Title: Correlation of smoke development in room tests with cone calorimeter data for wood products

Author: Dietenberger, Mark A.; Grexa, Ondrej.

Date: 2000

Source: [Proceedings: Wood & Fire Safety, 4th International Scientific Conference : May 14-19, 2000, Strbske Pleso, Slovak Republic. S.l. : s.n., 2000].:p. 45-55 : ill.

Description: A direct proportionality has been found between the smoke extinction area (SEA) for smoke of room linings and the SEA as measured in the cone calorimeter (ISO5660). The room test scenario (ISO9705) considered was the propane ignition burner at the corner with a 100/300 kW program and the specimen lined on the walls only. The mixing of smoke from propane and lining flames in the hot vitiated ceiling layer and within the exhaust system was modeled by adding contributions from heat release rates of propane and linings separately as a function of time. With overventilation and flaming generally existing in the room, the best correlation was a value of 0.3 for the ratio of lining SEA (= EHC*RSP1 /RHR1) to the peak SEA measured in the cone calorimeter of a horizontal specimen exposed to the flux of 35 kW/m2 during flaming. The test room linings in the order of increasing value of SEA were determined as plywood (including fire-retardant treated (FRT)), lumber, wood composite, and FRT polyurethane foam.

Keywords: Wood products, Smoke, Fire behavior, Fire danger, Calorimeters, Correlation

View and Print this Publication (122 KB)

Publication Notes: 

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

Citation

Dietenberger, Mark A.; Grexa, Ondrej.  2000.  Correlation of smoke development in room tests with cone calorimeter data for wood products .   [Proceedings: Wood & Fire Safety, 4th International Scientific Conference : May 14-19, 2000, Strbske Pleso, Slovak Republic. S.l. : s.n., 2000].:p. 45-55 : ill..

US Forest Service - Research & Development
Last Modified:  January 24, 2013


USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.