Study to Verify Proper Detection of Supraventricular Tachyarrhythmia With Single-Lead Dual-Chamber Implantable Cardioverter-Defibrillators (ADRIA)
This study has been completed.
First Received: May 10, 2006   Last Updated: September 29, 2008   History of Changes
Sponsored by: Biotronik SE & Co. KG
Information provided by: Biotronik SE & Co. KG
ClinicalTrials.gov Identifier: NCT00324662
  Purpose

A unique single-lead dual-chamber implantable cardioverter-defibrillator (ICD) system (produced by Biotronik, Germany) features a conventional electrode in the ventricle (anchored in the ventricular apex) and a floating electrode (ring on the lead body) in the atrium, capable of sensing atrial electrical signals. The purpose of this study is to determine whether this system detects a supraventricular tachyarrhythmia (e.g. atrial fibrillation, atrial tachycardia) in the equivalent manner as conventional dual-lead dual-chamber ICDs using two separate electrodes anchored in the ventricle and in the atrium, respectively.


Condition Intervention Phase
Tachyarrhythmia
Device: Implantable cardioverter-defibrillator
Phase IV

Study Type: Interventional
Study Design: Treatment, Randomized, Open Label, Active Control, Parallel Assignment, Safety/Efficacy Study
Official Title: ADRIA - Belos A+ vs DR Clinical Investigation of Arrhythmia Discrimination

Resource links provided by NLM:


Further study details as provided by Biotronik SE & Co. KG:

Primary Outcome Measures:
  • Rate of correctly discriminated supraventricular tachyarrhythmia episodes (specificity)

Secondary Outcome Measures:
  • Complication rate (e.g. lead dislocation, lead fracture)
  • Duration of implantation
  • Electrode performance (P-/R-wave amplitudes, ventricular pacing threshold and impedance)
  • Sensitivity (rate of correctly discriminated episodes of ventricular fibrillation or ventricular tachycardia)

Estimated Enrollment: 260
Study Start Date: August 2003
Study Completion Date: July 2008
Primary Completion Date: July 2008 (Final data collection date for primary outcome measure)
Detailed Description:

Supraventricular tachyarrhythmia (SVT) is the main cause of inappropriate therapy in patients with single-chamber implantable cardioverter-defibrillators (ICDs). To minimize inappropriate shock delivery, ICDs should sense both atrial and ventricular intracardiac signals. Dual-chamber ICDs are used for this purpose, but are associated with increased postoperative complications due to the implantation of a separate atrial lead. It has to be shown that a novel single-lead dual-chamber ICD-system with enhanced SVT discrimination can achieve the same specificity in discriminating SVT episodes as conventional dual-chamber ICD, without the disadvantage of the implantation of several leads. In this study patients eligible for dual-chamber ICD therapy who do not need atrial pacing will receive either a single-lead dual-chamber ICD (Belos A+ and Kainox A+ electrode) or a dual-lead dual-chamber ICD (Belos DR). SMART detection algorithm will be used in both study groups for discrimination between atrial and ventricular tachyarrhythmias. Atrial tachyarrhythmia episodes are facultatively induced in both groups at implantation or predischarge via a bipolar stimulation catheter. Induced episodes and the corresponding ICD intervention (detection and therapy or inhibition of therapy) are documented. Follow-ups are scheduled for 1, 3, 6 and 12 months after implantation. ICD intervention, particularly related to spontaneous SVT episodes, will be evaluated based on ICD diagnostic memory data interrogated at follow-up controls.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • ICD indication according to American College of Cardiology/American Heart Association (ACC/AHA) guidelines.
  • Informed consent

Exclusion Criteria:

  • Permanent atrial fibrillation
  • Requirement for atrial pacing
  • Patient is underage
  • No signed patient agreement
  • Patient life expectancy under 6 months
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT00324662

Locations
Germany
Westfälische Wilhelms-Universität
Münster, Germany, 48129
Medizinische Hochschule Hannover
Hannover, Germany, 30625
St. Johannes Hospital, Medizinische Klinik I
Dortmund, Germany, 44137
Sana Klinikum Lichtenberg
Berlin, Germany, 10365
Vivantes Netzwerk für Gesundheit GmbH (Humboldt)
Berlin, Germany, 13437
Charité-Universitätsmedizin Campus Benjamin Franklin, Med. Klinik II / Kardiologie
Berlin, Germany, 12200
Klinikum der Stadt Villingen Schwenningen GmbH
Villingen, Germany, 78050
Georg-August-Universität, Universitätsklinikum Göttingen
Goettingen, Germany, 37099
Kardiologische Praxis
Bonn, Germany, 53115
Switzerland
Kantonspital Basel, Abteilung für Kardiologie
Basel, Switzerland, 4031
Sponsors and Collaborators
Biotronik SE & Co. KG
Investigators
Principal Investigator: Michael Niehaus, Prof. Dr. Med. Medizinische Hochschule Hannover, Abt. Kardiologie, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
  More Information

No publications provided

Study ID Numbers: TA044
Study First Received: May 10, 2006
Last Updated: September 29, 2008
ClinicalTrials.gov Identifier: NCT00324662     History of Changes
Health Authority: Germany: Federal Institute for Drugs and Medical Devices

Keywords provided by Biotronik SE & Co. KG:
Implantable cardioverter-defibrillator
Ventricular tachyarrhythmia
Supraventricular tachyarrhythmia
Electric Countershock

Study placed in the following topic categories:
Heart Diseases
Tachycardia
Tachycardia, Ventricular
Arrhythmias, Cardiac

Additional relevant MeSH terms:
Pathologic Processes
Heart Diseases
Tachycardia
Cardiovascular Diseases
Arrhythmias, Cardiac

ClinicalTrials.gov processed this record on September 01, 2009