Title: Feasibility of fiberglass-reinforced bolted wood connections

Author: Windorski, D. F.; Soltis, L. A.; Ross, R. J.

Date: 

Source: (Research paper FPL ; RP-562):9 p. : ill. ; 28 cm.

Station ID: RP-FPL-562

Description: Bolted connections often fail by a shear plug or a splitting beneath the bolt caused by tension perpendicular-to-grain stresses as the bolt wedges its way through the wood. Preventing this type of failure would enhance the capacity and reliability of the bolted connection, thus increasing the overall integrity of a timber structure and enabling wood to compete favorably with other engineering materials. This research investigated the use of fiberglass reinforcement to enhance the load-carrying capacity of bolted wood connections. A series of specimens were prepared from standard 38- by 89-mm (nominal 2- by 4-in.) lumber from the Spruce1Pine1Fir lumber grouping. Matched specimens were reinforced with one, two, or three layers of bi-directional fiberglass cloth. Resulting test specimens were configured as a connection that was in accordance with current design specifications. A total of 80 single-bolt, double-shear connections were tested; 40 parallel to grain and 40 perpendicular to grain. Results indicate that connection strength increases as the layers of fiberglass reinforcement increase. The largest increase occurred when adding the first layer to the nonreinforced connection. Additional layers increased strength at a decreasing rate. The ultimate strength of a three-layer reinforced connection was 33 percent greater than the nonreinforced connection for parallel-to grain loading and more than 100 percent for perpendicular-to-grain loading. More importantly for parallel-to-grain loading, the reinforcement changed the mode of failure from an abrupt, catastrophic type associated with tension perpendicular-to-grain stresses to a ductile type associated with bearing stress.

Keywords: Bolted joints, Timber connectors, Fiberglass

View and Print this Publication (274 KB)

Publication Notes: 

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

Citation

Windorski, D. F.; Soltis, L. A.; Ross, R. J.  .  Feasibility of fiberglass-reinforced bolted wood connections .   (Research paper FPL ; RP-562):9 p. : ill. ; 28 cm..

US Forest Service - Research & Development
Last Modified:  January 24, 2013


USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.