Important Information for OMI Data Users
Row Anomalies
Several row anomalies have occurred in the recent past. These anomalies affect the quality of the Level 1B and Level 2 data products. Please read this information carefully prior to using OMI data. Please respect the dates mentioned as the anomalies have occurred recently.
Anomaly 1: Since June 25th, 2007, cross-track scenes 53-54 (0-based).
Anomaly 2: Since May 11th, 2008, cross-track scenes 37-44 (0-based)
Anomaly 3: Since January 24th, 2009, cross-track scenes 27-44 (0-based).
Please be aware that for all other rows the data are of optimal quality and not affected.
Also all OMI data before these anomalies are of optimal quality.
Row Anomaly Corrections
Please be aware that these anomalies are known to the OMI team and are currently under investigation to examine whether corrections for the effects can be implemented in the Level 1b data. Please visit this information page regularly for updates on the status of corrections implemented and visit our detailed technical information page.
Row Anomaly Flagging
The Level 1B data are partially flagged for the anomalies listed above. Please visit our detailed technical information page for details on the current flagging status of the Level 1B and Level 2 products.
Recommendations To Users
At the moment no corrections have been implemented in the operational Level 1B and Level 2 data. It is recommended not to use the affected cross-track scenes.
Please respect the dates mentioned above. All other OMI data, meaning other cross track scenes and earlier observations, is of optimal quality.
Level-3 products are being produced after filtering for the cross track scenes mentioned per anomaly. |