The grades of evidence (I-III) and levels of recommendations (A-C) are defined at the end of "Major Recommendations" field.
The following recommendation is based on good and consistent scientific evidence (Level A):
- First-trimester screening using both nuchal translucency measurement and biochemical markers is an effective screening test for Down syndrome in the general population. At the same false-positive rates, this screening strategy results in a higher Down syndrome detection rate than does the second-trimester maternal serum triple screen and is comparable to the quadruple screen.
- Measurement of nuchal translucency alone is less effective for first-trimester screening than is the combined test (nuchal translucency measurement and biochemical markers).
- Women found to have increased risk of aneuploidy with first-trimester screening should be offered genetic counseling and the option of chorionic villus sampling (CVS) or second-trimester amniocentesis.
- Specific training, standardization, use of appropriate ultrasound equipment, and ongoing quality assessment are important to achieve optimal nuchal translucency measurement for Down syndrome risk assessment, and this procedure should be limited to centers and individuals meeting these criteria.
- Neural tube defect screening should be offered in the second trimester to women who elect only first-trimester screening for aneuploidy.
The following recommendations are based on limited or inconsistent scientific evidence (Level B):
- Screening and invasive diagnostic testing for aneuploidy should be available to all women who present for prenatal care before 20 weeks of gestation regardless of maternal age. Women should be counseled regarding the differences between screening and invasive diagnostic testing.
- Integrated first- and second-trimester screening is more sensitive with lower false-positive rates than first-trimester screening alone.
- Serum integrated screening is a useful option in pregnancies where nuchal translucency measurement is not available or cannot be obtained.
- An abnormal finding on second-trimester ultrasound examination identifying a major congenital anomaly significantly increases the risk of aneuploidy and warrants further counseling and the offer of a diagnostic procedure.
- Patients who have a fetal nuchal translucency measurement of 3.5 mm or higher in the first trimester, despite a negative aneuploidy screen, or normal fetal chromosomes, should be offered a targeted ultrasound examination, fetal echocardiogram, or both.
- Down syndrome risk assessment in multiple gestation using first- or second-trimester serum analytes is less accurate than in singleton pregnancies.
- First-trimester nuchal translucency screening for Down syndrome is feasible in twin or triplet gestation but has lower sensitivity than first-trimester screening in singleton pregnancies.
The following recommendations are based primarily on consensus and expert opinion (Level C):
- After first-trimester screening, subsequent second-trimester Down syndrome screening is not indicated unless it is being performed as a component of the integrated test, stepwise sequential, or contingent sequential test.
- Subtle second-trimester ultrasonographic markers should be interpreted in the context of a patient's age, history, and serum screening results.
Definitions:
Grades of Evidence
I Evidence obtained from at least one properly designed randomized controlled trial.
II-1 Evidence obtained from well-designed controlled trials without randomization.
II-2 Evidence obtained from well-designed cohort or case–control analytic studies, preferably from more than one center or research group.
II-3 Evidence obtained from multiple time series with or without the intervention. Dramatic results in uncontrolled experiments also could be regarded as this type of evidence.
III Opinions of respected authorities, based on clinical experience, descriptive studies, or reports of expert committees.
Levels of Recommendation
Level A — Recommendations are based on good and consistent scientific evidence.
Level B — Recommendations are based on limited or inconsistent scientific evidence.