skip to content
 
RXTE Guest Observer Faciliity

RXTE Absolute Timing Accuracy


NOTE: The time stamps present in RXTE FITS tables as generated by XFF are in TT.

Definition of Terms

To properly understand the various elements involved in establishing absolute time, one has to be aware of the different components and time systems. In the RXTE FITS files, one will find the following quantities, either as header keywords or table columns.

    Time         Time stamp, in MET seconds (i.e., the spacecraft clock reading)
    TIMEZERO     First order clock correction (~3.4 s)
    MJDREF       The MJD(TT) of 1994.0(UTC): 49353 d + 60.184 s
    TIMESYS      Time system; either TT or TDB
    CLOCKAPP     Boolean: any correction applied?
    TIERABSO     Absolute time accuracy
    TIMEPIXR     Relative position of time stamp in bin
    
Time systems:
    TT           Terrestrial Time
    TDB          Barycentric Dynamical Time
    TCG          Geocentric Coordinate Time
    TCB          Barycentric Coordinate Time
    
MET (Mission Elapsed Time) is counted as elapsed seconds since 1994.0 (UTC). MJD (Modified Julian Day) is defined as JD - 2400000.5. A more detailed description of time scales and time systems can be found in the RXTE Time Tutorial.

Time can be expressed in the following ways:

    MET (accuracy 4 s)      Time
    MET (accuracy 100 µs)   Time + TIMEZERO
    MET (accuracy 5 µs)     Time + TIMEZERO + clockCorr;
    MJD(UTC)                MET + 49353 d - leap seconds
    MJD(TT)                 MET + 49353 d + 60.184 s
    MJD(TDB)                TT + baryCorr(TDB) = TT + tau + (TDB - TT)
    MJD(TCB)                TT + baryCorr(TCB) = TT + tau + (TCG - TT) + (TCB - TCG)
    


MOC Clock Calibration

The MOC (Missions Operations Center) performs clock calibrations several times a day. It uses the USCCS method which involves tagging of a round-trip signal, claiming an accuracy of 1 µs, deteriorated to 5 µs by uncertainties in the White Sands ground clock.

For various reasons, we believe this technique to have yielded an accuracy of 8 µs for RXTE observations made prior to 1997-04-29 (mission day 1214). From that day onward, a formal accuracy of 5 µs is appropriate.


Scientific Verification

Using the pulsars PSR B1509-58 and PSR B0531+21 (the Crab pulsar), we have verified the MOC's absolute clock calibration to an accuracy of 1 ms. This the best that can be done, using cosmic sources. Hence, we feel justified in accepting the clock calibrations by the MOC to the quoted accuracy of 5 or 8 µs (see above).

In addition, the RXTE instruments have intrinsic delays which need to be included in high-precision clock corrections. These are:

    PCA:       16 - 20 µs
    HEXTE:      0 -  1 µs
    


Barycenter Corrections

The pathlength corrections (tau) applied by the Ftool fxbary are based on inherited software and ephemeris; they are accurate to better than 1 µs. (Note that raw times in the FITS files are only accurate to about 60 µs.) The pathlength correction calculation in fasebin uses new software, based more directly on the JPL DE-200 ephemeris, and including the fine clock corrections. It is accurate to a fraction of a µs.

The values for TDB-TT that these tools derive are not to be trusted to better than a few µs. However, if one were to improve on these, one should really switch from using TDB to TCB.


Clock Correction Tools

If an absolute timing accuracy of 100 µs is sufficient, the FITS files contain all that is needed, provided that CLOCKAPP is true and TIMEZERO is non-zero.

If one needs to do better than that, there are now three XTE-GOF tools that incorporate the higher accuracy:

    1. The Ftool fasebin automatically applies high-accuracy clock corrections, provided that it has access to a current version of the file tdc.dat.

    2. The web tool xTime always provides all clock corrections, whenever it does a time conversion.

    3. The Ftool faxbary (released with HEAsoft 5.0.4 patch) automatically applies high-accuracy clock corrections, provided that it has access to a current version of the file tdc.dat. It also takes account of the 16 µs instrumental delay in the PCA (whereas fxbary did not).

If one is using one's own software, one can obtain a C function that calculates the clock correction. xCC.c is available through the web.

All these tools rely on the same ASCII file, tdc.dat, which contains the clock correction coefficients and needs to be kept up-to-date.

An illustration of the magnitude of the clock correction as a function of time, over much of the RXTE mission lifetime, can be found on the Timing Digest Page.


Sampling and the Position of Time Stamps

In RXTE FITS files, three types of data are encountered:

    1. Integrated data.

    Also histogram or binned data. All science data (including event lists) belong to this category. A certain quantity, such as an event count, is integrated over a specific time range (bin). In binned modes, a histogram is presented with contiguous time bins. In event modes, individual time bins are enumerated, each with an implied event count of 1 and a width equal to the time resolution.

    The keyword TIMEPIXR indicates the relative position of the time stamp in the bins: a value of 0.0 indicates that the time stamp refers to the beginning of the bin; 0.5 the center of the bin; 1.0 the end of the bin. If TIMEPIXR is absent, a value of 0.5 is to be assumed, conform the FITS standard. RXTE FITS files always have TIMEPIXR=0.0; i.e., for RXTE, the time stamps always refer the the start of the bin.

    2. Sampled data with known sampling interval

    A physical quantity, like a voltage or a temperature, or a bit mask, such as a command, is sampled at regular, fixed, and known intervals. This is the case for housekeeping files (particularly instrument housekeeping files) that have a non-zero value for the keyword DELTAT. All that can be said is that the reading took place in the time interval of DELTAT seconds following the time stamp.

    3. Sampled data with unknown sampling interval

    A physical quantity, like a voltage or a temperature, or a bit mask, such as a command, is sampled at unknown intervals. This is the case for housekeeping files (particularly spacecraft housekeeping files) that have a zero value for the keyword DELTAT. All that can be said is that the reading took place in the time interval between the previous and the current time stamp. In retrospect, a value of 1.0 might have been more appropriate for TIMEPIXR, in this case.

In the last two cases, it may be possible to be more precise, but this requires detailed knowledge of the subsystem, as well as particulars of the data, and no general rule can be given.


If you have a question about RXTE, please send email to one of our help desks.

This page is maintained by the RXTE GOF and was last modified on Thursday, 19-Jul-2001 08:59:54 EDT.

Science Mission Directorate Universe Division
Beyond Einstein | Origins

Questions/Comments/Feedback
Download Adobe Acrobat
Learn about black holes, astronomy & more!

A service of the Astrophysics Science Division (ASD) at NASA/ GSFC

RXTE Project Scientist Jean Swank,
Responsible NASA Official: Phil Newman
Web Page Representive: Terri Shaffer

Privacy Policy and Important Notices.