OSHA INSTRUCTION STD 3-10.4 OCTOBER 30, 1978
OSHA PROGRAM DIRECTIVE #100-84
TO: REGIONAL ADMINISTRATORS/OSHA
THRU: DONALD E. MACKENZIE Field Coordinator
Subject: 29 CFR 1926.451, Scaffolding
1. Purpose
The purpose of this directive is to clarify the application of 29
CFR 1926.451, Scaffolding, Construction standards.
2. Documentation Affected
This directive supersedes Field Information Memorandum #75-19 dated
March 6, 1975.
3. Background
As the result of a request to clarify the application of 29 CFR
1926.451, the following is herewith forwarded:
a. 29 CFR 1926.451(a)(2)--Concrete block is not always an
"unstable object" when used as a base for scaffolding. The circumstances and
techniques under which it is used must be considered to determine its
stability.
b. 29 CFR 1926.451(a)(3)--A brace is defined in 29 CFR 1926.452
(b)(3) as a tie that holds one scaffold member in a fixed position with
respect to another member. The fact that a scaffold member has a place for a
brace does not necessarily require that the brace be in place, if it
interferes with the erection or stocking of the scaffold. This is only true
if the scaffolding is capable of supporting four times the maximum intended
load and meets the other applicable requirements of 29 CFR 1926.451. Also,
the manufacturer's design specifications, particularly with respect to the
lateral stresses involved, are an important aspect which must be considered
in the decision to remove pieces of bracing.
-2-
OSHA INSTRUCTION STD 3-10.4 OCTOBER 30, 1978
c. 29 CFR 1926.451(a)(7) and (8)--A scaffold plank is considered a
component of the scaffolding. As such, it must e capable of supporting four
times the maximum intended load without failure (a safety factor of four).
The fact that a plank might have a split in one end does not automatically
mean that it must be removed from service, provided it does not otherwise
create a hazard to the employees.
d. 29 CFR 1926.451(d)(4)--The standard requires scaffold legs to
be placed on a foundation that is adequate to support four times the intended
load of the scaffold. The standard does not require that base plates always
be employed, but only when conditions necessitate their use. For example,
the scaffold legs cannot be placed on a mud foundation without a base to
prevent the legs from sinking into the mud.
4. Action
As in all cases, the determination of compliance or noncompliance
depends upon the conditions the CSHO observes at the time of inspection.
These four interpretations are meant as guidelines only.
5. Effective Date
This directive is effective immediately and will remain in effect
until canceled or superseded.