Mercury Lamp Drum-Top Crusher Study
You will need Adobe Reader to view some of the files on this page. See EPA's PDF page to learn more.
Drum-top crushers (DTCs) are devices that fit on the top of a 55-gallon drum and crush fluorescent lamps into the drum; they are used to improve waste lamp storage and transport.
The Mercury Lamp Drum-Top Crusher Study provides the most current information on the performance of DTCs. The Study provides information on mercury emissions control effectiveness for DTCs. EPA believes that with the information from the Study, states, users of mercury-containing lamps, and lamp recyclers will be able to make more informed decisions when managing fluorescent lamps.
EPA does not to endorse or discourage the use of DTCs.
- Signed Cover Letter (PDF) [1 pg., 86 KB] - August 24, 2006
- Mercury Lamp Drum-Top Crusher Study (PDF) [102 pp., 1.1 MB, EPA 530-R-06-002]
- Appendix A: Air and Wipe Sample Results (PDF) [77 pp., 968 KB]
- Appendix B: Air Sampling Data Forms - Part 1 (PDF) [33 pp., 1,491KB]
- Appendix B: Air Sampling Data Forms - Part 2 (PDF) [35 pp., 1,678 KB]
- Appendix B: Air Sampling Data Forms - Part 3 (PDF) [50 pp., 2,508 KB]
- Appendix B: Air Sampling Data Forms - Part 4 (PDF) [29 pp., 1,436 KB]
- Appendix B: Air Sampling Data Forms - Part 5 (PDF) [33 pp., 1,739 KB]
- Appendix B: Air Sampling Data Forms - Part 6 (PDF) [34 pp., 1,597 KB]
- Appendix C: Data Chem Laboratory Reports - Part 1 (PDF) [10 pp., 540 KB]
- Appendix C: Data Chem Laboratory Reports - Part 2 (PDF) [9 pp., 798 KB]
- Appendix C: Data Chem Laboratory Reports - Part 3 (PDF) [10 pp., 263 KB]
- Appendix C: Data Chem Laboratory Reports - Part 4 (PDF) [27 pp., 685 KB]
- Appendix D: Drum Top Crushing Device Sampling and Study Plan (PDF) [22 pp., 152 KB]
- Appendix E: Laboratory Methods and Modifications (PDF) [8 pp., 78 KB]
- Appendix F: Wipe Sample Data and Discussion (PDF) [6 pp., 90 KB]
- Appendix G: Sampling Error and Correction Efforts for Mass Balance Study (PDF) [4 pp., 90 KB]
- Appendix H: Procedures for Collection of Samples from Pollution Control Media (PDF) [3 pp., 62 KB]
- Appendix I: Letter from EPA Documenting Problems with Manufacturer D Device (PDF) [12 pp., 716 KB]
- Appendix J: Peer Review of Mercury Lamp Drum-Top Study - Response to Comments (PDF) [66 pp., 364 KB]
Summary of NEWMOA States DTC Policies (PDF) [2 pp., 30 KB]