NIOSHTIC-2 No. 20030288


Instrumentation for Diesel Particulate Matter Emissions Research

2006

Publication first page
Document cover page
Click the image to enlarge

Measurement and sampling of diesel particulate matter in mine air presents a challenge due to the complexity of the diesel aerosol. The results of a series of tests carried out by the NIOSH Pittsburgh Research Laboratory in an underground mine were used to evaluate several measurement methods that are currently used to characterize particulate matter emitted by diesel-powered equipment. This paper presents an overview of these techniques and examples of the results, along with a discussion of the advantages and information gained by each technique. The measurement methods discussed include particle size measurements using a scanning mobility particle sizer, total particulate matter measurements using a tapered elemental oscillating microbalance, a size-selective sampling method for workplace and personal exposure assessment, and a size-selective high-volume sampling method for carbon analysis.

Author(s):Mischler-SE, Bugarski-AD, Noll-JD
Reference:In: Mutmansky JM, Ramani RV. eds. Proceedings of the 11th U.S./North American Mine Ventilation Symposium (University Park, PA, June 5-7, 2006). London, UK: Taylor & Francis Group; :99-104

   ifdpm (PDF, 572 KB)


A link above requires the Adobe Acrobat® Reader.
You can download a reader for free from Adobe through our Accessibility/Tools page.
Get Adobe Reader
Page last updated: September 17, 2008
Content Source: National Institute for Occupational Safety and Health (NIOSH) Mining Division