Clinical Trial of a Computer-Driven Weaning System for Patients Requiring Mechanical Ventilation
This study is enrolling participants by invitation only.
First Received: January 3, 2008   Last Updated: January 22, 2008   History of Changes
Sponsored by: Boston Medical Center
Information provided by: Boston Medical Center
ClinicalTrials.gov Identifier: NCT00606554
  Purpose

The purpose of this study is to compare the efficacy of a computer-assisted ventilator weaning system (Drager Smartcare) to our current standard of care in the medical intensive care unit.


Condition Intervention
Respiratory Insufficiency
Device: Computer-driven weaning program - Drager Evita Smartcare System
Behavioral: Standard of Care weaning

Study Type: Interventional
Study Design: Treatment, Randomized, Open Label, Active Control, Parallel Assignment, Efficacy Study
Official Title: A Randomized Controlled Trial of Computer-Driven Weaning Compared With Standard of Care Weaning in Medical Patients Requiring Mechanical Ventilation

Further study details as provided by Boston Medical Center:

Primary Outcome Measures:
  • Duration of Weaning [ Time Frame: duration of study ] [ Designated as safety issue: No ]

Secondary Outcome Measures:
  • Duration of ICU stay [ Time Frame: duration of study ] [ Designated as safety issue: No ]
  • Duration of mechanical ventilation [ Time Frame: duration of study ] [ Designated as safety issue: No ]
  • Duration of hospitalization [ Time Frame: duration of study ] [ Designated as safety issue: No ]
  • Mortality [ Time Frame: 28 days ] [ Designated as safety issue: No ]
  • Sedation requirements [ Time Frame: duration of study ] [ Designated as safety issue: No ]
  • Number of spontaneous breathing trials prior to extubation [ Time Frame: duration of study ] [ Designated as safety issue: No ]
  • Complications (mortality during wean, ventilator-associated pneumonia, self extubation, re-intubation rate) [ Time Frame: duration of study ] [ Designated as safety issue: Yes ]

Estimated Enrollment: 220
Study Start Date: January 2008
Estimated Study Completion Date: March 2009
Estimated Primary Completion Date: March 2009 (Final data collection date for primary outcome measure)
Arms Assigned Interventions
Computer-assisted wean: Experimental
Group assigned to the computer-assisted weaning program
Device: Computer-driven weaning program - Drager Evita Smartcare System
Closed-loop, knowledge-based, computer driven weaning program initiated at the start of ventilator weaning.
Standard of Care: Active Comparator
Group assigned to receive current, evidence-based, standard of care for discontinuation of mechanical ventilation.
Behavioral: Standard of Care weaning
Evidence-based standard of care weaning process.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • Age greater than 18 years
  • Initiated on mechanical ventilation via endotracheal tube
  • Admitted to Medical Intensive Care Unit and MICU Team (Harrison Avenue Campus, Menino Pavilion)
  • Requiring mechanical ventilation for more than 48 hours
  • Meets prespecified weaning criteria

Exclusion Criteria:

  • DNR/DNI order
  • Pregnancy
  • Mechanical ventilation initiated at another hospital
  • Cardiac arrest for more than 5 minutes with poor neurologic prognosis
  • Tracheostomy
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT00606554

Locations
United States, Massachusetts
Boston Medical Center
Boston, Massachusetts, United States, 02118
Sponsors and Collaborators
Boston Medical Center
Investigators
Principal Investigator: Christine C Reardon, MD Boston University
  More Information

Additional Information:
No publications provided

Responsible Party: Boston University Medical Center ( Christine Reardon, MD )
Study ID Numbers: H-26906
Study First Received: January 3, 2008
Last Updated: January 22, 2008
ClinicalTrials.gov Identifier: NCT00606554     History of Changes
Health Authority: United States: Institutional Review Board

Keywords provided by Boston Medical Center:
Respiratory Insufficiency
Ventilators, Mechanical
Ventilator Weaning
Therapy, Computer-Assisted
Ventilators, Mechanical
Ventilator Weaning
Therapy, Computer-Assisted

Study placed in the following topic categories:
Respiratory Insufficiency
Respiratory Tract Diseases
Respiration Disorders

Additional relevant MeSH terms:
Respiratory Insufficiency
Respiratory Tract Diseases
Respiration Disorders

ClinicalTrials.gov processed this record on September 03, 2009