Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 1223.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 2183.0 | 1282.7 | 2208.0 |
Indicator value | 0.9 | 0.9 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned power changes | 1.0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 1223.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 2183.0 | 1282.7 | 2208.0 |
Indicator value | 1.8 | 1.8 | 0.9 | 0.9 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Scrams with Complications | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Safety System Functional Failures | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 8.90E-08 | 1.00E-07 | 7.40E-09 | 5.80E-08 | 2.00E-07 | 1.70E-07 | 7.40E-10 | -1.40E-09 |
URI (ΔCDF) | -6.30E-07 | -6.30E-07 | -6.30E-07 | -5.10E-07 | -1.60E-07 | -1.60E-07 | -1.60E-07 | 9.70E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -5.41E-07 | -5.30E-07 | -6.23E-07 | -4.52E-07 | 4.00E-08 | 1.00E-08 | -1.59E-07 | 9.56E-08 |
Licensee Comments:
3Q/08: Changed PRA Parameter(s). Planned Unavailability Baseline Data changed/verified.
3Q/08: Planned Unavailability Baseline Data changed/verified. Revised EDG surveillance run time due to a change in surveillance requirements.
2Q/08: Planned Unavailability Baseline data changed per NEI 99-02, effective 2nd qtr 2008
3Q/07: PRA model for Beaver Valley Unit 2 was changed effective April 2, 2007.
Mitigating Systems Performance Index, High Pressure Injection System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -8.50E-09 | -3.40E-09 | -9.40E-09 | -5.20E-09 | -6.00E-09 | -6.60E-09 | -6.20E-09 | -7.20E-09 |
URI (ΔCDF) | -5.80E-08 | -5.80E-08 | -5.80E-08 | -2.10E-08 | -2.10E-08 | -2.10E-08 | -2.10E-08 | -2.10E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -6.65E-08 | -6.14E-08 | -6.74E-08 | -2.62E-08 | -2.70E-08 | -2.76E-08 | -2.72E-08 | -2.82E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 3.30E-09 | 1.60E-09 | -4.30E-10 | -2.10E-09 | 2.50E-08 | 2.90E-08 | 2.90E-08 | 6.90E-08 |
URI (ΔCDF) | 3.00E-07 | 3.00E-07 | 3.00E-07 | 2.30E-07 | 2.30E-07 | 2.30E-07 | 2.30E-07 | 2.30E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.03E-07 | 3.02E-07 | 3.00E-07 | 2.28E-07 | 2.55E-07 | 2.59E-07 | 2.59E-07 | 2.99E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 6.60E-08 | 6.70E-08 | 7.00E-08 | 5.10E-08 | 5.10E-08 | 3.40E-08 | -2.40E-09 | -4.10E-09 |
URI (ΔCDF) | -9.00E-09 | -9.00E-09 | -9.00E-09 | -6.70E-09 | -6.70E-09 | -6.70E-09 | -6.70E-09 | -6.70E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 5.70E-08 | 5.80E-08 | 6.10E-08 | 4.43E-08 | 4.43E-08 | 2.73E-08 | -9.10E-09 | -1.08E-08 |
Licensee Comments:
3Q/08: Changed PRA Parameter(s). Planned Unavailability Baseline Data changed/verified.
Mitigating Systems Performance Index, Cooling Water Systems | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 1.70E-08 | 1.80E-08 | 1.80E-08 | 1.10E-08 | 1.10E-08 | 2.70E-08 | 5.90E-08 | 5.50E-08 |
URI (ΔCDF) | 2.10E-08 | 2.10E-08 | 2.10E-08 | 5.00E-08 | 5.00E-08 | 5.00E-08 | 5.00E-08 | 4.10E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.80E-08 | 3.90E-08 | 3.90E-08 | 6.10E-08 | 6.10E-08 | 7.70E-08 | 1.09E-07 | 9.60E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum activity | 0.000065 | 0.000239 | 0.000089 | 0.000095 | 0.000101 | 0.000106 | 0.000111 | 0.000140 | 0.000108 | 0.000142 | 0.000137 | 0.000138 |
Technical specification limit | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
Indicator value | 0 | 0.1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum activity | 0.000155 | 0.000149 | 0.000153 | 0.000156 | 0.000167 | 0.000168 | 0.000299 | 0.000067 | 0.000083 | 0.000099 | 0.000113 | 0.000115 |
Technical specification limit | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0.1 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum leakage | N/A | 0.060 | 0.090 | 0.080 | 0.120 | 0.080 | 0.070 | 0.080 | 0.080 | 0.080 | 0.080 | 0.070 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | N/A | 0.6 | 0.9 | 0.8 | 1.2 | 0.8 | 0.7 | 0.8 | 0.8 | 0.8 | 0.8 | 0.7 |
Reactor Coolant System Leakage | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum leakage | 0.090 | 0.080 | 0.090 | 0.080 | 0.120 | 0.080 | 0.080 | 0.070 | 0.070 | 0.070 | 0.060 | 0.060 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.9 | 0.8 | 0.9 | 0.8 | 1.2 | 0.8 | 0.8 | 0.7 | 0.7 | 0.7 | 0.6 | 0.6 |
Licensee Comments: none
Drill/Exercise Performance | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful opportunities | 31.0 | 15.0 | 26.0 | 16.0 | 22.0 | 15.0 | 30.0 | 24.0 |
Total opportunities | 33.0 | 16.0 | 27.0 | 16.0 | 23.0 | 17.0 | 34.0 | 27.0 |
Indicator value | 96.7% | 96.8% | 96.6% | 95.1% | 94.9% | 94.5% | 92.5% | 92.7% |
Licensee Comments: none
ERO Drill Participation | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Participating Key personnel | 123.0 | 124.0 | 122.0 | 120.0 | 122.0 | 131.0 | 131.0 | 129.0 |
Total Key personnel | 123.0 | 124.0 | 122.0 | 120.0 | 122.0 | 131.0 | 131.0 | 129.0 |
Indicator value | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful siren-tests | 119 | 118 | 119 | 235 | 119 | 119 | 119 | 237 |
Total sirens-tests | 119 | 119 | 119 | 238 | 119 | 119 | 119 | 238 |
Indicator value | 99.2% | 99.0% | 99.2% | 99.3% | 99.3% | 99.5% | 99.5% | 99.8% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: November 26, 2008