 2 | Degraded Cornerstone Column Salem 2 is in Column 3 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 1Q2012. |
Baseline inspection and IP 95002 supplemental inspection |
Seabrook 1 | Regulatory Response Column Seabrook 1 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Susquehanna 1 | Regulatory Response Column Susquehanna 1 is in Column 2 because of one white finding in the Initiating Events Cornerstone originating in 3Q2010. A prior 95002 was performed because Susquehanna 1 was in Column 3 (see report ML12125A374). The inspection found that the white finding was not adequately addressed. Therefore, the finding will be held open until it is inspected satisfactorily. Note that the White Performance Indicator (Unplanned Scrams per 7000 Critical Hours) associated with Column 3 was closed during the 95002 inspection. |
Baseline inspection and Continuation of IP 95002 supplemental inspection to address remaining white finding |
Susquehanna 2 | Licensee Response Column | Baseline inspection |
Three Mile Island 1 | Licensee Response Column | Baseline inspection |
Vermont Yankee | Licensee Response Column | Baseline inspection |
 Region II
Reactor Unit | Action Matrix Column | Current Regulatory Oversight |
Browns Ferry 1 | Multiple/Repetitive Degraded Cornerstone Column Browns Ferry 1 is in Column 4 because of a red finding in the Mitigating Systems Cornerstone originating in 4Q2010. |
Baseline inspection and IP 95003 supplemental inspection |
Browns Ferry 2 | Regulatory Response Column Browns Ferry 2 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Browns Ferry 3 | Regulatory Response Column Browns Ferry 3 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 2Q2012. Browns Ferry Unit 3 also has one white PI in the Initiating Events Cornerstone, Unplanned Scrams per 7000 Critical Hours, originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Brunswick 1 | Regulatory Response Column Brunswick 1 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Brunswick 2 | Regulatory Response Column Brunswick 1 is in Column 2 because of a white finding in the Mitigating Systems Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Catawba 1 | Licensee Response Column | Baseline inspection |
Catawba 2 | Licensee Response Column | Baseline inspection |
Crystal River 3 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Emergency Preparedness Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Crystal River is in Column 1. |
Baseline inspection |
Farley 1 | Regulatory Response Column Farley 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Farley 2 | Regulatory Response Column Farley 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Harris 1 | Licensee Response Column | Baseline inspection |
Hatch 1 | Licensee Response Column | Baseline inspection |
Hatch 2 | Licensee Response Column | Baseline inspection |
McGuire 1 | Licensee Response Column | Baseline inspection |
McGuire 2 | Licensee Response Column | Baseline inspection |
North Anna 1 | Regulatory Response Column North Anna 1 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
North Anna 2 | Regulatory Response Column North Anna 2 is in Column 2 because of one white finding in the Mitigating Systems Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Oconee 1 | Licensee Response Column As detailed in the inspection report 2012011 (ML12068A353) Oconee 1 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection. |
Baseline inspection and IP 95002 supplemental inspection |
Oconee 2 | Licensee Response Column As detailed in the inspection report 2012011 (ML12068A353) Oconee 2 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection. |
Baseline inspection and IP 95002 supplemental inspection |
Oconee 3 | Licensee Response Column As detailed in the inspection report 2012011 (ML12068A353) Oconee 3 has a yellow inspection finding in the Mitigating Systems Cornerstone. This finding was determined to be an old design issue, and in accordance with IMC 0305, will not aggregate in the Action Matrix with other performance indicators and inspection findings. Although the yellow finding will not aggregate in the Action Matrix, it will remain open until all IP 95002 inspection objectives have been met and verified by inspection. |
Baseline inspection and IP 95002 supplemental inspection |
Robinson 2 | Licensee Response Column |
Baseline inspection |
Saint Lucie 1 | Degraded Cornerstone Column Saint Lucie 1 is in Column 3 because of two white Initiating Events Cornerstone PIs both originating in 1Q2012. |
Baseline inspection and IP 95002 supplemental inspection |
Saint Lucie 2 | Licensee Response Column | Baseline inspection |
Sequoyah 1 | Licensee Response Column |
Baseline inspection |
Sequoyah 2 | Licensee Response Column | Baseline inspection |
Summer | Licensee Response Column | Baseline inspection |
Surry 1 | Licensee Response Column | Baseline inspection |
Surry 2 | Licensee Response Column | Baseline inspection |
Turkey Point 3 | Regulatory Response Column Turkey Point Unit 3 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Turkey Point 4 | Regulatory Response Column Turkey Point Unit 4 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Vogtle 1 | Licensee Response Column | Baseline inspection |
Vogtle 2 | Licensee Response Column | Baseline inspection |
Watts Bar 1 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Watts Bar is in Column 1. |
Baseline inspection |
 Region III
Reactor Unit | Action Matrix Column | Current Regulatory Oversight |
Braidwood 1 | Licensee Response Column | Baseline inspection |
