Safety and Health Topics: |
|
Phosgene |
|
General Description
Synonyms: Carbonyl chloride; Carbon oxychloride; Chloroformyl chloride
OSHA IMIS Code Number: 2070
Chemical Abstracts Service (CAS) Registry Number: 75-44-5
NIOSH, Registry of Toxic Effects (RTECS) Identification Number: SY5600000
Department of Transportation Regulation Number (49 CFR 172.101) and Guide: 1076 125
NIOSH Pocket Guide to Chemical Hazards, Phosgene: chemical description, physical properties, potentially hazardous incompatibilities, and more
Exposure Limits
OSHA Permissible Exposure Limit (PEL) for General Industry: 29 CFR 1910.1000 Z-1 Table -- 0.1 ppm, 0.4 mg/m3 TWA
OSHA Permissible Exposure Limit (PEL) for Maritime: 29 CFR 1915.1000 Table Z-Shipyards -- 0.1 ppm, 0.4 mg/m3 TWA
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 0.1 ppm, 0.4 mg/m3 TWA
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 0.1 ppm, 0.4 mg/m3 TWA; 0.2 ppm, 0.8 mg/m3 Ceiling (15 Minutes)
Health Factors
Environmental Protection Agency (EPA) carcinogenic classification: Group D, not classifiable as to human carcinogenicity
NIOSH Immediately Dangerous To Life or Health Concentration (IDLH): 2 ppm
Potential symptoms: Eye irritation; dry burning throat, choking; vomiting; coughing, foamy bloody sputum, dyspnea, chest pain; pulmonary edema, cyanosis; skin redness, burns; frostbite (liquid form)
Health Effects: Acute lung damage/edema (HE11); Cumulative lung damage-Emphysema, fibrosis (HE10); Irritation-Eyes, Skin---Marked (HE14).
Affected organs: Respiratory system, skin, eyes.
Date Last Revised: 07/09/2003
Literature Basis:
- (symptoms and IDLH)
U.S. EPA Technology Transfer Network Air Toxics Website: Technology Transfer Network Air Toxics Website: Phosgene.
- International Chemical Safety Cards (WHO/IPCS/ILO): Phosgene.
Monitoring Methods used by OSHA
Laboratory Sampling/Analytical Method:
sampling media: Coated XAD-2 Tube (150/75 mg sections, 20/60 mesh) Coated with 10% (w/w) 2-(Hydroxymethyl)piperidine. SOLVENT: Toluene
maximum volume: 240 Liters maximum flow rate: 1.0 L/min
minimum time: Minutes maximum flow rate:
current analytical method: Gas Chromatography; GC/NPD
method reference: OSHA Manual of Analytical Methods (OSHA 61)
method classification: Fully Validated
note: OSHA personnel may obtain sampling tube from SLTC. When relative humidity at sampling site is low, reduce maximum sample size to 120 Liters and sampling rate to 0.5 L/min.
On-Site Sampling Techniques/Methods:
device: Detector Tube
manufacturer: AUER/MSA
model/type: Phosgene-0.1, MSA P/N 803949, AUER P/N 5085-854
sampling information: follow manufacturer’s instructions
upper measurement limit: 20 ppm
detection limit: approx. 0.1 ppm
overall uncertainty: unknown
method reference: on-site air secondary (manufacturer)
device: Detector Tube
manufacturer: Dräger
model/type: Phosgene 0.02/a, order no. 81 01521
sampling information: 20 or 40 strokes
upper measurement limit: 1 ppm
detection limit: approx. 0.01 ppm
overall uncertainty: 16%
method reference: on-site air secondary (manufacturer)
device: Detector Tube
manufacturer: Dräger
model/type: Phosgene 0.05/a, order no. CH 19401
sampling information: 1 to 33 strokes
upper measurement limit: 1.5 ppm
detection limit: approx. 0.04 ppm
overall uncertainty: 32%
method reference: on-site air secondary (manufacturer)
device: Detector Tube
manufacturer: Dräger
model/type: Phosgene 0.25/a, order no. CH 28301
sampling information: 5 strokes
upper measurement limit: 5 ppm
detection limit: approx. 0.1 ppm
overall uncertainty: 25%
method reference: on-site air secondary (manufacturer)
device: Detector Tube
manufacturer: Gastec
model/type: 16
sampling information: 1 to 10 strokes
upper measurement limit: 20 ppm
detection limit: 0.01 ppm
overall uncertainty: 16% for 0.1 to 1 ppm, 8% for 1 to 5 ppm
method reference: on-site air secondary (manufacturer)
device: Detector Tube
manufacturer: Matheson-Kitagawa
model/type: 8014-146S
sampling information: follow manufacturer’s instructions
upper measurement limit: 20 ppm
detection limit: approx. 0.1 ppm
overall uncertainty: unknown
method reference: on-site air secondary (manufacturer)
* All Trademarks are the property of their respective owners.
|
|
Revised: 14 October 2003 |
|
|
|
|
|