Braidwood 2 | Regulatory Response Column Braidwood 2 is in Column 2 because of one white PI in the Mitigating Systems Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Byron 1 | Licensee Response Column | Baseline inspection |
Byron 2 | Licensee Response Column |
Baseline inspection |
Clinton | Licensee Response Column | Baseline inspection |
D.C. Cook 1 | Licensee Response Column | Baseline inspection |
D.C. Cook 2 | Licensee Response Column | Baseline inspection |
Davis-Besse | Licensee Response Column | Baseline inspection |
Dresden 2 | Licensee Response Column | Baseline inspection |
Dresden 3 | Licensee Response Column | Baseline inspection |
Duane Arnold | Licensee Response Column | Baseline inspection |
Fermi 2 | Regulatory Response Column Fermi is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2010. |
Baseline inspection and IP 95001 supplemental inspection |
Kewaunee | Licensee Response Column | Baseline inspection |
La Salle 1 | Licensee Response Column | Baseline inspection |
La Salle 2 | Licensee Response Column | Baseline inspection |
Monticello | Licensee Response Column | Baseline inspection |
Palisades | Degraded Cornerstone Column Palisades is in Column 3 because of a yellow finding in the Initiating Events Cornerstone originating in 4Q2011. Palisades also has a white finding in the Initiating Events Cornerstone and a white finding in the Mitigating Systems Cornerstone, both originating 4Q2011. |
Baseline inspection and IP 95002 supplemental inspection |
Perry 1 | Degraded Cornerstone Column Perry 1 is in Column 3 because of one white Occupational Radiation Safety Cornerstone PI and one white finding in the Occupational Radiation Safety Cornerstone both originating in 2Q2011. |
Baseline inspection and IP 95002 supplemental inspection |
Point Beach 1 | Regulatory Response Column Point Beach 1 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Point Beach 2 | Regulatory Response Column Point Beach 2 is in Column 2 because of a white finding in the Emergency Preparedness Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
Prairie Island 1 | Regulatory Response Column Prairie Island 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Prairie Island 2 | Regulatory Response Column Prairie Island 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Quad Cities 1 | Licensee Response Column | Baseline inspection |
Quad Cities 2 | Licensee Response Column | Baseline inspection |
 Region IV
Reactor Unit | Action Matrix Column | Current Regulatory Oversight |
Arkansas Nuclear 1 | Licensee Response Column | Baseline inspection |
Arkansas Nuclear 2 | Licensee Response Column | Baseline inspection |
Callaway | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a greater-than-green finding under the Security Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Callaway is in Column 1. |
Baseline inspection |
Columbia Generating Station | Licensee Response Column | Baseline inspection |
Comanche Peak 1 | Licensee Response Column | Baseline inspection |
Comanche Peak 2 | Licensee Response Column | Baseline inspection |
Cooper | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary still indicates a white inspection finding under the Mitigating Systems Cornerstone. The supplemental inspection was performed satisfactorily. As of 1Q2012, the finding is closed and Cooper is in Column 1. |
Baseline inspection |
Diablo Canyon 1 | Licensee Response Column | Baseline inspection |
Diablo Canyon 2 | Licensee Response Column | Baseline inspection |
Fort Calhoun | Under IMC 0350 Fort Calhoun is under the oversight of inspection manual chapter 0350, "Oversight of Reactor Facilities in a Shutdown Condition due to Significant Performance and/or Operational Concerns." For more information please see the letter dated December 13, 2011 (ML113470721). |
Nuclear Regulatory Commission staff has established a special oversight panel to coordinate the agency's regulatory activities associated with assessing the performance issues at Fort Calhoun. |
Grand Gulf 1 | Licensee Response Column | Baseline inspection |
Palo Verde 1 | Regulatory Response Column Palo Verde 1 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Palo Verde 2 | Regulatory Response Column Palo Verde 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
Palo Verde 3 | Regulatory Response Column Palo Verde 3 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 4Q2011. |
Baseline inspection and IP 95001 supplemental inspection |
River Bend 1 | Regulatory Response Column River Bend is in Column 2 because of one white PI in the Initiating Events Cornerstone for Unplanned Scrams with Complications originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
San Onofre 2 | Regulatory Response Column San Onofre 2 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
San Onofre 3 | Regulatory Response Column San Onofre 3 is in Column 2 because of one or more greater-than-green finding(s) in the Security Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
South Texas 1 | Licensee Response Column | Baseline inspection |
South Texas 2 | Licensee Response Column | Baseline inspection |
Waterford 3 | Licensee Response Column The Inspection Findings Summary and Unit Performance Summary pages indicate a white inspection finding under the Occupational Radiation Safety Cornerstone. The supplemental inspection was performed satisfactorily. As of 3Q2012, the finding is closed and Waterford is in Column 1. |
Baseline inspection |
Wolf Creek 1 | Regulatory Response Column Wolf Creek is in Column 2 because of a white PI in the Mitigating Systems Cornerstone originating in 2Q2012. |
Baseline inspection and IP 95001 supplemental inspection |
  Action Matrix Summary
Top of Page
Last modification: Sep 05, 2012